TP-Link SG3428XMPP Omada 24-Port Gigabit and 4-Port 10GE SFP+ L2+ Managed Switch with 16-Port PoE+ & 8-Port PoE++
Power and Efficiency for Advanced Networking The TP-Link SG3428XMPP Omada 24-Port Gigabit and 4-Port 10GE SFP+ L2+ Managed Switch is a versatile and powerful solution...
Power and Efficiency for Advanced Networking
The TP-Link SG3428XMPP Omada 24-Port Gigabit and 4-Port 10GE SFP+ L2+ Managed Switch is a versatile and powerful solution designed to enhance network performance and efficiency. With extensive PoE support and centralized management, this switch is ideal for businesses seeking to upgrade their network infrastructure with advanced features and robust capabilities.
Highlights
- High Power PoE Support: 16 PoE+ ports and 8 PoE++ ports with a total PoE budget of 500W
- High-Speed Connectivity: 4× 10 Gbps SFP+ slots for fast data transfer
- Centralized Management: Manage via web, CLI, SNMP, RMON, and the Omada app
Key Features
-
Robust PoE Capabilities
- 8 PoE++ Ports: Each port supports up to 90W, perfect for high-power devices like PTZ HD IP cameras with heaters and smart building lighting
- 16 PoE+ Ports: Each port supports up to 30W, suitable for access points, thin clients, and more
- 500W Total PoE Budget: Ample power for all connected devices
-
Advanced Networking Features
- Static Routing: Efficiently routes internal traffic for enhanced network performance
- VLAN, ACL, QoS, IGMP Snooping: Comprehensive network management and security features
- ERPS Support: Provides rapid protection and recovery in a ring topology
-
Flexible Management Options
- Centralized Cloud Management: Easily manage multiple sites through a single interface via the web or Omada app
- Standalone Management: Options include web interface, CLI, SNMP, and RMON
-
Durable and Versatile Design
- Metal Casing: Ensures durability and long-lasting performance
- Rack-Mountable: Easy to integrate into existing network infrastructure
Specifications
Specification | Details |
---|---|
Ports | 24× Gigabit RJ45 Ports (8× PoE++, 16× PoE+) |
4× 10 Gbps SFP+ Slots | |
PoE Budget | 500W Total PoE Budget |
PoE++ Port Budget | Max 90W per PoE++ Port |
PoE+ Port Budget | Max 30W per PoE+ Port |
Standards Compliance | IEEE 802.3af/at/bt, IEEE 802.3an, IEEE 802.3ae, IEEE 802.3aq |
Management Options | Centralized cloud management, standalone management via web, CLI, SNMP, RMON |
Advanced Features | Static Routing, VLAN, ACL, QoS, IGMP Snooping, OAM, DDM, ERPS |
Construction | Durable metal casing, rack-mountable design |
Dimensions | To be specified based on product dimensions |
Certifications | FCC, CE, RoHS |
Summary
The TP-Link SG3428XMPP Omada 24-Port Gigabit and 4-Port 10GE SFP+ L2+ Managed Switch is designed to provide high power and performance for advanced network setups. With a substantial PoE budget, high-speed connectivity, and flexible management options, this switch is perfect for businesses looking to enhance their network infrastructure with robust, scalable, and efficient solutions.
TP-Link SG3428XMPP Omada 24-Port Gigabit and 4-Port 10GE SFP+ L2+ Managed Switch with 16-Port PoE+ & 8-Port PoE++ Specifications
HARDWARE FEATURES | |
---|---|
Interface | 24× 10/100/1000 Mbps RJ45 Ports (8× PoE++, 16× PoE+), 4× 10G SFP+ Slots, 1× RJ45 Console Port, 1× Micro-USB Console Port |
Fan Quantity | 2 |
Physical Security Lock | √ |
Power Supply | 100-240 V AC~50/60 Hz |
PoE Ports (RJ45) | Standard: 802.3at/af/bt compliant, PoE++ Ports: Ports 1 |
Dimensions (W x D x H) | 17.3×13.0×1.7 in (440×330×44 mm) |
Mounting | Rack Mountable |
Max Power Consumption | 486.2 W (110V/60Hz) (with 384 W PD connected) |
Max Heat Dissipation | 1658.78 BTU/hr (110 V/60 Hz) (with 384 W PD connected) |
PERFORMANCE | |
Switching Capacity | 128 Gbps |
Packet Forwarding Rate | 95.23 Mpps |
MAC Address Table | 16 K |
Packet Buffer Memory | 12 Mbit |
Jumbo Frame | 9 KB |
SOFTWARE FEATURES | |
Quality of Service | 8 priority queues, 802.1p CoS/DSCP priority, Queue scheduling: SP (Strict Priority), WRR (Weighted Round Robin), SP+WRR, Bandwidth Control: Port/Flow-based Rating Limiting, Smoother Performance, Action for Flows: QoS remark (802.1P Remark, DSCP Remark) |
L2 and L2+ Features | 128 IP Interfaces: Support IPv4/IPv6 Interface, Static Routing: 48 IPv4/IPv6 Static Routes, Static ARP: 128 static entries, 512 ARP Entries, Proxy ARP, Gratuitous ARP, DHCP Server, DHCP Relay: DHCP Interface Relay, DHCP VLAN Relay, DHCP L2 Relay, Link Aggregation, Spanning Tree Protocol, Loopback Detection, 802.3x Flow Control, Mirroring |
L2 Multicast | Supports 1000 (IPv4, IPv6) IGMP groups, IGMP Snooping, IGMP Authentication, Multicast VLAN Registration (MVR), MLD Snooping, Multicast Filtering: 256 profiles and 16 entries per profile |
Advanced Features | Automatic Device Discovery†, Batch Configuration†, Batch Firmware Upgrading†, Intelligent Network Monitoring†, Abnormal Event Warnings†, Unified Configuration†, Reboot Schedule†, ISP Features: L2PT (Layer 2 Protocol Tunneling), Device Link Detect Protocol (DLDP), PPPoE ID Insertion, ERPS, 802.3ah Ethernet Link OAM, DDM, sFlow |
VLAN | VLAN Group: Max 4K VLAN Groups, 802.1q Tagged VLAN, MAC VLAN: 30 Entries, Protocol VLAN: Protocol Template 16, Protocol VLAN 16, Private VLAN, GVRP, VLAN VPN: VLAN Mapping, VLAN Replace, Voice VLAN |
Access Control List | Time-based ACL, MAC ACL: Source MAC, Destination MAC, VLAN ID, User Priority, Ether Type, IP ACL: Source IP, Destination IP, Fragment, IP Protocol, TCP Flag, TCP/UDP Port, DSCP/IP TOS, Combined ACL, Packet Content ACL, IPv6 ACL, Policy: Mirroring, Redirect, Rate Limit, QoS Remark, ACL applies to Port/VLAN |
Security | IP-MAC-Port Binding: 512 Entries, DHCP Snooping, ARP Inspection, IPv4 Source Guard: 100 Entries, IPv6-MAC-Port Binding: 512 Entries, DHCPv6 Snooping, ND Detection, ND Snooping, IPv6 Source Guard: 100 Entries, DoS Defend, DHCP Filter, Static/Dynamic Port Security: Up to 64 MAC addresses per port, Broadcast/Multicast/Unicast Storm Control: kbps/ratio/pps control mode, 802.1X: Port-based authentication, Mac-base authentication, VLAN Assignment, MAB, Guest VLAN, Radius authentication and accountability support, AAA (including TACACS+), Port Isolation, Secure web management through HTTPS with SSLv3/TLS 1.2, Secure Command Line Interface (CLI) management with SSHv1/SSHv2, IP/Port/MAC-based access control |
IPv6 | IPv6 Dual IPv4/IPv6, Multicast Listener Discovery (MLD) Snooping, IPv6 ACL, IPv6 Interface, Static IPv6 Routing, IPv6 neighbor discovery (ND), Path maximum transmission unit (MTU) discovery, Internet Control Message Protocol (ICMP) version 6, TCPv6/UDPv6, IPv6 applications: DHCPv6 Client, Ping6, Tracert6, Telnet (v6), IPv6 SNMP, IPv6 SSH, IPv6 SSL, Http/Https, IPv6 TFTP |
MIBs | MIB II (RFC1213), Interface MIB (RFC2233), Ethernet Interface MIB (RFC1643), Bridge MIB (RFC1493), P/Q-Bridge MIB (RFC2674), RMON MIB (RFC2819), RMON2 MIB (RFC2021), Radius Accounting Client MIB (RFC2620), Radius Authentication Client MIB (RFC2618), Remote Ping, Traceroute MIB (RFC2925), Support TP-Link private MIB |
MANAGEMENT | |
Omada App | Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller. |
Centralized Management | Omada Cloud-Based Controller, Omada Hardware Controller, Omada Software Controller |
Cloud Access | Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller. |
Zero-Touch Provisioning | Yes. Requiring the use of Omada Cloud-Based Controller. |
Management Features | Web-based GUI, Command Line Interface (CLI) through console port, telnet, SNMPv1/v2c/v3: Trap/Inform, RMON (1, 2, 3, 9 groups), SDM Template, DHCP/BOOTP Client, 802.1ab LLDP/LLDP-MED, DHCP AutoInstall, Dual Image, Dual Configuration, CPU Monitoring, Cable Diagnostics, EEE, Password Recovery, SNTP, System Log |
OTHERS | |
Certification | CE, FCC |
Package Contents | SG3428XMPP Switch, Power Cord, Quick Installation Guide, Rackmount Kit, Rubber Feet |
System Requirements | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux. |
Environment | Operating Temperature: 0–45 ℃ (32–113 ℉), Storage Temperature: -40–70 ℃ (-40–158 ℉), Operating Humidity: 10–90% RH non-condensing, Storage Humidity: 5–90% RH non-condensing |