Beranda Aksesori UPS Ablerex L Series Line-Interactive UPS
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
-31%Baru
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals
Ablerex L Series Line-Interactive UPS - ACE Peripherals

Ablerex L Series Line-Interactive UPS

Keep everyday equipment ready for a controlled shutdown The Ablerex L Series combines battery backup and automatic voltage regulation in a compact tower UPS. It gives a workstation, compatible NAS or small network a window to respond when mains power fails, helping you close work or complete a planned shutdown instead of relying on an abrupt loss of power. Automatic voltage regulation corrects supported mains fluctuations without drawing on the battery for every voltage change. Select the capacity against the real load in watts as well as VA, and allow headroom for connected equipment. The simulated sine-wave battery output should be checked against the requirements of sensitive or active-PFC equipment. Highlights Practical power protection Line-interactive design with automatic voltage regulation Battery backup with a typical 2–6 ms transfer time A compact installation Freestanding tower enclosure USB communication for compatible monitoring and shutdown software Clear operating feedback LED status indicators and audible battery alarms Cold start and sealed maintenance-free VRLA batteries Key Features Respond to a mains interruption Battery operation supplies the supported load during an interruption so that a compatible system can shut down in an orderly way. It is best planned around the work you need to finish or the shutdown time you need, rather than an assumed fixed runtime. Handle supported voltage variation The automatic voltage regulator increases or reduces supported input voltage while the UPS remains on mains. This helps reserve battery capacity for a power interruption rather than using it for every correctable voltage fluctuation. Make shutdown part of the setup USB communication can link the UPS to compatible monitoring software. For a NAS or server, confirm the exact host support and configure the shutdown threshold, notification and restart behaviour before putting the system into service. Choose the right output waveform The L Series uses simulated sine-wave output in battery mode. Check the power-supply requirements of the equipment you intend to protect; loads requiring pure sine-wave power should use a suitable alternative UPS. Plan the small details that make it work Check plug and outlet type, cable reach, ventilation and load distribution. Maintain current data backups and periodically test the battery and shutdown procedure as part of normal system care. Compatible Models Workstations, networking equipment and NAS or server systems whose load, input supply and simulated sine-wave requirements match the selected UPS. Automatic shutdown depends on verified host/software support; this is not a universal NAS compatibility claim. Summary Choose the L Series for straightforward battery backup and voltage regulation around everyday IT equipment. Match the VA and watt ratings, confirm the waveform and connection requirements, and build a tested shutdown routine around the actual load. Product views are illustrative. Enclosure and connection details vary with the selected configuration. Frequently asked questions What type of UPS is the L Series?ExpandCollapse It is a line-interactive tower UPS with automatic voltage regulation and simulated sine-wave output in battery mode. Does it provide pure sine-wave battery output?ExpandCollapse No. Battery output is simulated sine wave. Check the requirements of active-PFC and other sensitive loads before choosing this UPS. How much backup time will I get?ExpandCollapse Runtime depends on the actual connected load, battery condition, temperature and the selected battery configuration. Size the UPS for both its VA and watt limits, then check the runtime required for shutdown or short power interruptions. Can it shut down a NAS or server automatically?ExpandCollapse Automatic shutdown requires a supported communication interface and compatible software or NAS integration. Check the exact host support and test the complete shutdown and restart sequence during commissioning. How should I look after the battery?ExpandCollapse Keep the UPS ventilated and within its operating temperature range. Test the shutdown procedure periodically and arrange appropriate inspection or replacement when battery performance declines. Batteries should be handled and recycled correctly. Are installation and additional accessories included?ExpandCollapse This is a UPS hardware listing. Any optional network card, external battery cabinet, rack rails, electrical work or commissioning must be selected or agreed separately.

Harga normal $218.18 SGD Harga jual $150.00 SGD
Hemat $68.18 SGD
Capacity: 800VA / 350W

Error grup produk saat mengaktifkan pemilih varian

Tambahkan ke Daftar Keinginan
Tambah ke Perbandingan

American Express
Apple Pay
Google Pay
Mastercard
PayPal
Shop Pay
Visa
Capacity: 800VA / 350W, 1500VA / 600W, 2200VA / 1000W
Pemasok: Ablerex
SKU: 800L Ketersediaan: Tersedia

Pengambilan tersedia di 3005, Ubi Avenue 3, #01-88

Biasanya siap dalam 2-4 hari kerja (tidak termasuk hari libur)

Ablerex L Series Line-Interactive UPS - ACE Peripherals

Ablerex L Series Line-Interactive UPS

Capacity: 800VA / 350W

  • 3005, Ubi Avenue 3, #01-88

    Tersedia layanan pengambilan, biasanya siap dalam 2-4 hari kerja (tidak termasuk hari libur)

    3005, Ubi Avenue 3, #01-88
    Singapore 408861
    Singapura

    +6561007000

    Cek ini di Google Maps
Ablerex L Series Line-Interactive UPS - ACE Peripherals

Ablerex L Series Line-Interactive UPS

Harga normal $218.18 SGD Harga jual $150.00 SGD
Pesan beberapa pilihan

Atur jumlah setiap pilihan. Keranjang diperbarui secara otomatis.

Varian

Jumlah

Harga

Total varian

Varian

800VA / 350W

Harga

Harga jual$150.00 SGD

Total varian

$0.00 SGD
1500VA / 600W

Harga

Harga jual$262.50 SGD

Total varian

$0.00 SGD
2200VA / 1000W

Harga

Harga jual$320.00 SGD

Total varian

$0.00 SGD
0

Total barang

$0.00 SGD
0

Total barang

Subtotal produk

Pajak dan pengiriman dihitung saat checkout
Lihat keranjang
Deskripsi

Keep everyday equipment ready for a controlled shutdown

The Ablerex L Series combines battery backup and automatic voltage regulation in a compact tower UPS. It gives a workstation, compatible NAS or small network a window to respond when mains power fails, helping you close work or complete a planned shutdown instead of relying on an abrupt loss of power.

Automatic voltage regulation corrects supported mains fluctuations without drawing on the battery for every voltage change. Select the capacity against the real load in watts as well as VA, and allow headroom for connected equipment. The simulated sine-wave battery output should be checked against the requirements of sensitive or active-PFC equipment.

Highlights

Practical power protection

  • Line-interactive design with automatic voltage regulation
  • Battery backup with a typical 2–6 ms transfer time

A compact installation

  • Freestanding tower enclosure
  • USB communication for compatible monitoring and shutdown software

Clear operating feedback

  • LED status indicators and audible battery alarms
  • Cold start and sealed maintenance-free VRLA batteries

Key Features

Respond to a mains interruption

Battery operation supplies the supported load during an interruption so that a compatible system can shut down in an orderly way. It is best planned around the work you need to finish or the shutdown time you need, rather than an assumed fixed runtime.

Handle supported voltage variation

The automatic voltage regulator increases or reduces supported input voltage while the UPS remains on mains. This helps reserve battery capacity for a power interruption rather than using it for every correctable voltage fluctuation.

Make shutdown part of the setup

USB communication can link the UPS to compatible monitoring software. For a NAS or server, confirm the exact host support and configure the shutdown threshold, notification and restart behaviour before putting the system into service.

Choose the right output waveform

The L Series uses simulated sine-wave output in battery mode. Check the power-supply requirements of the equipment you intend to protect; loads requiring pure sine-wave power should use a suitable alternative UPS.

Plan the small details that make it work

Check plug and outlet type, cable reach, ventilation and load distribution. Maintain current data backups and periodically test the battery and shutdown procedure as part of normal system care.

Compatible Models

Workstations, networking equipment and NAS or server systems whose load, input supply and simulated sine-wave requirements match the selected UPS. Automatic shutdown depends on verified host/software support; this is not a universal NAS compatibility claim.

Summary

Choose the L Series for straightforward battery backup and voltage regulation around everyday IT equipment. Match the VA and watt ratings, confirm the waveform and connection requirements, and build a tested shutdown routine around the actual load.

Product views are illustrative. Enclosure and connection details vary with the selected configuration.

Frequently asked questions

What type of UPS is the L Series?

It is a line-interactive tower UPS with automatic voltage regulation and simulated sine-wave output in battery mode.

Does it provide pure sine-wave battery output?

No. Battery output is simulated sine wave. Check the requirements of active-PFC and other sensitive loads before choosing this UPS.

How much backup time will I get?

Runtime depends on the actual connected load, battery condition, temperature and the selected battery configuration. Size the UPS for both its VA and watt limits, then check the runtime required for shutdown or short power interruptions.

Can it shut down a NAS or server automatically?

Automatic shutdown requires a supported communication interface and compatible software or NAS integration. Check the exact host support and test the complete shutdown and restart sequence during commissioning.

How should I look after the battery?

Keep the UPS ventilated and within its operating temperature range. Test the shutdown procedure periodically and arrange appropriate inspection or replacement when battery performance declines. Batteries should be handled and recycled correctly.

Are installation and additional accessories included?

This is a UPS hardware listing. Any optional network card, external battery cabinet, rack rails, electrical work or commissioning must be selected or agreed separately.

Spesifikasi

Ablerex L Series Line-Interactive UPS

A compact line-interactive UPS for matched IT loads, with automatic voltage regulation and battery operation. The selection must satisfy both the apparent-power and real-power limits. Runtime varies with load and battery condition, and automatic shutdown depends on the connected equipment and software. Confirm the required plug, outlet and waveform before installation.

SpecificationDetails
Power Protection
TopologyLine-interactive with automatic voltage regulation
Rated capacity800 VA / 350 W; 1500 VA / 600 W; 2200 VA / 1000 W
Battery output waveformSimulated sine wave
Typical transfer time2–6 ms
Input and Output
Input window160–290 V AC
Input frequency45–65 Hz; automatic sensing
Battery output voltage220/ 230/ 240 V AC, ±10%
Battery output frequency50/ 60 Hz, ±1 Hz
Output connectionsIEC outlet configurations are available; match the supplied regional connector arrangement
Battery and Runtime
Battery typeSealed maintenance-free lead-acid VRLA
Battery configuration800 VA: 1×12 V 7 Ah; 1500 VA: 2×12 V 7 Ah; 2200 VA: 2×12 V 9 Ah
Recharge timeTypically 4–6 hours to 90%
Cold startSupported
RuntimeLoad- and battery-dependent; check the required shutdown window
Monitoring and Protection
CommunicationUSB standard; optional RS232
DisplayLED operating, battery and fault status; larger models also show load/battery level
Audible alarmsBattery operation and low-battery warning
ProtectionOverload and short-circuit protection
Physical and Environment
InstallationFreestanding tower
Dimensions W × H × D800 VA: 100×140×292 mm; 1500/ 2200 VA: 148×198×315 mm
Net weight4.5 kg / 8 kg / 12 kg respectively
Operating temperature0–40°C
HumidityUp to 95%RH, non-condensing
Noise≤40 dB
AltitudeUp to 1000 m without derating