D-Link DGS-F1010P-E 10-Port Gigabit PoE+ Switch
A Compact Power Source for Connected Devices The DGS-F1010P-E combines 8 Gigabit PoE+ ports with two Gigabit copper uplinks for cameras, wireless access points and IP phones. Its 96W shared PoE budget provides a practical power base for a planned installation. Unmanaged plug-and-play operation keeps a small network extension straightforward. The eight powered ports support extended-distance PoE operation up to 250 m where suitable for the endpoint and cabling. Extended mode reduces data rate; it is not Gigabit Ethernet over 250 m. Highlights Ports and Power 8 × 10/100/1000Mbps PoE+ ports. 2 × Gigabit RJ45 data uplinks. 96W shared PoE budget; up to 30W per port. Useful Installation Tools Long Reach PoE on eight ports, up to 250 m in reduced-speed mode. Port isolation, priority settings and PoE recovery functions. 6kV surge protection; appropriate grounding and protection remain required. Operation Unmanaged plug-and-play design without a configuration interface. Compact fanless desktop switch with external power adapter. 3-year warranty. Key Features Supply Data and Power Together IEEE 802.3af/at PoE+ can power compatible endpoints through the same cable used for network data. Up to 30W per port is available within a 96W shared budget. Add the actual endpoint demands and allow headroom rather than multiplying the maximum rating by every port. Keep Uplinks Separate Two Gigabit RJ45 uplinks connect the switch to a router, recorder or another switch without consuming the eight powered access ports. The uplinks do not provide PoE output and are copper connections rather than fibre SFP slots. Reach Appropriate Distant Endpoints Long Reach mode supports selected suitable PoE installations up to 250 m with appropriate cabling. The mode reduces the port data rate, so check the camera or endpoint bandwidth and power needs before using it. Normal Gigabit links follow standard Ethernet channel limits. Make Fault Recovery Easier The PoE recovery function monitors a powered device and can restart power to a device that stops responding. It is an installation aid, not a guarantee against every endpoint fault. Test the chosen setting with the connected cameras or access points before relying on automatic restarts. Apply the Right Network Controls Physical shortcuts provide functions such as port isolation and video priority without a managed-switch interface. This suits a straightforward camera or endpoint extension. Where the design requires detailed VLAN configuration, authentication or routing, choose appropriately managed equipment. Install for the Real Environment A compact fanless enclosure suits desks, cabinets and quieter rooms. The supplied external adapter powers the switch and shared PoE load. This is indoor equipment; surge protection does not make it waterproof or replace safe grounding and site lightning protection. Summary The DGS-F1010P-E brings Gigabit endpoint connections and a 96W shared PoE+ budget to compact plug-and-play networks. Plan endpoint power, uplinks and extended-distance settings together for a practical surveillance or business network. Frequently Asked Questions How Many Devices Can Receive PoE?ExpandCollapse 8 copper access ports support IEEE 802.3af/at PoE+, up to 30W per port within the 96W total budget. The two uplinks are separate from these powered access ports. Does 250 m Mode Keep Gigabit Speed?ExpandCollapse No. Extended-distance mode reduces the data rate. Confirm that the endpoint bandwidth, cable and power needs suit this mode before installation. Are the Uplinks Fibre or Copper?ExpandCollapse Both uplinks are Gigabit RJ45 copper ports. This model does not have SFP fibre slots. Can I Configure VLANs?ExpandCollapse This is an unmanaged model. Physical port-isolation shortcuts are available, but it does not provide the detailed configuration interface of a managed VLAN switch. Is the Power Supply Included?ExpandCollapse Yes. The normal offer uses the external power adapter specified for the 96W model. Can It Be Installed Outdoors?ExpandCollapse The switch is intended for a suitable protected indoor installation. Its surge protection does not establish a waterproof outdoor rating. Keep within the specified environmental limits and provide appropriate grounding.
Add-ons (1)
Pickup available at 3005, Ubi Avenue 3, #01-88
Usually ready in 2-4 Business Day (Excluding Public Holiday)
D-Link DGS-F1010P-E 10-Port Gigabit PoE+ Switch
Description
A Compact Power Source for Connected Devices
The DGS-F1010P-E combines 8 Gigabit PoE+ ports with two Gigabit copper uplinks for cameras, wireless access points and IP phones. Its 96W shared PoE budget provides a practical power base for a planned installation.
Unmanaged plug-and-play operation keeps a small network extension straightforward. The eight powered ports support extended-distance PoE operation up to 250 m where suitable for the endpoint and cabling. Extended mode reduces data rate; it is not Gigabit Ethernet over 250 m.
Highlights
Ports and Power
- 8 × 10/100/1000Mbps PoE+ ports.
- 2 × Gigabit RJ45 data uplinks.
- 96W shared PoE budget; up to 30W per port.
Useful Installation Tools
- Long Reach PoE on eight ports, up to 250 m in reduced-speed mode.
- Port isolation, priority settings and PoE recovery functions.
- 6kV surge protection; appropriate grounding and protection remain required.
Operation
- Unmanaged plug-and-play design without a configuration interface.
- Compact fanless desktop switch with external power adapter.
- 3-year warranty.
Key Features
Supply Data and Power Together
IEEE 802.3af/at PoE+ can power compatible endpoints through the same cable used for network data. Up to 30W per port is available within a 96W shared budget. Add the actual endpoint demands and allow headroom rather than multiplying the maximum rating by every port.
Keep Uplinks Separate
Two Gigabit RJ45 uplinks connect the switch to a router, recorder or another switch without consuming the eight powered access ports. The uplinks do not provide PoE output and are copper connections rather than fibre SFP slots.
Reach Appropriate Distant Endpoints
Long Reach mode supports selected suitable PoE installations up to 250 m with appropriate cabling. The mode reduces the port data rate, so check the camera or endpoint bandwidth and power needs before using it. Normal Gigabit links follow standard Ethernet channel limits.
Make Fault Recovery Easier
The PoE recovery function monitors a powered device and can restart power to a device that stops responding. It is an installation aid, not a guarantee against every endpoint fault. Test the chosen setting with the connected cameras or access points before relying on automatic restarts.
Apply the Right Network Controls
Physical shortcuts provide functions such as port isolation and video priority without a managed-switch interface. This suits a straightforward camera or endpoint extension. Where the design requires detailed VLAN configuration, authentication or routing, choose appropriately managed equipment.
Install for the Real Environment
A compact fanless enclosure suits desks, cabinets and quieter rooms. The supplied external adapter powers the switch and shared PoE load. This is indoor equipment; surge protection does not make it waterproof or replace safe grounding and site lightning protection.
Summary
The DGS-F1010P-E brings Gigabit endpoint connections and a 96W shared PoE+ budget to compact plug-and-play networks. Plan endpoint power, uplinks and extended-distance settings together for a practical surveillance or business network.
Frequently Asked Questions
How Many Devices Can Receive PoE?
8 copper access ports support IEEE 802.3af/at PoE+, up to 30W per port within the 96W total budget. The two uplinks are separate from these powered access ports.
Does 250 m Mode Keep Gigabit Speed?
No. Extended-distance mode reduces the data rate. Confirm that the endpoint bandwidth, cable and power needs suit this mode before installation.
Are the Uplinks Fibre or Copper?
Both uplinks are Gigabit RJ45 copper ports. This model does not have SFP fibre slots.
Can I Configure VLANs?
This is an unmanaged model. Physical port-isolation shortcuts are available, but it does not provide the detailed configuration interface of a managed VLAN switch.
Is the Power Supply Included?
Yes. The normal offer uses the external power adapter specified for the 96W model.
Can It Be Installed Outdoors?
The switch is intended for a suitable protected indoor installation. Its surge protection does not establish a waterproof outdoor rating. Keep within the specified environmental limits and provide appropriate grounding.
Specs
D-Link DGS-F1010P-E 10-Port Gigabit PoE+ Switch
The DGS-F1010P-E is a compact unmanaged desktop Gigabit PoE+ switch with 8 powered RJ45 access ports and two Gigabit copper uplinks. IEEE 802.3af/at supports up to 30W per port within a 96W shared budget. Eight powered ports support extended-distance operation up to 250 m using a reduced data rate and suitable cabling. The fanless design uses an external power adapter and physical function shortcuts.
| Specification | Details |
|---|---|
| Interfaces and Performance | |
| PoE Access | 8 × 10/100/1000BASE-T RJ45 |
| Uplinks | 2 × 10/100/1000BASE-T RJ45 |
| Switching Capacity | 20 Gbps |
| Forwarding | Store-and-forward; up to 1,488,000 pps per Gigabit port |
| Console | No managed console |
| PoE and Network Functions | |
| PoE Standards | IEEE 802.3af/at; up to 30W per port |
| Shared Power Budget | 96W |
| Long Reach Mode | 8 ports; up to 250 m at reduced data rate with suitable cabling |
| Shortcut Functions | Port isolation, Extend, PoE Watchguard and priority / QoS |
| Management | Unmanaged plug-and-play |
| Traffic and Security | Physical isolation and video-priority functions |
| Surge Protection | 6kV; appropriate grounding and protective installation required |
| Power and Installation | |
| Supply | External 96W power adapter |
| Maximum Consumption | Powered by the specified 96W adapter |
| Cooling and Acoustics | Fanless passive cooling |
| Mounting | Desktop |
| Physical and Environmental | |
| Dimensions (W × D × H) | 184 × 75 × 27 mm |
| Device Weight | 0.95 kg |
| Operating Temperature | 0°C to 40°C |
| Humidity | Operating and storage 0–95% RH non-condensing |
| Warranty | 3 years |
| Supplied and Required Items | |
| Normal Offer | Switch and specified external power adapter |
| Required Separately | Suitable Ethernet connection cables |