Tough Outdoor Push-to-Exit Door Release Button
Clean Outdoor Access Control for Gates and Entrances The Tough Outdoor Push-to-Exit Door Release Button provides a clear, dedicated control point for compatible automated gates...
Clean Outdoor Access Control for Gates and Entrances
The Tough Outdoor Push-to-Exit Door Release Button provides a clear, dedicated control point for compatible automated gates and door access systems. Its broad PRESS paddle, neutral grey enclosure and concealed wiring keep the installation straightforward and unobtrusive. Pressing the paddle closes a normally open contact; releasing it returns the button to its original position.
Highlights
Simple, Tactile Operation
- Broad paddle with a clearly visible PRESS marking.
- Momentary action with automatic return after release.
- Wired mechanical operation with no separate power supply or battery required for the button.
NO/COM Controller Connection
- Normally open dry-contact output for compatible controller inputs.
- Single-pole single-throw (SPST) switch action.
- Supplier-stated maximum contact current of 20 A and maximum contact voltage of 250 VAC.
Outdoor Surface-Mount Enclosure
- Grey 90 × 90 × 55 mm enclosure with a sealing gasket and screw-secured cover.
- IP66 protection rating shown on the supplier packaging, with a UV-resistant housing.
- Separate mounting base and side cable-entry positions.
Key Features
A Clear Control Point at the Entrance
The large paddle provides an obvious place to press when entering or leaving. Its restrained grey finish and square enclosure suit gate pillars, external walls and service entrances without adding a visually busy control panel.
Automatic Return for Momentary Control
The contact closes only while the paddle is pressed and opens again when released. The connected controller determines whether that signal opens, closes or stops the gate, or releases a door. Compatibility depends on the controller accepting a normally open dry-contact push-button input.
No Separate Power Supply for the Button
The mechanical switch operates through its wired contact connection. It does not require a battery or a dedicated power supply. The gate operator or access controller retains its own power requirements.
Defined Electrical Contacts
The supplier identifies NO/COM output, with COM and L1 used in the wiring illustration. The stated 20 A maximum contact current and 250 VAC maximum contact voltage describe the switch contacts, not a required power supply. For gate and access-control use, connect to the controller's designated push-button input in accordance with its installation instructions.
IP66 Outdoor Enclosure
The original supplier packaging identifies the enclosure as IP66. The gasket between the base and cover, screw-secured construction and enclosed wiring suit outdoor control points beside gates and external entrances. Maintain the seals and use suitable cable entries during installation to preserve the enclosure's protection.
Practical Mounting and Wiring
The enclosure separates into a mounting base and front cover, with a gasket between them. Fix the base to a clean, solid and flat surface, route the signal cable and refit the cover with the seal correctly seated. The supplier photos show an instruction leaflet, screws and sealing plugs with the unit. Use fixings appropriate for the mounting surface. A two-core connection cable is required and is not included, according to the supplied wiring illustration.
Summary
The Tough Outdoor Push-to-Exit Door Release Button combines a broad PRESS paddle, automatic return and a supplier-rated IP66 enclosure with a straightforward NO/COM connection. It is a practical manual control for gates and doors whose controllers accept a normally open momentary input.
Tough Outdoor Push-to-Exit Door Release Button
The Tough Outdoor Push-to-Exit Door Release Button is a wired mechanical switch for compatible automated gates and door access systems. Its broad PRESS paddle operates a normally open dry contact and returns automatically when released. The button requires no separate power supply. A grey surface-mount enclosure, sealing gasket and screw-secured cover support outdoor installation. The specifications below distinguish the supplier-stated switch contact limits from the electrical requirements of the connected gate operator or access controller.
| Specification | Details |
|---|---|
| Operation and Electrical | |
| Product type | Manual outdoor push-to-exit / gate control button |
| Activation | Mechanical PRESS paddle |
| Switch action | Momentary; automatic return when released |
| Switch configuration | Single pole, single throw (SPST) |
| Output contacts | NO / COM; normally open dry contact |
| Contact behaviour | Open at rest; closes while pressed; opens on release |
| Terminals used | COM and L1, as shown in the supplier wiring illustration |
| Maximum contact current | 20 A, supplier-stated switch contact limit |
| Maximum contact voltage | 250 VAC, supplier-stated switch contact limit |
| Button power requirement | No separate power supply or battery required |
| Controller compatibility | Designated push-button input accepting a normally open dry-contact signal |
| Controlled action | Gate opening, closing or stopping, or door release, as configured by the connected controller |
| Enclosure and Installation | |
| Colour | Grey |
| Dimensions (H × W × D) | 90 × 90 × 55 mm |
| Mounting | Surface mount on a clean, solid and flat surface |
| Construction | Separate mounting base and screw-secured front cover |
| Seal | Gasket between the base and cover |
| Cable entry | Side cable-entry positions |
| Connection cable | Two-core signal cable, approximately 0.3 mm² per conductor (22 AWG), as specified in the supplier illustration; follow the controller's cable requirements |
| Cable included | No, according to the supplied wiring illustration |
| Accessories shown in supplier photos | Instruction leaflet, screws and sealing plugs |
| Wall fixings | Select fixings suitable for the mounting surface |
| Outdoor Use | |
| Ingress protection | IP66, as marked on the original supplier packaging |
| Weather resistance | Weather-resistant enclosure, as described by the supplier |
| UV resistance | UV-resistant housing, as described by the supplier |
| Operating temperature | Approximately −18 to 49°C, converted from the supplier-stated range |