Ablerex ABX RT Rack/Tower Online UPS
Online power protection with a clear real-power budget The Ablerex ABX RT is an online double-conversion UPS with a 1.0 output power factor. Its VA and watt ratings are matched, making it straightforward to plan a protected IT load while still leaving headroom for normal operating conditions and growth. Pure sine-wave output, local management interfaces and an optional communication-card slot provide the foundations for a managed power-protection installation. Select the exact capacity and configuration against the electrical supply, battery runtime and equipment space required by your NAS, server or network. Highlights Online protection Double-conversion topology and pure sine-wave output 1.0 output power factor A defined installation Rack/tower configuration Match capacity, input/output connections and mounting space Monitoring and response USB and RS232 communication Optional compatible SNMP or dry-contact card Key Features Online double conversion The inverter supplies a controlled AC output in normal online operation, isolating the protected load from many incoming mains variations. Choose the operating mode deliberately: economy and bypass operation have different power paths from the normal double-conversion mode. A defined load budget Match both the VA and watt limits to the connected equipment, leaving appropriate headroom. Include the NAS, switch and essential network devices you need during shutdown, and check the runtime at that combined load. Monitoring that fits the installation USB and RS232 allow supported local monitoring. An optional, compatible network-management card can add network visibility. Automated host shutdown requires the correct software or NAS integration and a tested end-to-end configuration. Battery care over the service life Battery performance changes with temperature, age and use. Provide ventilation, test the shutdown procedure and arrange appropriate battery inspection or replacement rather than treating the UPS as an install-and-forget device. Plan the exact physical configuration Capacity and hardware revision can change the enclosure height, depth and connection arrangement. Confirm the selected configuration and mounting requirements before installation; a family photograph does not establish a common chassis size across every option. Compatible Models Matched NAS, server and networking loads within the selected VA/watt limits and supplied electrical connection requirements. The ABX-specific RC67501 communication option is separate from the ARES Plus/MSII CY504B card. Confirm exact interface and shutdown support before installation. Summary ABX RT provides pure sine-wave online power protection and a 1.0 output power factor for a correctly specified IT installation. Match the physical configuration, connected load, monitoring requirements and shutdown window before deployment. Frequently asked questions What is the output power factor?ExpandCollapse The ABX range has a 1.0 output power factor, so its VA and watt ratings match. Keep the connected load within the selected limits and leave appropriate headroom. Does it provide pure sine-wave output?ExpandCollapse Yes. The ABX online double-conversion design provides pure sine-wave output. How much backup time will I get?ExpandCollapse Runtime depends on the actual connected load, battery condition, temperature and the selected battery configuration. Size the UPS for both its VA and watt limits, then check the runtime required for shutdown or short power interruptions. Can it shut down a NAS or server automatically?ExpandCollapse Automatic shutdown requires a supported communication interface and compatible software or NAS integration. Check the exact host support and test the complete shutdown and restart sequence during commissioning. Which network-management card should I choose?ExpandCollapse Use the ABX-specific compatible card, identified in the range as RC67501. Do not assume that the CY504B card used by other Ablerex UPS families is interchangeable. Are installation and additional accessories included?ExpandCollapse This is a UPS hardware listing. Any optional network card, external battery cabinet, rack rails, electrical work or commissioning must be selected or agreed separately.
Pickup available at 3005, Ubi Avenue 3, #01-88
Usually ready in 2-4 Business Day (Excluding Public Holiday)
Ablerex ABX RT Rack/Tower Online UPS
Description
Online power protection with a clear real-power budget
The Ablerex ABX RT is an online double-conversion UPS with a 1.0 output power factor. Its VA and watt ratings are matched, making it straightforward to plan a protected IT load while still leaving headroom for normal operating conditions and growth.
Pure sine-wave output, local management interfaces and an optional communication-card slot provide the foundations for a managed power-protection installation. Select the exact capacity and configuration against the electrical supply, battery runtime and equipment space required by your NAS, server or network.
Highlights
Online protection
- Double-conversion topology and pure sine-wave output
- 1.0 output power factor
A defined installation
- Rack/tower configuration
- Match capacity, input/output connections and mounting space
Monitoring and response
- USB and RS232 communication
- Optional compatible SNMP or dry-contact card
Key Features
Online double conversion
The inverter supplies a controlled AC output in normal online operation, isolating the protected load from many incoming mains variations. Choose the operating mode deliberately: economy and bypass operation have different power paths from the normal double-conversion mode.
A defined load budget
Match both the VA and watt limits to the connected equipment, leaving appropriate headroom. Include the NAS, switch and essential network devices you need during shutdown, and check the runtime at that combined load.
Monitoring that fits the installation
USB and RS232 allow supported local monitoring. An optional, compatible network-management card can add network visibility. Automated host shutdown requires the correct software or NAS integration and a tested end-to-end configuration.
Battery care over the service life
Battery performance changes with temperature, age and use. Provide ventilation, test the shutdown procedure and arrange appropriate battery inspection or replacement rather than treating the UPS as an install-and-forget device.
Plan the exact physical configuration
Capacity and hardware revision can change the enclosure height, depth and connection arrangement. Confirm the selected configuration and mounting requirements before installation; a family photograph does not establish a common chassis size across every option.
Compatible Models
Matched NAS, server and networking loads within the selected VA/watt limits and supplied electrical connection requirements. The ABX-specific RC67501 communication option is separate from the ARES Plus/MSII CY504B card. Confirm exact interface and shutdown support before installation.
Summary
ABX RT provides pure sine-wave online power protection and a 1.0 output power factor for a correctly specified IT installation. Match the physical configuration, connected load, monitoring requirements and shutdown window before deployment.
Frequently asked questions
What is the output power factor?
The ABX range has a 1.0 output power factor, so its VA and watt ratings match. Keep the connected load within the selected limits and leave appropriate headroom.
Does it provide pure sine-wave output?
Yes. The ABX online double-conversion design provides pure sine-wave output.
How much backup time will I get?
Runtime depends on the actual connected load, battery condition, temperature and the selected battery configuration. Size the UPS for both its VA and watt limits, then check the runtime required for shutdown or short power interruptions.
Can it shut down a NAS or server automatically?
Automatic shutdown requires a supported communication interface and compatible software or NAS integration. Check the exact host support and test the complete shutdown and restart sequence during commissioning.
Which network-management card should I choose?
Use the ABX-specific compatible card, identified in the range as RC67501. Do not assume that the CY504B card used by other Ablerex UPS families is interchangeable.
Are installation and additional accessories included?
This is a UPS hardware listing. Any optional network card, external battery cabinet, rack rails, electrical work or commissioning must be selected or agreed separately.
Specs
Ablerex ABX RT Rack/Tower Online UPS
Online double-conversion UPS hardware with a 1.0 output power factor for matched IT loads. Use the exact selected capacity, electrical connections and battery configuration when planning the installation. Physical enclosure dimensions can change with capacity and revision. Runtime depends on actual load and battery condition, and software-assisted shutdown requires a supported and tested communication setup.
| Specification | Details |
|---|---|
| UPS and Capacity | |
| Topology | Online double conversion |
| Rated capacity | 1000 VA / 1000 W; 3000 VA / 3000 W |
| Output power factor | 1.0 |
| Output waveform | Pure sine wave |
| Power and Operation | |
| Nominal input/output | 220/ 230/ 240 V AC; single phase with earth |
| Cold start | Supported |
| Runtime | Depends on actual load, battery condition and installed battery configuration |
| Monitoring and Interfaces | |
| Local communication | USB and RS232 |
| Display | Graphical LCD on the RT family |
| Option slot | Compatible SNMP or dry-contact card; sold separately |
| Shutdown integration | Requires supported host software and commissioning |
| Battery and Installation | |
| Standard battery chemistry | Sealed maintenance-free lead-acid |
| Battery configuration | Selected standard capacity and hardware revision must be matched |
| Physical format | Rack/tower |
| Mounting envelope | Confirm height, depth and mounting hardware for selected capacity/revision |
| Operating temperature | 0–40°C |
| Scope | UPS hardware; optional accessories, electrical work and commissioning separate |