Ubiquiti UA-Retrofit-Hub-2 Two-Door Access Controller
A Clear Upgrade Path for Existing Doors Bring existing door hardware into a more organised access system with the UniFi Retrofit Hub 2. This compact DC-powered controller supports two doors, compatible OSDP or Wiegand readers, and the inputs needed to understand exit requests and door position. It is designed for installations where the existing cabling and lock arrangement deserve a careful upgrade rather than a complete restart. Highlights Two Doors Under One Controller Supports entry and exit control for up to two doors. Managed through UniFi Access with a published 10,000-user capacity. Keep Useful Existing Hardware Supports compatible Wiegand readers and UniFi Retrofit Readers. Dedicated request-to-exit, door-position and emergency inputs. Flexible Lock Circuits Powered 12 V/24 V lock outputs or suitable dry-relay control. Included DIN-rail mounting for an organised indoor installation. Key Features Reuse With a Proper Assessment Wiegand and OSDP support gives the installation team a route for retaining compatible readers and suitable existing wiring. Reader type, cable distance and the lock circuit should be reviewed together. Reusing a cable does not automatically establish that every connected component is compatible. Manage Door Events Together The controller supports two doors with reader connections, exit-request inputs and door-position inputs, plus an emergency input. These connections let the access configuration reflect the doorway rather than only recording a credential presentation. UniFi Access provides the management layer for the configured system. Match the Lock Supply The controller accepts 12 V or 24 V DC. Powered lock outputs support 12 V at up to 1 A or 24 V at up to 0.5 A, while dry relays support compatible externally powered circuits within their rating. The lock type and its required fail-safe or fail-secure behaviour must be matched during installation. Use the Correct Reader Family Compatible Models: UniFi Retrofit Reader UA-Retrofit-Reader. The hub also supports compatible third-party Wiegand readers. The standard Retrofit Reader is available separately; check each intended reader protocol and wiring diagram before specifying additional devices. Keep the Control Cabinet Tidy The 140 × 120 × 45 mm housing and included DIN-rail mount suit an indoor control cabinet. Two 10/100 MbE RJ45 ports provide network connectivity. These are network interfaces, not a substitute for the controller’s required DC power supply. Allow for the Complete System A suitable DC supply, readers, locks, door contacts and exit devices are selected separately. Size the supply and cables for the connected loads, and follow the approved emergency-release and door-control design. The hub’s 50 W maximum consumption figure must not be confused with the rating of an individual lock output. Summary The Retrofit Hub 2 provides a considered route to UniFi Access for existing doors. Its reader support, separate door inputs and flexible relay arrangements help the installation match the hardware already in place while keeping control and management together. Frequently Asked Questions Can It Control Two Doors?ExpandCollapse Yes. It supports up to two doors, with reader, exit-request and door-position connections. The complete wiring and access configuration depend on the installation. Will My Existing Wiegand Reader Work?ExpandCollapse It supports compatible third-party Wiegand readers. Confirm the reader’s protocol, supply and connections before retaining it. Is the Power Supply Included?ExpandCollapse The hub requires a suitable 12 V or 24 V DC supply selected for the system. Do not assume the optional power supply or door locks are included. Can It Power a Door Lock?ExpandCollapse Its powered outputs support 12 V DC up to 1 A or 24 V DC up to 0.5 A. Suitable dry-relay control is also available within the stated rating; the lock and emergency-release design must be checked. Can I Install It Outdoors?ExpandCollapse The controller is specified for indoor use. Install it in an appropriate protected indoor location and follow the published temperature and humidity limits.
Add-ons (1)
Pickup available at 3005, Ubi Avenue 3, #01-88
Usually ready in 2-4 Business Day (Excluding Public Holiday)
Ubiquiti UA-Retrofit-Hub-2 Two-Door Access Controller
Description
A Clear Upgrade Path for Existing Doors
Bring existing door hardware into a more organised access system with the UniFi Retrofit Hub 2. This compact DC-powered controller supports two doors, compatible OSDP or Wiegand readers, and the inputs needed to understand exit requests and door position. It is designed for installations where the existing cabling and lock arrangement deserve a careful upgrade rather than a complete restart.
Highlights
Two Doors Under One Controller
- Supports entry and exit control for up to two doors.
- Managed through UniFi Access with a published 10,000-user capacity.
Keep Useful Existing Hardware
- Supports compatible Wiegand readers and UniFi Retrofit Readers.
- Dedicated request-to-exit, door-position and emergency inputs.
Flexible Lock Circuits
- Powered 12 V/24 V lock outputs or suitable dry-relay control.
- Included DIN-rail mounting for an organised indoor installation.
Key Features
Reuse With a Proper Assessment
Wiegand and OSDP support gives the installation team a route for retaining compatible readers and suitable existing wiring. Reader type, cable distance and the lock circuit should be reviewed together. Reusing a cable does not automatically establish that every connected component is compatible.
Manage Door Events Together
The controller supports two doors with reader connections, exit-request inputs and door-position inputs, plus an emergency input. These connections let the access configuration reflect the doorway rather than only recording a credential presentation. UniFi Access provides the management layer for the configured system.
Match the Lock Supply
The controller accepts 12 V or 24 V DC. Powered lock outputs support 12 V at up to 1 A or 24 V at up to 0.5 A, while dry relays support compatible externally powered circuits within their rating. The lock type and its required fail-safe or fail-secure behaviour must be matched during installation.
Use the Correct Reader Family
Compatible Models: UniFi Retrofit Reader UA-Retrofit-Reader. The hub also supports compatible third-party Wiegand readers. The standard Retrofit Reader is available separately; check each intended reader protocol and wiring diagram before specifying additional devices.
Keep the Control Cabinet Tidy
The 140 × 120 × 45 mm housing and included DIN-rail mount suit an indoor control cabinet. Two 10/100 MbE RJ45 ports provide network connectivity. These are network interfaces, not a substitute for the controller’s required DC power supply.
Allow for the Complete System
A suitable DC supply, readers, locks, door contacts and exit devices are selected separately. Size the supply and cables for the connected loads, and follow the approved emergency-release and door-control design. The hub’s 50 W maximum consumption figure must not be confused with the rating of an individual lock output.
Summary
The Retrofit Hub 2 provides a considered route to UniFi Access for existing doors. Its reader support, separate door inputs and flexible relay arrangements help the installation match the hardware already in place while keeping control and management together.
Frequently Asked Questions
Can It Control Two Doors?
Yes. It supports up to two doors, with reader, exit-request and door-position connections. The complete wiring and access configuration depend on the installation.
Will My Existing Wiegand Reader Work?
It supports compatible third-party Wiegand readers. Confirm the reader’s protocol, supply and connections before retaining it.
Is the Power Supply Included?
The hub requires a suitable 12 V or 24 V DC supply selected for the system. Do not assume the optional power supply or door locks are included.
Can It Power a Door Lock?
Its powered outputs support 12 V DC up to 1 A or 24 V DC up to 0.5 A. Suitable dry-relay control is also available within the stated rating; the lock and emergency-release design must be checked.
Can I Install It Outdoors?
The controller is specified for indoor use. Install it in an appropriate protected indoor location and follow the published temperature and humidity limits.
Specs
Ubiquiti UA-Retrofit-Hub-2 Two-Door Access Controller
The UniFi Retrofit Hub 2 is an indoor DC-powered access controller for up to two doors. It combines compatible Wiegand or UniFi Retrofit Reader connections with lock relays, exit-request inputs, door-position inputs and an emergency input. The controller is managed through UniFi Access and includes a DIN-rail mounting arrangement. Select the DC supply, readers and lock hardware separately, with their voltage, current, cabling and emergency-release requirements checked as one complete door system.
| Specification | Details |
|---|---|
| Control and Connectivity | |
| Doors and Users | Up to 2 doors; up to 10,000 users |
| Readers | Compatible Wiegand readers and UniFi Retrofit Reader UA-Retrofit-Reader |
| Inputs | 2 reader connections; 2 exit-request inputs; 2 door-position inputs; 1 emergency input |
| Network | 2 × 10/100 MbE RJ45 ports |
| Management | UniFi Access |
| Power and Relays | |
| Input Supply | 12 V or 24 V DC; suitable supply required separately |
| Maximum Consumption | 50 W |
| Powered Lock Output | 12 V DC up to 1 A or 24 V DC up to 0.5 A |
| Dry Relay Ratings | Lock and auxiliary relays rated 30 V DC up to 1 A |
| Reader Supply | 12 V DC up to 0.5 A |
| Controls | Factory-reset button; 12 V/dry/24 V selector switches |
| Installation and Environment | |
| Dimensions | 140 × 120 × 45 mm |
| Device Weight | 420 g |
| Construction | Polycarbonate enclosure; SGCC steel mounting parts |
| Mounting | DIN-rail mount included; indoor use |
| Operating Temperature | −10 to 40 °C |
| Operating Humidity | 5–90% non-condensing |