ホーム アクセサリー UPS Ablerex ABX RT Rack/Tower Online UPS
Ablerex ABX RT 常時インバーター方式 UPS 製品群の画像。容量により筐体が異なります
-21%新着

Ablerex ABX RT Rack/Tower Online UPS

Online power protection with a clear real-power budget The Ablerex ABX RT is an online double-conversion UPS with a 1.0 output power factor. Its VA and watt ratings are matched, making it straightforward to plan a protected IT load while still leaving headroom for normal operating conditions and growth. Pure sine-wave output, local management interfaces and an optional communication-card slot provide the foundations for a managed power-protection installation. Select the exact capacity and configuration against the electrical supply, battery runtime and equipment space required by your NAS, server or network. Highlights Online protection Double-conversion topology and pure sine-wave output 1.0 output power factor A defined installation Rack/tower configuration Match capacity, input/output connections and mounting space Monitoring and response USB and RS232 communication Optional compatible SNMP or dry-contact card Key Features Online double conversion The inverter supplies a controlled AC output in normal online operation, isolating the protected load from many incoming mains variations. Choose the operating mode deliberately: economy and bypass operation have different power paths from the normal double-conversion mode. A defined load budget Match both the VA and watt limits to the connected equipment, leaving appropriate headroom. Include the NAS, switch and essential network devices you need during shutdown, and check the runtime at that combined load. Monitoring that fits the installation USB and RS232 allow supported local monitoring. An optional, compatible network-management card can add network visibility. Automated host shutdown requires the correct software or NAS integration and a tested end-to-end configuration. Battery care over the service life Battery performance changes with temperature, age and use. Provide ventilation, test the shutdown procedure and arrange appropriate battery inspection or replacement rather than treating the UPS as an install-and-forget device. Plan the exact physical configuration Capacity and hardware revision can change the enclosure height, depth and connection arrangement. Confirm the selected configuration and mounting requirements before installation; a family photograph does not establish a common chassis size across every option. Compatible Models Matched NAS, server and networking loads within the selected VA/watt limits and supplied electrical connection requirements. The ABX-specific RC67501 communication option is separate from the ARES Plus/MSII CY504B card. Confirm exact interface and shutdown support before installation. Summary ABX RT provides pure sine-wave online power protection and a 1.0 output power factor for a correctly specified IT installation. Match the physical configuration, connected load, monitoring requirements and shutdown window before deployment. Frequently asked questions What is the output power factor?ExpandCollapse The ABX range has a 1.0 output power factor, so its VA and watt ratings match. Keep the connected load within the selected limits and leave appropriate headroom. Does it provide pure sine-wave output?ExpandCollapse Yes. The ABX online double-conversion design provides pure sine-wave output. How much backup time will I get?ExpandCollapse Runtime depends on the actual connected load, battery condition, temperature and the selected battery configuration. Size the UPS for both its VA and watt limits, then check the runtime required for shutdown or short power interruptions. Can it shut down a NAS or server automatically?ExpandCollapse Automatic shutdown requires a supported communication interface and compatible software or NAS integration. Check the exact host support and test the complete shutdown and restart sequence during commissioning. Which network-management card should I choose?ExpandCollapse Use the ABX-specific compatible card, identified in the range as RC67501. Do not assume that the CY504B card used by other Ablerex UPS families is interchangeable. Are installation and additional accessories included?ExpandCollapse This is a UPS hardware listing. Any optional network card, external battery cabinet, rack rails, electrical work or commissioning must be selected or agreed separately.

通常価格 $1,054.55 SGD セール価格 $828.57 SGD
$225.98 SGDお得
Capacity: 1000VA /1000W

Error product group when enable variant picker

お気に入りに追加
比較に追加

American Express
Apple Pay
Google Pay
Mastercard
PayPal
Shop Pay
Visa
Capacity: 1000VA /1000W, 3000VA /3000W
ブランド: Ablerex
SKU: ABX1000RT 在庫状況: 在庫あり
カテゴリー: Ablerex UPS 新着商品

3005, Ubi Avenue 3, #01-88で受け取り可能

通常2〜4日で準備が完了します

Ablerex ABX RT 常時インバーター方式 UPS 製品群の画像。容量により筐体が異なります

Ablerex ABX RT Rack/Tower Online UPS

Capacity: 1000VA /1000W

  • 3005, Ubi Avenue 3, #01-88

    受取が可能です, 通常2〜4日で準備が完了します

    3005, Ubi Avenue 3, #01-88
    Singapore 408861
    シンガポール

    +6561007000

    Google マップで確認
Ablerex ABX RT 常時インバーター方式 UPS 製品群の画像。容量により筐体が異なります

Ablerex ABX RT Rack/Tower Online UPS

通常価格 $1,054.55 SGD セール価格 $828.57 SGD
複数の仕様をまとめて注文

各仕様の数量を設定すると、カートが自動的に更新されます。

バリエーション

数量

価格

バリエーションの合計額

Variants

1000VA /1000W

価格

セール価格$828.57 SGD

バリエーションの合計額

$0.00 SGD
3000VA /3000W

価格

セール価格$1,171.43 SGD

バリエーションの合計額

$0.00 SGD
0

アイテムの総数

$0.00 SGD
0

アイテムの総数

商品の小計

Taxes and shipping calculated at checkout
カートを見る
商品説明

Online power protection with a clear real-power budget

The Ablerex ABX RT is an online double-conversion UPS with a 1.0 output power factor. Its VA and watt ratings are matched, making it straightforward to plan a protected IT load while still leaving headroom for normal operating conditions and growth.

Pure sine-wave output, local management interfaces and an optional communication-card slot provide the foundations for a managed power-protection installation. Select the exact capacity and configuration against the electrical supply, battery runtime and equipment space required by your NAS, server or network.

Highlights

Online protection

  • Double-conversion topology and pure sine-wave output
  • 1.0 output power factor

A defined installation

  • Rack/tower configuration
  • Match capacity, input/output connections and mounting space

Monitoring and response

  • USB and RS232 communication
  • Optional compatible SNMP or dry-contact card

Key Features

Online double conversion

The inverter supplies a controlled AC output in normal online operation, isolating the protected load from many incoming mains variations. Choose the operating mode deliberately: economy and bypass operation have different power paths from the normal double-conversion mode.

A defined load budget

Match both the VA and watt limits to the connected equipment, leaving appropriate headroom. Include the NAS, switch and essential network devices you need during shutdown, and check the runtime at that combined load.

Monitoring that fits the installation

USB and RS232 allow supported local monitoring. An optional, compatible network-management card can add network visibility. Automated host shutdown requires the correct software or NAS integration and a tested end-to-end configuration.

Battery care over the service life

Battery performance changes with temperature, age and use. Provide ventilation, test the shutdown procedure and arrange appropriate battery inspection or replacement rather than treating the UPS as an install-and-forget device.

Plan the exact physical configuration

Capacity and hardware revision can change the enclosure height, depth and connection arrangement. Confirm the selected configuration and mounting requirements before installation; a family photograph does not establish a common chassis size across every option.

Compatible Models

Matched NAS, server and networking loads within the selected VA/watt limits and supplied electrical connection requirements. The ABX-specific RC67501 communication option is separate from the ARES Plus/MSII CY504B card. Confirm exact interface and shutdown support before installation.

Summary

ABX RT provides pure sine-wave online power protection and a 1.0 output power factor for a correctly specified IT installation. Match the physical configuration, connected load, monitoring requirements and shutdown window before deployment.

Frequently asked questions

What is the output power factor?

The ABX range has a 1.0 output power factor, so its VA and watt ratings match. Keep the connected load within the selected limits and leave appropriate headroom.

Does it provide pure sine-wave output?

Yes. The ABX online double-conversion design provides pure sine-wave output.

How much backup time will I get?

Runtime depends on the actual connected load, battery condition, temperature and the selected battery configuration. Size the UPS for both its VA and watt limits, then check the runtime required for shutdown or short power interruptions.

Can it shut down a NAS or server automatically?

Automatic shutdown requires a supported communication interface and compatible software or NAS integration. Check the exact host support and test the complete shutdown and restart sequence during commissioning.

Which network-management card should I choose?

Use the ABX-specific compatible card, identified in the range as RC67501. Do not assume that the CY504B card used by other Ablerex UPS families is interchangeable.

Are installation and additional accessories included?

This is a UPS hardware listing. Any optional network card, external battery cabinet, rack rails, electrical work or commissioning must be selected or agreed separately.

仕様

Ablerex ABX RT Rack/Tower Online UPS

Online double-conversion UPS hardware with a 1.0 output power factor for matched IT loads. Use the exact selected capacity, electrical connections and battery configuration when planning the installation. Physical enclosure dimensions can change with capacity and revision. Runtime depends on actual load and battery condition, and software-assisted shutdown requires a supported and tested communication setup.

SpecificationDetails
UPS and Capacity
TopologyOnline double conversion
Rated capacity1000 VA / 1000 W; 3000 VA / 3000 W
Output power factor1.0
Output waveformPure sine wave
Power and Operation
Nominal input/output220/ 230/ 240 V AC; single phase with earth
Cold startSupported
RuntimeDepends on actual load, battery condition and installed battery configuration
Monitoring and Interfaces
Local communicationUSB and RS232
DisplayGraphical LCD on the RT family
Option slotCompatible SNMP or dry-contact card; sold separately
Shutdown integrationRequires supported host software and commissioning
Battery and Installation
Standard battery chemistrySealed maintenance-free lead-acid
Battery configurationSelected standard capacity and hardware revision must be matched
Physical formatRack/tower
Mounting envelopeConfirm height, depth and mounting hardware for selected capacity/revision
Operating temperature0–40°C
ScopeUPS hardware; optional accessories, electrical work and commissioning separate

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

最近見た商品