Managed Control Where the Network Meets the Worksite The DIS-210G-06P connects equipment in industrial cabinets, production areas and protected surveillance installations. 4 Gigabit Ethernet ports and two Gigabit SFP slots provide a practical mix of local copper connections and separately specified fibre links. Its fanless metal enclosure mounts on a DIN rail and supports operation from −40°C to 75°C. Four PoE+ ports supply up to 30W each within a 120W shared budget. VLANs, ERPS, access controls and static routing add configuration and diagnostic tools for a planned industrial network. Highlights Industrial Connectivity 4 × 10/100/1000BASE-T PoE+ and 2 × Gigabit SFP slots. 12 Gbps switching capacity and up to 8.92 Mpps forwarding. Fanless DIN-rail design for industrial cabinets. Power and Installation Dual 48–55 V DC terminal-block inputs; suitable DC power supply required separately. Up to 120W shared PoE+ power and 30W per powered port. IP40 metal housing and −40°C to 75°C operating range. Network Operation Managed VLAN, ERPS, security and static-routing functions. 6kV surge protection on copper Ethernet ports. 5-year warranty. Key Features Built for Equipment Cabinets A fanless enclosure avoids a cooling fan as an additional maintenance point. The specified −40°C to 75°C operating range supports installations beyond a temperature-controlled office. The IP40 rating is not a weatherproof outdoor rating: install the switch inside a suitable enclosure with the required grounding, ventilation and protection from water. Copper Access With Fibre Reach 4 Gigabit copper ports connect local equipment while two SFP slots provide fibre connection choices. Select compatible transceivers, fibre type, wavelength and distance for both ends of the link. The slots operate at Gigabit speed; they are not 10GbE uplinks, and optical modules are purchased separately. Plan the Power System Dual 48–55 V DC terminal-block inputs allow two suitable external power sources to be connected for redundancy. A power supply is not included. Size the supply for the switch and the intended PoE load, allowing appropriate headroom and temperature derating. Installation and protective grounding should follow the manufacturer instructions. Power Devices Over the Network IEEE 802.3af/at support provides up to 30W per powered port within the shared 120W budget. Add the actual endpoint requirements rather than multiplying the maximum port rating by every port. Sufficient DC input power and suitable cabling are required; available power at the device also depends on the Ethernet standard and cable losses. Control Traffic at the Edge 802.1Q VLANs separate services, while link aggregation, spanning-tree protocols and ERPS support a deliberately designed topology. Static routing connects selected networks locally. Configure and test redundancy before relying on it; multiple cables alone do not establish a resilient network or remove the need for an upstream firewall. Clearer Fault Finding A browser interface and CLI provide configuration access. Cable diagnostics, logs and Ethernet OAM help a network administrator investigate connection problems, while supported access controls restrict use according to the site policy. Keep management credentials secure and plan maintenance access before the switch is installed in a cabinet. Summary The DIS-210G-06P is a compact industrial managed switch for dependable Gigabit access with PoE+ power. Specify the DC supply, optics and protective installation alongside the switch so the complete network is ready for its environment. Frequently Asked Questions Is a Power Supply Included?ExpandCollapse No. This offer requires a separate suitable 48–55 V DC DC power supply. The source must cover the intended PoE load as well as the switch, with appropriate installation headroom. Does This Switch Power Cameras or Access Points?ExpandCollapse Yes, compatible IEEE 802.3af/at devices can use the 4 powered copper ports, with up to 30W per port and a 120W shared budget. Can It Be Installed Outdoors?ExpandCollapse Use it inside a suitable protective cabinet. The IP40 enclosure is not weatherproof. The installation must meet the specified temperature and humidity conditions and include appropriate grounding. Are the Fibre Modules Included?ExpandCollapse No. The two Gigabit SFP slots accept separately selected compatible transceivers. Match fibre type, wavelength, distance and environmental rating at both ends. Can I Configure VLANs and Redundant Links?ExpandCollapse Yes. This managed model supports VLANs, spanning tree, ERPS and static routing. Plan and test the network configuration before deployment. What Does Dual Power Input Mean?ExpandCollapse Two suitable 48–55 V DC supplies can be wired to the terminal inputs so one source can sustain operation if the other fails. The supplies are purchased separately and must be correctly rated for the complete load.
附加组件 (1)
可在 3005, Ubi Avenue 3, #01-88 提货
通常在 2 至 4 个工作日内备妥(公共假期除外)
D-Link DIS-210G-06P 6-Port Gigabit Industrial Managed PoE+ Switch
描述
Managed Control Where the Network Meets the Worksite
The DIS-210G-06P connects equipment in industrial cabinets, production areas and protected surveillance installations. 4 Gigabit Ethernet ports and two Gigabit SFP slots provide a practical mix of local copper connections and separately specified fibre links. Its fanless metal enclosure mounts on a DIN rail and supports operation from −40°C to 75°C.
Four PoE+ ports supply up to 30W each within a 120W shared budget. VLANs, ERPS, access controls and static routing add configuration and diagnostic tools for a planned industrial network.
Highlights
Industrial Connectivity
- 4 × 10/100/1000BASE-T PoE+ and 2 × Gigabit SFP slots.
- 12 Gbps switching capacity and up to 8.92 Mpps forwarding.
- Fanless DIN-rail design for industrial cabinets.
Power and Installation
- Dual 48–55 V DC terminal-block inputs; suitable DC power supply required separately.
- Up to 120W shared PoE+ power and 30W per powered port.
- IP40 metal housing and −40°C to 75°C operating range.
Network Operation
- Managed VLAN, ERPS, security and static-routing functions.
- 6kV surge protection on copper Ethernet ports.
- 5-year warranty.
Key Features
Built for Equipment Cabinets
A fanless enclosure avoids a cooling fan as an additional maintenance point. The specified −40°C to 75°C operating range supports installations beyond a temperature-controlled office. The IP40 rating is not a weatherproof outdoor rating: install the switch inside a suitable enclosure with the required grounding, ventilation and protection from water.
Copper Access With Fibre Reach
4 Gigabit copper ports connect local equipment while two SFP slots provide fibre connection choices. Select compatible transceivers, fibre type, wavelength and distance for both ends of the link. The slots operate at Gigabit speed; they are not 10GbE uplinks, and optical modules are purchased separately.
Plan the Power System
Dual 48–55 V DC terminal-block inputs allow two suitable external power sources to be connected for redundancy. A power supply is not included. Size the supply for the switch and the intended PoE load, allowing appropriate headroom and temperature derating. Installation and protective grounding should follow the manufacturer instructions.
Power Devices Over the Network
IEEE 802.3af/at support provides up to 30W per powered port within the shared 120W budget. Add the actual endpoint requirements rather than multiplying the maximum port rating by every port. Sufficient DC input power and suitable cabling are required; available power at the device also depends on the Ethernet standard and cable losses.
Control Traffic at the Edge
802.1Q VLANs separate services, while link aggregation, spanning-tree protocols and ERPS support a deliberately designed topology. Static routing connects selected networks locally. Configure and test redundancy before relying on it; multiple cables alone do not establish a resilient network or remove the need for an upstream firewall.
Clearer Fault Finding
A browser interface and CLI provide configuration access. Cable diagnostics, logs and Ethernet OAM help a network administrator investigate connection problems, while supported access controls restrict use according to the site policy. Keep management credentials secure and plan maintenance access before the switch is installed in a cabinet.
Summary
The DIS-210G-06P is a compact industrial managed switch for dependable Gigabit access with PoE+ power. Specify the DC supply, optics and protective installation alongside the switch so the complete network is ready for its environment.
Frequently Asked Questions
Is a Power Supply Included?
No. This offer requires a separate suitable 48–55 V DC DC power supply. The source must cover the intended PoE load as well as the switch, with appropriate installation headroom.
Does This Switch Power Cameras or Access Points?
Yes, compatible IEEE 802.3af/at devices can use the 4 powered copper ports, with up to 30W per port and a 120W shared budget.
Can It Be Installed Outdoors?
Use it inside a suitable protective cabinet. The IP40 enclosure is not weatherproof. The installation must meet the specified temperature and humidity conditions and include appropriate grounding.
Are the Fibre Modules Included?
No. The two Gigabit SFP slots accept separately selected compatible transceivers. Match fibre type, wavelength, distance and environmental rating at both ends.
Can I Configure VLANs and Redundant Links?
Yes. This managed model supports VLANs, spanning tree, ERPS and static routing. Plan and test the network configuration before deployment.
What Does Dual Power Input Mean?
Two suitable 48–55 V DC supplies can be wired to the terminal inputs so one source can sustain operation if the other fails. The supplies are purchased separately and must be correctly rated for the complete load.
规格
D-Link DIS-210G-06P 6-Port Gigabit Industrial Managed PoE+ Switch
The DIS-210G-06P is a 6-port industrial managed Gigabit Ethernet switch with 4 copper ports and two Gigabit SFP slots. It supplies IEEE 802.3af/at PoE+ within a shared power budget. The fanless IP40 metal enclosure supports DIN-rail installation and dual DC terminal inputs. A suitably rated DC power supply and any fibre transceivers are required separately. Use a protective enclosure wherever the installation is exposed to water, dust or other site hazards.
| Specification | Details |
|---|---|
| Interfaces and Performance | |
| Copper Ethernet | 4 × 10/100/1000BASE-T with IEEE 802.3af/at PoE+ |
| Fibre Uplinks | 2 × Gigabit SFP slots; transceivers sold separately |
| Switching Capacity | 12 Gbps |
| 64-Byte Packet Forwarding | 8.92 Mpps |
| MAC Address Table | 8K entries |
| Forwarding Method | Store-and-forward |
| Jumbo Frames | Up to 9 KB |
| Copper Link Functions | Auto-negotiation and auto MDI/MDIX |
| Power and Installation | |
| Power Input | Dual 48–55 V DC terminal-block inputs |
| DC Power Supply | Required separately; size for the complete load and installation conditions |
| PoE Capability | 4 IEEE 802.3af/at ports; up to 30W per port; 120W shared budget |
| Maximum Consumption | 123.2W with PoE; 6.6W without PoE |
| Standby Consumption | Up to 2.49W |
| Mounting | DIN rail |
| Cooling | Fanless passive cooling |
| Surge Protection | 6kV on copper Ethernet ports; correct grounding required |
| Network Functions | |
| Administration | Web interface and CLI; RJ-45 console |
| Traffic Control | 802.1Q VLANs and QoS with eight queues per port |
| Resilience | STP/RSTP/MSTP and ERPS; link aggregation |
| Routing and Security | IP static routing; ACLs; 802.1X and RADIUS; DHCP snooping and IP-MAC-Port binding |
| Diagnostics | Cable diagnostics; 802.1ag CFM; 802.3ah OAM; Y.1731; logs |
| Physical and Environmental | |
| Enclosure | IP40-rated metal casing |
| Dimensions (L × W × H) | 138 × 108 × 44 mm |
| Device Weight | 0.63 kg |
| Operating Temperature | −40°C to 75°C |
| Storage Temperature | −40°C to 85°C |
| Humidity | Operating and storage 5–95% RH |
| Safety and Emissions | cUL, CB, CE, BSMI; FCC Class A, VCCI Class A, IC and RCM |
| Warranty | 5 years |
| Supplied and Required Items | |
| Switch and Mounting | Switch, DIN-rail mounting kit and DC terminal block |
| Required Separately | Suitable DC power supply; Ethernet/fibre cables and compatible transceivers as required |