Ablerex MSII-RT Online Rack Tower UPS
Ablerex MSII-RT Online Rack Tower UPS Ablerex MSII-RT provides online double-conversion power protection for server, storage and network installations that need a deliberately planned power and battery system. Its DSP-controlled power module regenerates the output supply, with pure sine-wave operation and a front LCD that makes the electrical and battery status easier to assess. These offers are UPS power modules without batteries. Add the correct external battery bank for battery backup, then plan the hardwired supply, load connection and rack support around the complete system. The separate battery architecture allows the power requirement and runtime requirement to be considered together rather than assuming one determines the other. Highlights Power Protection for Essential Equipment Online double conversion and pure sine-wave output 0.9 output power factor and no transfer interruption from normal online to battery operation LCD/LED status with electrical, load and battery information A Complete System Needs the Right Battery Bank RT power module sold without batteries Compatible external battery bank purchased separately Hardwired input/output with optional management and bypass accessories Key Features Separate Power Capacity from Runtime Select the UPS module against the equipment’s VA and watt demand, then choose the compatible battery arrangement for the shutdown or continuity window. BBC20J0000 is an external battery option for this range. Buying the power module alone does not create a working battery-backup system. Maintain a Controlled Supply Online double conversion conditions the output in normal operation, while the inverter provides pure sine-wave power. The supported battery connection allows a transition from normal online operation without a transfer interruption. This does not remove the need to protect the stored data with separate backups. See the Conditions That Matter The display shows input and output electrical values, load, battery voltage and operating status. Alarms help identify mains failure, low battery and system faults. Monitoring is most useful when the team has already agreed what to shut down, when to act and who is responsible. Build the Electrical Installation Properly The power module uses hardwired AC input and output. Suitable isolation, protective devices, earthing and load connections must be specified for the site. Optional bypass and socket-box accessories need to match the selected power rating and installation arrangement; they are not included by default. Plan the Rack as a Complete System The UPS and battery bank occupy separate rack spaces and add separate loads to the cabinet. Check usable depth, supporting hardware, ventilation and service access. Photographs of the family may show an external battery bank or a different chassis size; only the selected power module is included in this offer. Extend Monitoring with Verified Accessories The series supports optional management interfaces, including an appropriate SNMP/Web card for network monitoring and supported shutdown workflows. Confirm the card, UPS revision and host-software compatibility before deployment. Do not assume that different optional interface cards can operate together. Summary Ablerex MSII-RT is suited to a planned online UPS installation where power capacity, battery runtime and electrical integration must be considered together. Select the power module, add the verified battery bank and installation accessories, and confirm the load and shutdown arrangement before commissioning. Frequently Asked Questions Does the UPS Include Its Batteries?ExpandCollapse No. These MSII-RT offers are UPS power modules. A compatible external battery bank is required for battery backup and is purchased separately. The compatible BBC20J0000 module is the listed battery option for the offered range; the UPS price does not include that bank. How Do I Choose Between the Capacity Options?ExpandCollapse Compare both the VA and watt ratings with the measured load, including startup demand and sensible headroom. Then size the battery system for the required backup time. A larger UPS power module alone does not provide longer runtime without a suitable battery arrangement. Can I Plug It into an Ordinary Wall Socket?ExpandCollapse This is a hardwired UPS with hardwired input and output. Have the supply, isolation, protection, earthing and load connection assessed by a qualified electrical professional. An optional socket box or bypass assembly does not remove the need for a correctly designed installation. How Much Rack Space Does the Complete System Need?ExpandCollapse The smaller listed power module occupies 2U and the larger occupies 3U. The separate battery bank adds 3U, making 5U or 6U with one bank before service clearance, bypass hardware and other accessories. Check the rack’s usable depth and weight capacity as well as its available units. Can It Provide Network Monitoring or Server Shutdown?ExpandCollapse Network monitoring requires the correct optional SNMP/Web card and a supported shutdown configuration. CY504B supports the MSII series, but the supplied UPS revision, network settings and host software must still be checked. The card is not included in the UPS power-module price. How Long Will It Run During an Outage?ExpandCollapse That depends on the battery-bank configuration and actual connected load, as well as battery age and temperature. Share the equipment list and required runtime before selecting the bank. Keep an independent data backup and test the intended shutdown procedure after installation.
附加组件 (3)
可在 3005, Ubi Avenue 3, #01-88 提货
通常在 2 至 4 个工作日内备妥(公共假期除外)
Ablerex MSII-RT Online Rack Tower UPS
描述
Ablerex MSII-RT Online Rack Tower UPS
Ablerex MSII-RT provides online double-conversion power protection for server, storage and network installations that need a deliberately planned power and battery system. Its DSP-controlled power module regenerates the output supply, with pure sine-wave operation and a front LCD that makes the electrical and battery status easier to assess.
These offers are UPS power modules without batteries. Add the correct external battery bank for battery backup, then plan the hardwired supply, load connection and rack support around the complete system. The separate battery architecture allows the power requirement and runtime requirement to be considered together rather than assuming one determines the other.
Highlights
Power Protection for Essential Equipment
- Online double conversion and pure sine-wave output
- 0.9 output power factor and no transfer interruption from normal online to battery operation
- LCD/LED status with electrical, load and battery information
A Complete System Needs the Right Battery Bank
- RT power module sold without batteries
- Compatible external battery bank purchased separately
- Hardwired input/output with optional management and bypass accessories
Key Features
Separate Power Capacity from Runtime
Select the UPS module against the equipment’s VA and watt demand, then choose the compatible battery arrangement for the shutdown or continuity window. BBC20J0000 is an external battery option for this range. Buying the power module alone does not create a working battery-backup system.
Maintain a Controlled Supply
Online double conversion conditions the output in normal operation, while the inverter provides pure sine-wave power. The supported battery connection allows a transition from normal online operation without a transfer interruption. This does not remove the need to protect the stored data with separate backups.
See the Conditions That Matter
The display shows input and output electrical values, load, battery voltage and operating status. Alarms help identify mains failure, low battery and system faults. Monitoring is most useful when the team has already agreed what to shut down, when to act and who is responsible.
Build the Electrical Installation Properly
The power module uses hardwired AC input and output. Suitable isolation, protective devices, earthing and load connections must be specified for the site. Optional bypass and socket-box accessories need to match the selected power rating and installation arrangement; they are not included by default.
Plan the Rack as a Complete System
The UPS and battery bank occupy separate rack spaces and add separate loads to the cabinet. Check usable depth, supporting hardware, ventilation and service access. Photographs of the family may show an external battery bank or a different chassis size; only the selected power module is included in this offer.
Extend Monitoring with Verified Accessories
The series supports optional management interfaces, including an appropriate SNMP/Web card for network monitoring and supported shutdown workflows. Confirm the card, UPS revision and host-software compatibility before deployment. Do not assume that different optional interface cards can operate together.
Summary
Ablerex MSII-RT is suited to a planned online UPS installation where power capacity, battery runtime and electrical integration must be considered together. Select the power module, add the verified battery bank and installation accessories, and confirm the load and shutdown arrangement before commissioning.
Frequently Asked Questions
Does the UPS Include Its Batteries?
No. These MSII-RT offers are UPS power modules. A compatible external battery bank is required for battery backup and is purchased separately. The compatible BBC20J0000 module is the listed battery option for the offered range; the UPS price does not include that bank.
How Do I Choose Between the Capacity Options?
Compare both the VA and watt ratings with the measured load, including startup demand and sensible headroom. Then size the battery system for the required backup time. A larger UPS power module alone does not provide longer runtime without a suitable battery arrangement.
Can I Plug It into an Ordinary Wall Socket?
This is a hardwired UPS with hardwired input and output. Have the supply, isolation, protection, earthing and load connection assessed by a qualified electrical professional. An optional socket box or bypass assembly does not remove the need for a correctly designed installation.
How Much Rack Space Does the Complete System Need?
The smaller listed power module occupies 2U and the larger occupies 3U. The separate battery bank adds 3U, making 5U or 6U with one bank before service clearance, bypass hardware and other accessories. Check the rack’s usable depth and weight capacity as well as its available units.
Can It Provide Network Monitoring or Server Shutdown?
Network monitoring requires the correct optional SNMP/Web card and a supported shutdown configuration. CY504B supports the MSII series, but the supplied UPS revision, network settings and host software must still be checked. The card is not included in the UPS power-module price.
How Long Will It Run During an Outage?
That depends on the battery-bank configuration and actual connected load, as well as battery age and temperature. Share the equipment list and required runtime before selecting the bank. Keep an independent data backup and test the intended shutdown procedure after installation.
规格
Ablerex MSII-RT Online Rack Tower UPS
Specifications describe the listed single-phase RT power modules. External batteries, management cards, bypass hardware, socket boxes and installation are separate unless specifically included.
| UPS Design | |
|---|---|
| Topology | Online double conversion with DSP control |
| Installation | Rack or tower convertible power module |
| Rated Output | 6000VA option: 5400W; 10000VA option: 9000W |
| Output Power Factor | 0.9 lagging |
| Input | |
| Listed Configuration | Single-phase input and single-phase output; line, neutral and protective earth |
| Voltage Range | 160–280V AC; the 160–176V portion is limited to 75% load or less |
| Input Power Factor | Up to 0.99 at 100% linear load |
| Connection | Hardwired input; suitable electrical installation required |
| Output | |
| Waveform | Pure sine wave |
| Selectable Voltage | 220 / 230 / 240V AC; other regional voltage configurations must be confirmed separately |
| Voltage Regulation | ±2% |
| Frequency | 50 / 60Hz with configurable synchronisation range |
| Battery Transfer | 0ms between normal online operation and battery operation |
| Crest Factor | 3:1 acceptable |
| Connection | Hardwired output; socket boxes and bypass assemblies are separate options |
| Battery System | |
| Battery Inclusion | No batteries in the listed RT power module; compatible external battery bank required and sold separately |
| Required Battery Voltage | 240V DC |
| Compatible Battery Option | BBC20J0000 external battery module with 20 × 12V 9Ah batteries; separate purchase for the listed 6–10kVA arrangement |
| Battery Type | Sealed lead-acid, maintenance-free |
| Recharge Reference | Approximately 4 hours to 90% for the manufacturer’s standard battery arrangement; battery-bank configuration changes charging requirements |
| Cold Start | Supported with the correct charged battery system connected |
| Runtime | Depends on the selected bank, actual load, battery age and temperature; no fixed runtime promised |
| Monitoring and Management | |
| Display | LCD/LED operating status with input/output voltage and frequency, load percentage, battery voltage and internal temperature |
| Standard Interfaces | RS-232 and EPO in the regional brochure configuration |
| Optional Interfaces | Compatible SNMP/Web, USB, RS-485 and dry-contact cards; options are not assumed included or simultaneously usable |
| Protection and Alarms | Overload, short circuit, excessive temperature, battery-low and system-fault indications |
| Operating Modes | Normal online, ECO and supported frequency-converter operation |
| Rack and Physical | |
| UPS Module W × H × D | 6000VA: 440 × 88 × 680mm, 2U; 10000VA: 440 × 132 × 680mm, 3U |
| Separate Battery Module | 440 × 132 × 680mm, 3U, additional to the UPS power module |
| Combined Rack Allocation | With one listed 3U bank: 5U for6000VA; 6U for10000VA, before additional clearance and accessories |
| Installation Support | Allow for separate heavy power and battery modules, suitable shelf/rail support, ventilation and cable access |
| Environment | |
| Operating Temperature | 0–40°C |
| Operating Humidity | Up to 95% RH, non-condensing |
| Altitude | Up to 2000m at 40°C; up to 3000m at 35°C, per manufacturer conditions |
| Acoustic Noise | Below 50dB at 1m, per manufacturer conditions |