Ablerex ARES Plus RT Rack/Tower Online UPS
Controlled online power for the systems you rely on Ablerex ARES Plus RT combines online double-conversion power protection with a rack/tower format for a flexible equipment-room installation. Pure sine-wave output and a 0.9 output power factor make it a practical option for a correctly sized NAS, server or network installation. Choose the UPS around the equipment that must stay powered long enough to complete its work or shut down safely. Local communication supports a managed shutdown workflow when paired with compatible software, while an optional network-management card provides a route to network monitoring. Highlights Continuous conditioning Online double-conversion topology Pure sine-wave output and 0.9 output power factor Fit the equipment space Rack/tower convertible installation USB, RS232 and EPO connections Build a managed response Optional compatible SNMP network card Load-based battery-runtime planning Key Features Online double conversion The inverter supplies a controlled AC output in normal online operation, isolating the protected load from many incoming mains variations. Choose the operating mode deliberately: economy and bypass operation have different power paths from the normal double-conversion mode. A defined load budget Match both the VA and watt limits to the connected equipment, leaving appropriate headroom. Include the NAS, switch and essential network devices you need during shutdown, and check the runtime at that combined load. Monitoring that fits the installation USB and RS232 allow supported local monitoring. An optional, compatible network-management card can add network visibility. Automated host shutdown requires the correct software or NAS integration and a tested end-to-end configuration. Battery care over the service life Battery performance changes with temperature, age and use. Provide ventilation, test the shutdown procedure and arrange appropriate battery inspection or replacement rather than treating the UPS as an install-and-forget device. Use the rack or tower orientation A convertible format supports different equipment layouts. Confirm the rack depth, load support, cable access and any required rails for the selected unit. The manufacturer family photographs may show an optional battery cabinet, which is separate from the UPS hardware. Compatible Models NAS, server and networking loads within the selected VA/watt limits and the supplied electrical connection requirements. CY504B is the supported ARES Plus family network-management option where the matching slot/firmware is present. Confirm exact NAS/server shutdown integration separately. The MSII BBC20 battery cabinet is not an ARES Plus battery option. Summary ARES Plus RT combines pure sine-wave online power protection with a practical rack/tower installation. Size it against the actual load, choose the required monitoring options and validate the battery-runtime and shutdown plan for your system. Frequently asked questions Is this an online double-conversion UPS?ExpandCollapse Yes. ARES Plus uses online double-conversion topology with pure sine-wave output. Economy and bypass modes use different power paths from standard online operation. What does the 0.9 output power factor mean?ExpandCollapse The real-power limit is 90%of the apparent-power rating. The selected load must remain within both limits, with appropriate operating headroom. How much backup time will I get?ExpandCollapse Runtime depends on the actual connected load, battery condition, temperature and the selected battery configuration. Size the UPS for both its VA and watt limits, then check the runtime required for shutdown or short power interruptions. Can it shut down a NAS or server automatically?ExpandCollapse Automatic shutdown requires a supported communication interface and compatible software or NAS integration. Check the exact host support and test the complete shutdown and restart sequence during commissioning. Is the network-management card included?ExpandCollapse No. The compatible CY504B network-management card is optional. Confirm the exact UPS communication slot and supported firmware when selecting it. Are external batteries or rack rails included?ExpandCollapse The listing is for the UPS hardware. External battery cabinets, compatible rails and installation are separate. Family photographs may show an optional battery cabinet or display arrangement.
Add-ons (1)
Pickup available at 3005, Ubi Avenue 3, #01-88
Usually ready in 2-4 Business Day (Excluding Public Holiday)
Ablerex ARES Plus RT Rack/Tower Online UPS
Description
Controlled online power for the systems you rely on
Ablerex ARES Plus RT combines online double-conversion power protection with a rack/tower format for a flexible equipment-room installation. Pure sine-wave output and a 0.9 output power factor make it a practical option for a correctly sized NAS, server or network installation.
Choose the UPS around the equipment that must stay powered long enough to complete its work or shut down safely. Local communication supports a managed shutdown workflow when paired with compatible software, while an optional network-management card provides a route to network monitoring.
Highlights
Continuous conditioning
- Online double-conversion topology
- Pure sine-wave output and 0.9 output power factor
Fit the equipment space
- Rack/tower convertible installation
- USB, RS232 and EPO connections
Build a managed response
- Optional compatible SNMP network card
- Load-based battery-runtime planning
Key Features
Online double conversion
The inverter supplies a controlled AC output in normal online operation, isolating the protected load from many incoming mains variations. Choose the operating mode deliberately: economy and bypass operation have different power paths from the normal double-conversion mode.
A defined load budget
Match both the VA and watt limits to the connected equipment, leaving appropriate headroom. Include the NAS, switch and essential network devices you need during shutdown, and check the runtime at that combined load.
Monitoring that fits the installation
USB and RS232 allow supported local monitoring. An optional, compatible network-management card can add network visibility. Automated host shutdown requires the correct software or NAS integration and a tested end-to-end configuration.
Battery care over the service life
Battery performance changes with temperature, age and use. Provide ventilation, test the shutdown procedure and arrange appropriate battery inspection or replacement rather than treating the UPS as an install-and-forget device.
Use the rack or tower orientation
A convertible format supports different equipment layouts. Confirm the rack depth, load support, cable access and any required rails for the selected unit. The manufacturer family photographs may show an optional battery cabinet, which is separate from the UPS hardware.
Compatible Models
NAS, server and networking loads within the selected VA/watt limits and the supplied electrical connection requirements. CY504B is the supported ARES Plus family network-management option where the matching slot/firmware is present. Confirm exact NAS/server shutdown integration separately. The MSII BBC20 battery cabinet is not an ARES Plus battery option.
Summary
ARES Plus RT combines pure sine-wave online power protection with a practical rack/tower installation. Size it against the actual load, choose the required monitoring options and validate the battery-runtime and shutdown plan for your system.
Frequently asked questions
Is this an online double-conversion UPS?
Yes. ARES Plus uses online double-conversion topology with pure sine-wave output. Economy and bypass modes use different power paths from standard online operation.
What does the 0.9 output power factor mean?
The real-power limit is 90%of the apparent-power rating. The selected load must remain within both limits, with appropriate operating headroom.
How much backup time will I get?
Runtime depends on the actual connected load, battery condition, temperature and the selected battery configuration. Size the UPS for both its VA and watt limits, then check the runtime required for shutdown or short power interruptions.
Can it shut down a NAS or server automatically?
Automatic shutdown requires a supported communication interface and compatible software or NAS integration. Check the exact host support and test the complete shutdown and restart sequence during commissioning.
Is the network-management card included?
No. The compatible CY504B network-management card is optional. Confirm the exact UPS communication slot and supported firmware when selecting it.
Are external batteries or rack rails included?
The listing is for the UPS hardware. External battery cabinets, compatible rails and installation are separate. Family photographs may show an optional battery cabinet or display arrangement.
Specs
Ablerex ARES Plus RT Rack/Tower Online UPS
Online double-conversion power protection with pure sine-wave output for matched business IT loads. Select the capacity against both VA and watts and use the actual load to establish the required battery runtime. Communication and shutdown behaviour depend on the connected equipment and software. Installation space, connections and any separate battery or mounting accessories must match the selected hardware.
| Specification | Details |
|---|---|
| UPS and Capacity | |
| Topology | Online double conversion |
| Rated capacity | 1000 VA / 900 W; 3000 VA / 2700 W |
| Output power factor | 0.9 |
| Input and Output | |
| Nominal input/output | Single-phase 220/ 230/ 240 V AC |
| Output voltage regulation | ±1% |
| Output frequency | 50/ 60 Hz |
| Battery output waveform | Pure sine wave |
| Monitoring and Management | |
| Local communication | USB and RS232 |
| Emergency power off | EPO connection |
| Network management | Optional compatible SNMP card; sold separately |
| Shutdown integration | Requires compatible host software and a tested configuration |
| Battery and Display | |
| Battery chemistry | Sealed maintenance-free VRLA lead-acid |
| Battery system | 1 kVA: 36 V; 3 kVA: 72 V for the listed standard versions |
| Runtime | Depends on load, battery condition and installed battery configuration |
| Operating display | LED/LCD arrangement depends on the supplied version |
| External battery cabinet | Optional compatible cabinet only; shown accessories are not automatically included |
| Physical Format | |
| Installation | Rack/tower convertible; UPS enclosure 2 U for listed versions |
| Dimensions W × H × D | 1 kVA: 440×88×405 mm; 3 kVA: 440×88×600 mm |
| Net weight | Approximately 14.5 kg / 27 kg respectively |
| Mounting | Confirm compatible rails or support hardware separately |
| Installation and Environment | |
| Runtime | Depends on connected load and battery configuration |
| Operating temperature | 0–40°C |
| Installation scope | UPS hardware; mounting accessories, electrical work and commissioning agreed separately |