D-Link DXS-FAN100 Front-to-Back Fan Module
Keep Compatible Switch Cooling Serviceable The DXS-FAN100 is a hot-swappable cooling module with front-to-back airflow for supported D-Link switches. It gives a compatible installation a defined service component rather than relying on a generic replacement. Confirm the exact host and airflow before selecting a spare. The DXS-3400-24TC and DXS-3400-24SC support this module. It replaces one compatible fan module; it does not turn a different fan tray or airflow variant into a supported configuration. Keep the switch ventilation path clear and follow the host service procedure. Highlights Designed for the Host Compatible with DXS-3400-24TC and DXS-3400-24SC. Front-to-back airflow. Exact host, module and airflow must match. Service Component Hot-swappable fan module. Hot-swappable in a supported host. One service module supplied; switch sold separately. Practical Planning Retain the host’s complete required fan population. Install according to the host hardware guide. 1-year warranty. Key Features Choose the Correct Service Module Check the switch model, hardware revision and the existing module label before ordering. The compatible DXS-3400 models use a defined modular design. Physical similarity or a shared D-Link brand does not make a different PSU or fan compatible. Keep the Airflow Consistent This is the front-to-back airflow version. The rest of the switch cooling system and the rack ventilation must follow the intended direction. Mixing airflow designs can compromise cooling even when a module appears to fit. Replace Without an Unnecessary Rebuild The hot-swappable design supports servicing a compatible powered host under the manufacturer’s instructions. The switch must retain the power and cooling needed during the operation. Use the correct procedure rather than treating hot-swap as permission to remove multiple essential modules together. Understand the Module’s Role The module supports the switch’s designed cooling path. It is not a general-purpose desk fan or an upgrade that increases port speed. Keep all required fan slots populated and maintain the ambient conditions specified for the host. Plan Access in the Rack Leave enough service clearance to release and withdraw the module safely. Keep cables from obstructing the extraction path, and confirm that the replacement is fully seated. Label a spare clearly so the correct module is available during maintenance. Commission After Replacement Check the host’s status indicators and management alarms after installation. Confirm that the new module is recognised and that power or fan alerts have cleared. Keep the service record and failed component separate for troubleshooting. Summary The DXS-FAN100 is a purpose-matched fan module for supported front-to-back-airflow D-Link switches. Confirm the host and module identity, maintain the required redundant components and verify the switch after service. Frequently Asked Questions Which Switches Are Explicitly Supported?ExpandCollapse The DXS-3400-24TC and DXS-3400-24SC are explicitly listed. Do not infer compatibility with other DXS switches from a similar module shape. Is This a Complete Switch?ExpandCollapse No. This offer supplies one fan module. The compatible switch is purchased separately. Does It Have Front-to-Back Airflow?ExpandCollapse Yes. Match it to the host’s required airflow direction and the rack cooling arrangement. It is not the back-to-front version. Can It Be Hot-Swapped?ExpandCollapse Yes, in a compatible host and under the hardware guide’s service procedure. Maintain the remaining power and cooling requirements while replacing the module. Does It Fit DXS-3610 Switches?ExpandCollapse No compatibility is specified here for DXS-3610. That series uses different PSU and fan families. Check the exact supported service part instead of substituting this module. How Many Fan Modules Are Included?ExpandCollapse This offer includes one fan module. The switch must retain its full required cooling configuration. Check the host hardware guide before deciding how many replacement modules to order or remove.
可在 3005, Ubi Avenue 3, #01-88 提货
通常在 2 至 4 个工作日内备妥(公共假期除外)
D-Link DXS-FAN100 Front-to-Back Fan Module
描述
Keep Compatible Switch Cooling Serviceable
The DXS-FAN100 is a hot-swappable cooling module with front-to-back airflow for supported D-Link switches. It gives a compatible installation a defined service component rather than relying on a generic replacement. Confirm the exact host and airflow before selecting a spare.
The DXS-3400-24TC and DXS-3400-24SC support this module. It replaces one compatible fan module; it does not turn a different fan tray or airflow variant into a supported configuration. Keep the switch ventilation path clear and follow the host service procedure.
Highlights
Designed for the Host
- Compatible with DXS-3400-24TC and DXS-3400-24SC.
- Front-to-back airflow.
- Exact host, module and airflow must match.
Service Component
- Hot-swappable fan module.
- Hot-swappable in a supported host.
- One service module supplied; switch sold separately.
Practical Planning
- Retain the host’s complete required fan population.
- Install according to the host hardware guide.
- 1-year warranty.
Key Features
Choose the Correct Service Module
Check the switch model, hardware revision and the existing module label before ordering. The compatible DXS-3400 models use a defined modular design. Physical similarity or a shared D-Link brand does not make a different PSU or fan compatible.
Keep the Airflow Consistent
This is the front-to-back airflow version. The rest of the switch cooling system and the rack ventilation must follow the intended direction. Mixing airflow designs can compromise cooling even when a module appears to fit.
Replace Without an Unnecessary Rebuild
The hot-swappable design supports servicing a compatible powered host under the manufacturer’s instructions. The switch must retain the power and cooling needed during the operation. Use the correct procedure rather than treating hot-swap as permission to remove multiple essential modules together.
Understand the Module’s Role
The module supports the switch’s designed cooling path. It is not a general-purpose desk fan or an upgrade that increases port speed. Keep all required fan slots populated and maintain the ambient conditions specified for the host.
Plan Access in the Rack
Leave enough service clearance to release and withdraw the module safely. Keep cables from obstructing the extraction path, and confirm that the replacement is fully seated. Label a spare clearly so the correct module is available during maintenance.
Commission After Replacement
Check the host’s status indicators and management alarms after installation. Confirm that the new module is recognised and that power or fan alerts have cleared. Keep the service record and failed component separate for troubleshooting.
Summary
The DXS-FAN100 is a purpose-matched fan module for supported front-to-back-airflow D-Link switches. Confirm the host and module identity, maintain the required redundant components and verify the switch after service.
Frequently Asked Questions
Which Switches Are Explicitly Supported?
The DXS-3400-24TC and DXS-3400-24SC are explicitly listed. Do not infer compatibility with other DXS switches from a similar module shape.
Is This a Complete Switch?
No. This offer supplies one fan module. The compatible switch is purchased separately.
Does It Have Front-to-Back Airflow?
Yes. Match it to the host’s required airflow direction and the rack cooling arrangement. It is not the back-to-front version.
Can It Be Hot-Swapped?
Yes, in a compatible host and under the hardware guide’s service procedure. Maintain the remaining power and cooling requirements while replacing the module.
Does It Fit DXS-3610 Switches?
No compatibility is specified here for DXS-3610. That series uses different PSU and fan families. Check the exact supported service part instead of substituting this module.
How Many Fan Modules Are Included?
This offer includes one fan module. The switch must retain its full required cooling configuration. Check the host hardware guide before deciding how many replacement modules to order or remove.
规格
D-Link DXS-FAN100 Front-to-Back Fan Module
The DXS-FAN100 is a modular cooling fan for compatible D-Link switches using front-to-back airflow. The manufacturer explicitly lists the DXS-3400-24TC and DXS-3400-24SC. It is hot-swappable when the host service instructions and remaining power or cooling requirements are followed. One module is supplied; the switch is separate. Check the exact host, existing module and airflow direction before installation. Compatibility is not inferred for DXS-3610 or unrelated DXS models.
| Specification | Details |
|---|---|
| Function and Compatibility | |
| Component | Modular cooling fan |
| Verified Hosts | DXS-3400-24TC and DXS-3400-24SC |
| Airflow | Front to back |
| Serviceability | Hot-swappable in supported host; follow host hardware guide |
| Included | One module; switch sold separately |
| Physical and Service | |
| Dimensions | 139.2 × 57.9 × 40.6 mm |
| Installation | Use the matching service slot and preserve required power/cooling population |