D-Link DIS-300G-8PSW 8-Port Industrial Gigabit PoE+ Managed Switch
Industrial Connectivity With Room for the Real Installation The DIS-300G-8PSW brings 6 × 10/100/1000BASE-T ports and 2 × 100/1000 Mbps SFP slots to demanding industrial networks. Its IP30-rated metal housing, fanless cooling and −40–75°C operating range suit control cabinets, factory networks and infrastructure sites where ordinary office equipment may not be the right fit. 4 copper ports provide IEEE 802.3af/at PoE+, with up to 120 W shared power from a correctly sized DC supply. Managed VLANs, traffic priority, network redundancy and diagnostic tools help organise the installation and support fault finding. The external DC power supply is selected separately for the site, the required temperature range and any connected PoE load. Highlights Connections 6 × 10/100/1000BASE-T ports and 2 × 100/1000 Mbps SFP slots. 4 PoE+ ports and up to 120 W shared budget. Compatible optical modules are selected separately. Industrial Installation IP30 metal enclosure and fanless cooling. −40–75°C operating temperature. DIN-rail and wall-mount installation. Power and Operation Dual terminal-block inputs; 54–58 VDC for 802.3at, 48–58 VDC for 802.3af, 12–48 VDC without PoE. External DC supply is not included. Managed switching with VLANs and traffic controls. 5-year warranty. Key Features Connect the Equipment at the Edge 6 × 10/100/1000BASE-T ports and 2 × 100/1000 Mbps SFP slots. Copper links serve nearby equipment while the available optical slots extend the installation over a fibre route selected for the site. Select the cable and endpoint speed as part of the complete connection. Power Devices With a Defined Budget Up to 4 IEEE 802.3af/at ports deliver up to 30 W per port within the 120 W shared budget. The actual available PoE power depends on the external supply, input voltage and total load. Allow headroom for connected-device start-up and cable losses. Keep the Cabinet Installation Practical The IP30 metal enclosure and fanless design suit an appropriately protected industrial cabinet. The specified −40–75°C operating range gives more installation flexibility than a standard office switch. DIN-rail or wall mounting keeps the device close to the equipment it serves. The enclosure rating is not a weatherproof or waterproof rating; use the site enclosure required for the environment. Keep Traffic Organised VLANs separate services such as production, cameras and management. QoS and multicast controls help manage competing traffic on shared links, while access controls support a more deliberate security policy. These are configured functions, so the commissioning process should match the actual applications and network layout. Support Recovery and Fault Finding Ring protection, spanning tree and link aggregation provide options for a tested redundant topology. Management tools, logs and status indicators help locate an interrupted link or an abnormal power condition. Recovery performance depends on the design and configuration, rather than removing every possible interruption. Extend the Link With the Right Media The SFP interfaces use separately selected supported optical modules. Match fibre type, wavelengths, connector, distance and temperature rating at both ends. Summary The DIS-300G-8PSW combines managed industrial networking with PoE+ endpoint power and a wide operating-temperature range. Select the DC supply, installation enclosure and any optical modules for the complete site design. Frequently Asked Questions How Many Data Ports Does It Have?ExpandCollapse 6 × 10/100/1000BASE-T ports and 2 × 100/1000 Mbps SFP slots. The console is a separate management connection and is not counted as a data port. Does It Include a Power Supply?ExpandCollapse No. Select a compatible external DC supply for dual terminal-block inputs; 54–58 vdc for 802.3at, 48–58 vdc for 802.3af, 12–48 vdc without poe. The supply must also cover the required PoE load and operating temperature. Does It Power Connected Devices?ExpandCollapse Yes. 4 ports support IEEE 802.3af/at PoE+, up to 30 W per port and 120 W in total when the correct supply provides enough power. The shared budget is not available separately on every port. Can It Be Installed Outdoors?ExpandCollapse Use an appropriate protected enclosure. IP30 is a cabinet protection rating, not a waterproof outdoor rating. The switch operates from −40°C to 75°C with suitable power and installation conditions. Are Optical Modules Included?ExpandCollapse No. Select supported modules for the fibre type, distance, wavelength, connector and temperature range. The module at the other end must match the link. How Is the Switch Managed?ExpandCollapse Use the supported web interface, CLI or SNMP tools. Restrict management access, save the tested configuration and monitor the power and link status during normal operation.
추가 상품 (1)
3005, Ubi Avenue 3, #01-88에서 픽업 가능
일반적으로 2~4일 후 준비 완료
D-Link DIS-300G-8PSW 8-Port Industrial Gigabit PoE+ Managed Switch
제품 설명
Industrial Connectivity With Room for the Real Installation
The DIS-300G-8PSW brings 6 × 10/100/1000BASE-T ports and 2 × 100/1000 Mbps SFP slots to demanding industrial networks. Its IP30-rated metal housing, fanless cooling and −40–75°C operating range suit control cabinets, factory networks and infrastructure sites where ordinary office equipment may not be the right fit. 4 copper ports provide IEEE 802.3af/at PoE+, with up to 120 W shared power from a correctly sized DC supply.
Managed VLANs, traffic priority, network redundancy and diagnostic tools help organise the installation and support fault finding. The external DC power supply is selected separately for the site, the required temperature range and any connected PoE load.
Highlights
Connections
- 6 × 10/100/1000BASE-T ports and 2 × 100/1000 Mbps SFP slots.
- 4 PoE+ ports and up to 120 W shared budget.
- Compatible optical modules are selected separately.
Industrial Installation
- IP30 metal enclosure and fanless cooling.
- −40–75°C operating temperature.
- DIN-rail and wall-mount installation.
Power and Operation
- Dual terminal-block inputs; 54–58 VDC for 802.3at, 48–58 VDC for 802.3af, 12–48 VDC without PoE.
- External DC supply is not included.
- Managed switching with VLANs and traffic controls.
- 5-year warranty.
Key Features
Connect the Equipment at the Edge
6 × 10/100/1000BASE-T ports and 2 × 100/1000 Mbps SFP slots. Copper links serve nearby equipment while the available optical slots extend the installation over a fibre route selected for the site. Select the cable and endpoint speed as part of the complete connection.
Power Devices With a Defined Budget
Up to 4 IEEE 802.3af/at ports deliver up to 30 W per port within the 120 W shared budget. The actual available PoE power depends on the external supply, input voltage and total load. Allow headroom for connected-device start-up and cable losses.
Keep the Cabinet Installation Practical
The IP30 metal enclosure and fanless design suit an appropriately protected industrial cabinet. The specified −40–75°C operating range gives more installation flexibility than a standard office switch. DIN-rail or wall mounting keeps the device close to the equipment it serves. The enclosure rating is not a weatherproof or waterproof rating; use the site enclosure required for the environment.
Keep Traffic Organised
VLANs separate services such as production, cameras and management. QoS and multicast controls help manage competing traffic on shared links, while access controls support a more deliberate security policy. These are configured functions, so the commissioning process should match the actual applications and network layout.
Support Recovery and Fault Finding
Ring protection, spanning tree and link aggregation provide options for a tested redundant topology. Management tools, logs and status indicators help locate an interrupted link or an abnormal power condition. Recovery performance depends on the design and configuration, rather than removing every possible interruption.
Extend the Link With the Right Media
The SFP interfaces use separately selected supported optical modules. Match fibre type, wavelengths, connector, distance and temperature rating at both ends.
Summary
The DIS-300G-8PSW combines managed industrial networking with PoE+ endpoint power and a wide operating-temperature range. Select the DC supply, installation enclosure and any optical modules for the complete site design.
Frequently Asked Questions
How Many Data Ports Does It Have?
6 × 10/100/1000BASE-T ports and 2 × 100/1000 Mbps SFP slots. The console is a separate management connection and is not counted as a data port.
Does It Include a Power Supply?
No. Select a compatible external DC supply for dual terminal-block inputs; 54–58 vdc for 802.3at, 48–58 vdc for 802.3af, 12–48 vdc without poe. The supply must also cover the required PoE load and operating temperature.
Does It Power Connected Devices?
Yes. 4 ports support IEEE 802.3af/at PoE+, up to 30 W per port and 120 W in total when the correct supply provides enough power. The shared budget is not available separately on every port.
Can It Be Installed Outdoors?
Use an appropriate protected enclosure. IP30 is a cabinet protection rating, not a waterproof outdoor rating. The switch operates from −40°C to 75°C with suitable power and installation conditions.
Are Optical Modules Included?
No. Select supported modules for the fibre type, distance, wavelength, connector and temperature range. The module at the other end must match the link.
How Is the Switch Managed?
Use the supported web interface, CLI or SNMP tools. Restrict management access, save the tested configuration and monitor the power and link status during normal operation.
사양
D-Link DIS-300G-8PSW 8-Port Industrial Gigabit PoE+ Managed Switch
The DIS-300G-8PSW is an industrial managed switch with 8 data interfaces and a fanless IP30 metal enclosure. It supplies IEEE 802.3af/at PoE+ on 4 ports, sharing up to 120 W with a suitable external power source. SFP optics and the compatible endpoint define each fibre link. Dual DC input paths support an appropriately designed power installation. The −40–75°C operating range applies to the switch; the selected supply, modules and surrounding enclosure must also suit the site.
| Specification | Details |
|---|---|
| Interfaces | |
| Data Ports | 6 × 10/100/1000BASE-T ports and 2 × 100/1000 Mbps SFP slots |
| Copper Operation | 10/100/1000 Mbps with Auto-Negotiation and Auto-MDI/MDIX |
| PoE Output | 4 × IEEE 802.3af/at; up to 30 W per port |
| Shared PoE Budget | Up to 120 W, subject to input power and connected load |
| Optical Modules | Separate supported SFP modules required |
| Switching and Traffic | |
| Management Class | Managed |
| MAC Address Table | 8K entries |
| Jumbo Frames | 9 KB |
| Segmentation | IEEE 802.1Q VLANs; port-based VLAN controls |
| Multicast | IGMP snooping and querying |
| Maximum VLANs | 1024 |
| QoS Queues | 8 per port; SPQ and WRR |
| Multicast Groups | Up to 255 IGMP groups |
| Management and Resilience | |
| Management | Web interface, CLI and SNMP v1/v2c/v3 |
| Spanning Tree | STP, RSTP and MSTP |
| Link Aggregation | Static or LACP aggregation |
| Ring Recovery | Under 20 ms in the specified configured topology |
| Security | Port access controls, storm control and network access policies |
| Diagnostics | Logs, status monitoring and cable diagnostics |
| Power and Monitoring | |
| DC Input | Dual terminal-block inputs; 54–58 VDC for 802.3at, 48–58 VDC for 802.3af, 12–48 VDC without PoE |
| Maximum Consumption | 145 W with full 120 W PoE load; 14 W without powered devices |
| External Supply | Required separately; size for the total switch and any PoE load |
| Alarm Relay | 0.5 A at 24 VDC |
| Power Arrangement | Dual inputs support separately designed redundant DC paths |
| Physical and Environmental | |
| Enclosure | IP30-rated metal; fanless |
| Mounting | DIN rail or wall |
| Dimensions | 77 × 154 × 128 mm |
| Device Weight | 1.308 kg |
| Operating Temperature | −40–75°C |
| Storage Temperature | −40–85°C |
| Humidity | 5–95% RH, non-condensing |
| Warranty | 5 years |