D-Link DIS-100G-06P 6-Port Gigabit Industrial Unmanaged PoE+ Switch
Reliable Connectivity Beyond the Office The DIS-100G-06P connects equipment in industrial cabinets, production areas and protected surveillance installations. 4 Gigabit Ethernet ports and two Gigabit SFP slots provide a practical mix of local copper connections and separately specified fibre links. Its fanless metal enclosure mounts on a DIN rail and supports operation from −40°C to 75°C. Four PoE+ ports supply up to 30W each within a 120W shared budget. Plug-and-play unmanaged operation keeps straightforward network extensions simple without introducing a switch-management interface. Highlights Industrial Connectivity 4 × 10/100/1000BASE-T PoE+ and 2 × Gigabit SFP slots. 12 Gbps switching capacity and up to 8.92 Mpps forwarding. Fanless DIN-rail design for industrial cabinets. Power and Installation Dual 48–55 V DC terminal-block inputs; suitable DC power supply required separately. Up to 120W shared PoE+ power and 30W per powered port. IP40 metal housing and −40°C to 75°C operating range. Network Operation Unmanaged operation without software configuration. 6kV surge protection on copper Ethernet ports. 5-year warranty. Key Features Built for Equipment Cabinets A fanless enclosure avoids a cooling fan as an additional maintenance point. The specified −40°C to 75°C operating range supports installations beyond a temperature-controlled office. The IP40 rating is not a weatherproof outdoor rating: install the switch inside a suitable enclosure with the required grounding, ventilation and protection from water. Copper Access With Fibre Reach 4 Gigabit copper ports connect local equipment while two SFP slots provide fibre connection choices. Select compatible transceivers, fibre type, wavelength and distance for both ends of the link. The slots operate at Gigabit speed; they are not 10GbE uplinks, and optical modules are purchased separately. Plan the Power System Dual 48–55 V DC terminal-block inputs allow two suitable external power sources to be connected for redundancy. A power supply is not included. Size the supply for the switch and the intended PoE load, allowing appropriate headroom and temperature derating. Installation and protective grounding should follow the manufacturer instructions. Power Devices Over the Network IEEE 802.3af/at support provides up to 30W per powered port within the shared 120W budget. Add the actual endpoint requirements rather than multiplying the maximum port rating by every port. Sufficient DC input power and suitable cabling are required; available power at the device also depends on the Ethernet standard and cable losses. Connect Without Configuration Unmanaged operation lets a straightforward network extension start without switch configuration. Auto MDI/MDIX and auto-negotiation simplify compatible copper connections. Keep the topology free of accidental loops and provide network segmentation upstream when needed; this model does not replace the policy controls of a managed switch. A Practical Industrial Installation A compact DIN-rail installation suits organised equipment cabinets. Visible power and port indicators help with on-site checks, while Energy-Efficient Ethernet reduces consumption when compatible links are lightly used. Keep access to the terminals and fibre connections clear, and select cables and transceivers rated for the actual site conditions. Summary The DIS-100G-06P is a compact industrial unmanaged switch for dependable Gigabit access with PoE+ power. Specify the DC supply, optics and protective installation alongside the switch so the complete network is ready for its environment. Frequently Asked Questions Is a Power Supply Included?ExpandCollapse No. This offer requires a separate suitable 48–55 V DC DC power supply. The source must cover the intended PoE load as well as the switch, with appropriate installation headroom. Does This Switch Power Cameras or Access Points?ExpandCollapse Yes, compatible IEEE 802.3af/at devices can use the 4 powered copper ports, with up to 30W per port and a 120W shared budget. Can It Be Installed Outdoors?ExpandCollapse Use it inside a suitable protective cabinet. The IP40 enclosure is not weatherproof. The installation must meet the specified temperature and humidity conditions and include appropriate grounding. Are the Fibre Modules Included?ExpandCollapse No. The two Gigabit SFP slots accept separately selected compatible transceivers. Match fibre type, wavelength, distance and environmental rating at both ends. Can I Configure VLANs and Redundant Links?ExpandCollapse This is an unmanaged switch without a configuration interface. Use suitable managed equipment upstream for VLAN policy and avoid accidental cable loops. What Does Dual Power Input Mean?ExpandCollapse Two suitable 48–55 V DC supplies can be wired to the terminal inputs so one source can sustain operation if the other fails. The supplies are purchased separately and must be correctly rated for the complete load.
Add-ons (1)
Pickup available at 3005, Ubi Avenue 3, #01-88
Usually ready in 2-4 Business Day (Excluding Public Holiday)
D-Link DIS-100G-06P 6-Port Gigabit Industrial Unmanaged PoE+ Switch
Description
Reliable Connectivity Beyond the Office
The DIS-100G-06P connects equipment in industrial cabinets, production areas and protected surveillance installations. 4 Gigabit Ethernet ports and two Gigabit SFP slots provide a practical mix of local copper connections and separately specified fibre links. Its fanless metal enclosure mounts on a DIN rail and supports operation from −40°C to 75°C.
Four PoE+ ports supply up to 30W each within a 120W shared budget. Plug-and-play unmanaged operation keeps straightforward network extensions simple without introducing a switch-management interface.
Highlights
Industrial Connectivity
- 4 × 10/100/1000BASE-T PoE+ and 2 × Gigabit SFP slots.
- 12 Gbps switching capacity and up to 8.92 Mpps forwarding.
- Fanless DIN-rail design for industrial cabinets.
Power and Installation
- Dual 48–55 V DC terminal-block inputs; suitable DC power supply required separately.
- Up to 120W shared PoE+ power and 30W per powered port.
- IP40 metal housing and −40°C to 75°C operating range.
Network Operation
- Unmanaged operation without software configuration.
- 6kV surge protection on copper Ethernet ports.
- 5-year warranty.
Key Features
Built for Equipment Cabinets
A fanless enclosure avoids a cooling fan as an additional maintenance point. The specified −40°C to 75°C operating range supports installations beyond a temperature-controlled office. The IP40 rating is not a weatherproof outdoor rating: install the switch inside a suitable enclosure with the required grounding, ventilation and protection from water.
Copper Access With Fibre Reach
4 Gigabit copper ports connect local equipment while two SFP slots provide fibre connection choices. Select compatible transceivers, fibre type, wavelength and distance for both ends of the link. The slots operate at Gigabit speed; they are not 10GbE uplinks, and optical modules are purchased separately.
Plan the Power System
Dual 48–55 V DC terminal-block inputs allow two suitable external power sources to be connected for redundancy. A power supply is not included. Size the supply for the switch and the intended PoE load, allowing appropriate headroom and temperature derating. Installation and protective grounding should follow the manufacturer instructions.
Power Devices Over the Network
IEEE 802.3af/at support provides up to 30W per powered port within the shared 120W budget. Add the actual endpoint requirements rather than multiplying the maximum port rating by every port. Sufficient DC input power and suitable cabling are required; available power at the device also depends on the Ethernet standard and cable losses.
Connect Without Configuration
Unmanaged operation lets a straightforward network extension start without switch configuration. Auto MDI/MDIX and auto-negotiation simplify compatible copper connections. Keep the topology free of accidental loops and provide network segmentation upstream when needed; this model does not replace the policy controls of a managed switch.
A Practical Industrial Installation
A compact DIN-rail installation suits organised equipment cabinets. Visible power and port indicators help with on-site checks, while Energy-Efficient Ethernet reduces consumption when compatible links are lightly used. Keep access to the terminals and fibre connections clear, and select cables and transceivers rated for the actual site conditions.
Summary
The DIS-100G-06P is a compact industrial unmanaged switch for dependable Gigabit access with PoE+ power. Specify the DC supply, optics and protective installation alongside the switch so the complete network is ready for its environment.
Frequently Asked Questions
Is a Power Supply Included?
No. This offer requires a separate suitable 48–55 V DC DC power supply. The source must cover the intended PoE load as well as the switch, with appropriate installation headroom.
Does This Switch Power Cameras or Access Points?
Yes, compatible IEEE 802.3af/at devices can use the 4 powered copper ports, with up to 30W per port and a 120W shared budget.
Can It Be Installed Outdoors?
Use it inside a suitable protective cabinet. The IP40 enclosure is not weatherproof. The installation must meet the specified temperature and humidity conditions and include appropriate grounding.
Are the Fibre Modules Included?
No. The two Gigabit SFP slots accept separately selected compatible transceivers. Match fibre type, wavelength, distance and environmental rating at both ends.
Can I Configure VLANs and Redundant Links?
This is an unmanaged switch without a configuration interface. Use suitable managed equipment upstream for VLAN policy and avoid accidental cable loops.
What Does Dual Power Input Mean?
Two suitable 48–55 V DC supplies can be wired to the terminal inputs so one source can sustain operation if the other fails. The supplies are purchased separately and must be correctly rated for the complete load.
Specs
D-Link DIS-100G-06P 6-Port Gigabit Industrial Unmanaged PoE+ Switch
The DIS-100G-06P is a 6-port industrial unmanaged Gigabit Ethernet switch with 4 copper ports and two Gigabit SFP slots. It supplies IEEE 802.3af/at PoE+ within a shared power budget. The fanless IP40 metal enclosure supports DIN-rail installation and dual DC terminal inputs. A suitably rated DC power supply and any fibre transceivers are required separately. Use a protective enclosure wherever the installation is exposed to water, dust or other site hazards.
| Specification | Details |
|---|---|
| Interfaces and Performance | |
| Copper Ethernet | 4 × 10/100/1000BASE-T with IEEE 802.3af/at PoE+ |
| Fibre Uplinks | 2 × Gigabit SFP slots; transceivers sold separately |
| Switching Capacity | 12 Gbps |
| 64-Byte Packet Forwarding | 8.92 Mpps |
| MAC Address Table | 8K entries |
| Forwarding Method | Store-and-forward |
| Jumbo Frames | Up to 9 KB |
| Copper Link Functions | Auto-negotiation and auto MDI/MDIX |
| Power and Installation | |
| Power Input | Dual 48–55 V DC terminal-block inputs |
| DC Power Supply | Required separately; size for the complete load and installation conditions |
| PoE Capability | 4 IEEE 802.3af/at ports; up to 30W per port; 120W shared budget |
| Maximum Consumption | 123.2W with PoE; 6.3W without PoE |
| Standby Consumption | Up to 2.49W |
| Mounting | DIN rail |
| Cooling | Fanless passive cooling |
| Surge Protection | 6kV on copper Ethernet ports; correct grounding required |
| Network Functions | |
| Administration | Unmanaged plug-and-play |
| Traffic Control | IEEE 802.3x flow control |
| Resilience | Dual DC input for a planned redundant-power arrangement |
| Routing and Security | Configuration and network policy provided by upstream equipment |
| Diagnostics | Power and link/activity indicators |
| Physical and Environmental | |
| Enclosure | IP40-rated metal casing |
| Dimensions (L × W × H) | 138 × 108 × 44 mm |
| Device Weight | 0.63 kg |
| Operating Temperature | −40°C to 75°C |
| Storage Temperature | −40°C to 85°C |
| Humidity | Operating and storage 5–95% RH |
| Safety and Emissions | cUL, CB, CE, BSMI; FCC Class A, VCCI Class A, IC and RCM |
| Warranty | 5 years |
| Supplied and Required Items | |
| Switch and Mounting | Switch, DIN-rail mounting kit and DC terminal block |
| Required Separately | Suitable DC power supply; Ethernet/fibre cables and compatible transceivers as required |