Ablerex L Series Line-Interactive UPS
Keep everyday equipment ready for a controlled shutdown The Ablerex L Series combines battery backup and automatic voltage regulation in a compact tower UPS. It gives a workstation, compatible NAS or small network a window to respond when mains power fails, helping you close work or complete a planned shutdown instead of relying on an abrupt loss of power. Automatic voltage regulation corrects supported mains fluctuations without drawing on the battery for every voltage change. Select the capacity against the real load in watts as well as VA, and allow headroom for connected equipment. The simulated sine-wave battery output should be checked against the requirements of sensitive or active-PFC equipment. Highlights Practical power protection Line-interactive design with automatic voltage regulation Battery backup with a typical 2–6 ms transfer time A compact installation Freestanding tower enclosure USB communication for compatible monitoring and shutdown software Clear operating feedback LED status indicators and audible battery alarms Cold start and sealed maintenance-free VRLA batteries Key Features Respond to a mains interruption Battery operation supplies the supported load during an interruption so that a compatible system can shut down in an orderly way. It is best planned around the work you need to finish or the shutdown time you need, rather than an assumed fixed runtime. Handle supported voltage variation The automatic voltage regulator increases or reduces supported input voltage while the UPS remains on mains. This helps reserve battery capacity for a power interruption rather than using it for every correctable voltage fluctuation. Make shutdown part of the setup USB communication can link the UPS to compatible monitoring software. For a NAS or server, confirm the exact host support and configure the shutdown threshold, notification and restart behaviour before putting the system into service. Choose the right output waveform The L Series uses simulated sine-wave output in battery mode. Check the power-supply requirements of the equipment you intend to protect; loads requiring pure sine-wave power should use a suitable alternative UPS. Plan the small details that make it work Check plug and outlet type, cable reach, ventilation and load distribution. Maintain current data backups and periodically test the battery and shutdown procedure as part of normal system care. Compatible Models Workstations, networking equipment and NAS or server systems whose load, input supply and simulated sine-wave requirements match the selected UPS. Automatic shutdown depends on verified host/software support; this is not a universal NAS compatibility claim. Summary Choose the L Series for straightforward battery backup and voltage regulation around everyday IT equipment. Match the VA and watt ratings, confirm the waveform and connection requirements, and build a tested shutdown routine around the actual load. Product views are illustrative. Enclosure and connection details vary with the selected configuration. Frequently asked questions What type of UPS is the L Series?ExpandCollapse It is a line-interactive tower UPS with automatic voltage regulation and simulated sine-wave output in battery mode. Does it provide pure sine-wave battery output?ExpandCollapse No. Battery output is simulated sine wave. Check the requirements of active-PFC and other sensitive loads before choosing this UPS. How much backup time will I get?ExpandCollapse Runtime depends on the actual connected load, battery condition, temperature and the selected battery configuration. Size the UPS for both its VA and watt limits, then check the runtime required for shutdown or short power interruptions. Can it shut down a NAS or server automatically?ExpandCollapse Automatic shutdown requires a supported communication interface and compatible software or NAS integration. Check the exact host support and test the complete shutdown and restart sequence during commissioning. How should I look after the battery?ExpandCollapse Keep the UPS ventilated and within its operating temperature range. Test the shutdown procedure periodically and arrange appropriate inspection or replacement when battery performance declines. Batteries should be handled and recycled correctly. Are installation and additional accessories included?ExpandCollapse This is a UPS hardware listing. Any optional network card, external battery cabinet, rack rails, electrical work or commissioning must be selected or agreed separately.
3005, Ubi Avenue 3, #01-88で受け取り可能
通常2〜4日で準備が完了します
Ablerex L Series Line-Interactive UPS
商品説明
Keep everyday equipment ready for a controlled shutdown
The Ablerex L Series combines battery backup and automatic voltage regulation in a compact tower UPS. It gives a workstation, compatible NAS or small network a window to respond when mains power fails, helping you close work or complete a planned shutdown instead of relying on an abrupt loss of power.
Automatic voltage regulation corrects supported mains fluctuations without drawing on the battery for every voltage change. Select the capacity against the real load in watts as well as VA, and allow headroom for connected equipment. The simulated sine-wave battery output should be checked against the requirements of sensitive or active-PFC equipment.
Highlights
Practical power protection
- Line-interactive design with automatic voltage regulation
- Battery backup with a typical 2–6 ms transfer time
A compact installation
- Freestanding tower enclosure
- USB communication for compatible monitoring and shutdown software
Clear operating feedback
- LED status indicators and audible battery alarms
- Cold start and sealed maintenance-free VRLA batteries
Key Features
Respond to a mains interruption
Battery operation supplies the supported load during an interruption so that a compatible system can shut down in an orderly way. It is best planned around the work you need to finish or the shutdown time you need, rather than an assumed fixed runtime.
Handle supported voltage variation
The automatic voltage regulator increases or reduces supported input voltage while the UPS remains on mains. This helps reserve battery capacity for a power interruption rather than using it for every correctable voltage fluctuation.
Make shutdown part of the setup
USB communication can link the UPS to compatible monitoring software. For a NAS or server, confirm the exact host support and configure the shutdown threshold, notification and restart behaviour before putting the system into service.
Choose the right output waveform
The L Series uses simulated sine-wave output in battery mode. Check the power-supply requirements of the equipment you intend to protect; loads requiring pure sine-wave power should use a suitable alternative UPS.
Plan the small details that make it work
Check plug and outlet type, cable reach, ventilation and load distribution. Maintain current data backups and periodically test the battery and shutdown procedure as part of normal system care.
Compatible Models
Workstations, networking equipment and NAS or server systems whose load, input supply and simulated sine-wave requirements match the selected UPS. Automatic shutdown depends on verified host/software support; this is not a universal NAS compatibility claim.
Summary
Choose the L Series for straightforward battery backup and voltage regulation around everyday IT equipment. Match the VA and watt ratings, confirm the waveform and connection requirements, and build a tested shutdown routine around the actual load.
Product views are illustrative. Enclosure and connection details vary with the selected configuration.
Frequently asked questions
What type of UPS is the L Series?
It is a line-interactive tower UPS with automatic voltage regulation and simulated sine-wave output in battery mode.
Does it provide pure sine-wave battery output?
No. Battery output is simulated sine wave. Check the requirements of active-PFC and other sensitive loads before choosing this UPS.
How much backup time will I get?
Runtime depends on the actual connected load, battery condition, temperature and the selected battery configuration. Size the UPS for both its VA and watt limits, then check the runtime required for shutdown or short power interruptions.
Can it shut down a NAS or server automatically?
Automatic shutdown requires a supported communication interface and compatible software or NAS integration. Check the exact host support and test the complete shutdown and restart sequence during commissioning.
How should I look after the battery?
Keep the UPS ventilated and within its operating temperature range. Test the shutdown procedure periodically and arrange appropriate inspection or replacement when battery performance declines. Batteries should be handled and recycled correctly.
Are installation and additional accessories included?
This is a UPS hardware listing. Any optional network card, external battery cabinet, rack rails, electrical work or commissioning must be selected or agreed separately.
仕様
Ablerex L Series Line-Interactive UPS
A compact line-interactive UPS for matched IT loads, with automatic voltage regulation and battery operation. The selection must satisfy both the apparent-power and real-power limits. Runtime varies with load and battery condition, and automatic shutdown depends on the connected equipment and software. Confirm the required plug, outlet and waveform before installation.
| Specification | Details |
|---|---|
| Power Protection | |
| Topology | Line-interactive with automatic voltage regulation |
| Rated capacity | 800 VA / 350 W; 1500 VA / 600 W; 2200 VA / 1000 W |
| Battery output waveform | Simulated sine wave |
| Typical transfer time | 2–6 ms |
| Input and Output | |
| Input window | 160–290 V AC |
| Input frequency | 45–65 Hz; automatic sensing |
| Battery output voltage | 220/ 230/ 240 V AC, ±10% |
| Battery output frequency | 50/ 60 Hz, ±1 Hz |
| Output connections | IEC outlet configurations are available; match the supplied regional connector arrangement |
| Battery and Runtime | |
| Battery type | Sealed maintenance-free lead-acid VRLA |
| Battery configuration | 800 VA: 1×12 V 7 Ah; 1500 VA: 2×12 V 7 Ah; 2200 VA: 2×12 V 9 Ah |
| Recharge time | Typically 4–6 hours to 90% |
| Cold start | Supported |
| Runtime | Load- and battery-dependent; check the required shutdown window |
| Monitoring and Protection | |
| Communication | USB standard; optional RS232 |
| Display | LED operating, battery and fault status; larger models also show load/battery level |
| Audible alarms | Battery operation and low-battery warning |
| Protection | Overload and short-circuit protection |
| Physical and Environment | |
| Installation | Freestanding tower |
| Dimensions W × H × D | 800 VA: 100×140×292 mm; 1500/ 2200 VA: 148×198×315 mm |
| Net weight | 4.5 kg / 8 kg / 12 kg respectively |
| Operating temperature | 0–40°C |
| Humidity | Up to 95%RH, non-condensing |
| Noise | ≤40 dB |
| Altitude | Up to 1000 m without derating |