Ablerex MSII-RT Online Rack Tower UPS

Ablerex MSII-RT Online Rack Tower UPS Ablerex MSII-RT provides online double-conversion power protection for server, storage and network installations that need a deliberately planned power and battery system. Its DSP-controlled power module regenerates the output supply, with pure sine-wave operation and a front LCD that makes the electrical and battery status easier to assess. These offers are UPS power modules without batteries. Add the correct external battery bank for battery backup, then plan the hardwired supply, load connection and rack support around the complete system. The separate battery architecture allows the power requirement and runtime requirement to be considered together rather than assuming one determines the other. Highlights Power Protection for Essential Equipment Online double conversion and pure sine-wave output 0.9 output power factor and no transfer interruption from normal online to battery operation LCD/LED status with electrical, load and battery information A Complete System Needs the Right Battery Bank RT power module sold without batteries Compatible external battery bank purchased separately Hardwired input/output with optional management and bypass accessories Key Features Separate Power Capacity from Runtime Select the UPS module against the equipment’s VA and watt demand, then choose the compatible battery arrangement for the shutdown or continuity window. BBC20J0000 is an external battery option for this range. Buying the power module alone does not create a working battery-backup system. Maintain a Controlled Supply Online double conversion conditions the output in normal operation, while the inverter provides pure sine-wave power. The supported battery connection allows a transition from normal online operation without a transfer interruption. This does not remove the need to protect the stored data with separate backups. See the Conditions That Matter The display shows input and output electrical values, load, battery voltage and operating status. Alarms help identify mains failure, low battery and system faults. Monitoring is most useful when the team has already agreed what to shut down, when to act and who is responsible. Build the Electrical Installation Properly The power module uses hardwired AC input and output. Suitable isolation, protective devices, earthing and load connections must be specified for the site. Optional bypass and socket-box accessories need to match the selected power rating and installation arrangement; they are not included by default. Plan the Rack as a Complete System The UPS and battery bank occupy separate rack spaces and add separate loads to the cabinet. Check usable depth, supporting hardware, ventilation and service access. Photographs of the family may show an external battery bank or a different chassis size; only the selected power module is included in this offer. Extend Monitoring with Verified Accessories The series supports optional management interfaces, including an appropriate SNMP/Web card for network monitoring and supported shutdown workflows. Confirm the card, UPS revision and host-software compatibility before deployment. Do not assume that different optional interface cards can operate together. Summary Ablerex MSII-RT is suited to a planned online UPS installation where power capacity, battery runtime and electrical integration must be considered together. Select the power module, add the verified battery bank and installation accessories, and confirm the load and shutdown arrangement before commissioning. Frequently Asked Questions Does the UPS Include Its Batteries?ExpandCollapse No. These MSII-RT offers are UPS power modules. A compatible external battery bank is required for battery backup and is purchased separately. The compatible BBC20J0000 module is the listed battery option for the offered range; the UPS price does not include that bank. How Do I Choose Between the Capacity Options?ExpandCollapse Compare both the VA and watt ratings with the measured load, including startup demand and sensible headroom. Then size the battery system for the required backup time. A larger UPS power module alone does not provide longer runtime without a suitable battery arrangement. Can I Plug It into an Ordinary Wall Socket?ExpandCollapse This is a hardwired UPS with hardwired input and output. Have the supply, isolation, protection, earthing and load connection assessed by a qualified electrical professional. An optional socket box or bypass assembly does not remove the need for a correctly designed installation. How Much Rack Space Does the Complete System Need?ExpandCollapse The smaller listed power module occupies 2U and the larger occupies 3U. The separate battery bank adds 3U, making 5U or 6U with one bank before service clearance, bypass hardware and other accessories. Check the rack’s usable depth and weight capacity as well as its available units. Can It Provide Network Monitoring or Server Shutdown?ExpandCollapse Network monitoring requires the correct optional SNMP/Web card and a supported shutdown configuration. CY504B supports the MSII series, but the supplied UPS revision, network settings and host software must still be checked. The card is not included in the UPS power-module price. How Long Will It Run During an Outage?ExpandCollapse That depends on the battery-bank configuration and actual connected load, as well as battery age and temperature. Share the equipment list and required runtime before selecting the bank. Keep an independent data backup and test the intended shutdown procedure after installation.

通常価格 $2,509.09 SGD セール価格 $1,725.00 SGD
$784.09 SGDお得
Capacity: 6000VA

Error product group when enable variant picker

お気に入りに追加
比較に追加

American Express
Apple Pay
Google Pay
Mastercard
PayPal
Shop Pay
Visa

追加商品 (3)

Capacity: 6000VA, 10000VA
ブランド: Ablerex
タイプ: UPS
SKU: MSII 6000RT 在庫状況: 在庫あり
カテゴリー: Ablerex UPS 新着商品

3005, Ubi Avenue 3, #01-88で受け取り可能

通常2〜4日で準備が完了します

Ablerex MSII-RT Online Rack Tower UPS - ACE Peripherals

Ablerex MSII-RT Online Rack Tower UPS

Capacity: 6000VA

  • 3005, Ubi Avenue 3, #01-88

    受取が可能です, 通常2〜4日で準備が完了します

    3005, Ubi Avenue 3, #01-88
    Singapore 408861
    シンガポール

    +6561007000

    Google マップで確認
Ablerex MSII-RT Online Rack Tower UPS - ACE Peripherals

Ablerex MSII-RT Online Rack Tower UPS

通常価格 $2,509.09 SGD セール価格 $1,725.00 SGD
複数の仕様をまとめて注文

各仕様の数量を設定すると、カートが自動的に更新されます。

バリエーション

数量

価格

バリエーションの合計額

Variants

6000VA

価格

セール価格$1,725.00 SGD

バリエーションの合計額

$0.00 SGD
10000VA

価格

セール価格$2,100.00 SGD

バリエーションの合計額

$0.00 SGD
0

アイテムの総数

$0.00 SGD
0

アイテムの総数

商品の小計

Taxes and shipping calculated at checkout
カートを見る
商品説明

Ablerex MSII-RT Online Rack Tower UPS

Ablerex MSII-RT provides online double-conversion power protection for server, storage and network installations that need a deliberately planned power and battery system. Its DSP-controlled power module regenerates the output supply, with pure sine-wave operation and a front LCD that makes the electrical and battery status easier to assess.

These offers are UPS power modules without batteries. Add the correct external battery bank for battery backup, then plan the hardwired supply, load connection and rack support around the complete system. The separate battery architecture allows the power requirement and runtime requirement to be considered together rather than assuming one determines the other.

Highlights

Power Protection for Essential Equipment

  • Online double conversion and pure sine-wave output
  • 0.9 output power factor and no transfer interruption from normal online to battery operation
  • LCD/LED status with electrical, load and battery information

A Complete System Needs the Right Battery Bank

  • RT power module sold without batteries
  • Compatible external battery bank purchased separately
  • Hardwired input/output with optional management and bypass accessories

Key Features

Separate Power Capacity from Runtime

Select the UPS module against the equipment’s VA and watt demand, then choose the compatible battery arrangement for the shutdown or continuity window. BBC20J0000 is an external battery option for this range. Buying the power module alone does not create a working battery-backup system.

Maintain a Controlled Supply

Online double conversion conditions the output in normal operation, while the inverter provides pure sine-wave power. The supported battery connection allows a transition from normal online operation without a transfer interruption. This does not remove the need to protect the stored data with separate backups.

See the Conditions That Matter

The display shows input and output electrical values, load, battery voltage and operating status. Alarms help identify mains failure, low battery and system faults. Monitoring is most useful when the team has already agreed what to shut down, when to act and who is responsible.

Build the Electrical Installation Properly

The power module uses hardwired AC input and output. Suitable isolation, protective devices, earthing and load connections must be specified for the site. Optional bypass and socket-box accessories need to match the selected power rating and installation arrangement; they are not included by default.

Plan the Rack as a Complete System

The UPS and battery bank occupy separate rack spaces and add separate loads to the cabinet. Check usable depth, supporting hardware, ventilation and service access. Photographs of the family may show an external battery bank or a different chassis size; only the selected power module is included in this offer.

Extend Monitoring with Verified Accessories

The series supports optional management interfaces, including an appropriate SNMP/Web card for network monitoring and supported shutdown workflows. Confirm the card, UPS revision and host-software compatibility before deployment. Do not assume that different optional interface cards can operate together.

Summary

Ablerex MSII-RT is suited to a planned online UPS installation where power capacity, battery runtime and electrical integration must be considered together. Select the power module, add the verified battery bank and installation accessories, and confirm the load and shutdown arrangement before commissioning.

Frequently Asked Questions

Does the UPS Include Its Batteries?

No. These MSII-RT offers are UPS power modules. A compatible external battery bank is required for battery backup and is purchased separately. The compatible BBC20J0000 module is the listed battery option for the offered range; the UPS price does not include that bank.

How Do I Choose Between the Capacity Options?

Compare both the VA and watt ratings with the measured load, including startup demand and sensible headroom. Then size the battery system for the required backup time. A larger UPS power module alone does not provide longer runtime without a suitable battery arrangement.

Can I Plug It into an Ordinary Wall Socket?

This is a hardwired UPS with hardwired input and output. Have the supply, isolation, protection, earthing and load connection assessed by a qualified electrical professional. An optional socket box or bypass assembly does not remove the need for a correctly designed installation.

How Much Rack Space Does the Complete System Need?

The smaller listed power module occupies 2U and the larger occupies 3U. The separate battery bank adds 3U, making 5U or 6U with one bank before service clearance, bypass hardware and other accessories. Check the rack’s usable depth and weight capacity as well as its available units.

Can It Provide Network Monitoring or Server Shutdown?

Network monitoring requires the correct optional SNMP/Web card and a supported shutdown configuration. CY504B supports the MSII series, but the supplied UPS revision, network settings and host software must still be checked. The card is not included in the UPS power-module price.

How Long Will It Run During an Outage?

That depends on the battery-bank configuration and actual connected load, as well as battery age and temperature. Share the equipment list and required runtime before selecting the bank. Keep an independent data backup and test the intended shutdown procedure after installation.

仕様

Ablerex MSII-RT Online Rack Tower UPS

Specifications describe the listed single-phase RT power modules. External batteries, management cards, bypass hardware, socket boxes and installation are separate unless specifically included.

UPS Design
TopologyOnline double conversion with DSP control
InstallationRack or tower convertible power module
Rated Output6000VA option: 5400W; 10000VA option: 9000W
Output Power Factor0.9 lagging
Input
Listed ConfigurationSingle-phase input and single-phase output; line, neutral and protective earth
Voltage Range160–280V AC; the 160–176V portion is limited to 75% load or less
Input Power FactorUp to 0.99 at 100% linear load
ConnectionHardwired input; suitable electrical installation required
Output
WaveformPure sine wave
Selectable Voltage220 / 230 / 240V AC; other regional voltage configurations must be confirmed separately
Voltage Regulation±2%
Frequency50 / 60Hz with configurable synchronisation range
Battery Transfer0ms between normal online operation and battery operation
Crest Factor3:1 acceptable
ConnectionHardwired output; socket boxes and bypass assemblies are separate options
Battery System
Battery InclusionNo batteries in the listed RT power module; compatible external battery bank required and sold separately
Required Battery Voltage240V DC
Compatible Battery OptionBBC20J0000 external battery module with 20 × 12V 9Ah batteries; separate purchase for the listed 6–10kVA arrangement
Battery TypeSealed lead-acid, maintenance-free
Recharge ReferenceApproximately 4 hours to 90% for the manufacturer’s standard battery arrangement; battery-bank configuration changes charging requirements
Cold StartSupported with the correct charged battery system connected
RuntimeDepends on the selected bank, actual load, battery age and temperature; no fixed runtime promised
Monitoring and Management
DisplayLCD/LED operating status with input/output voltage and frequency, load percentage, battery voltage and internal temperature
Standard InterfacesRS-232 and EPO in the regional brochure configuration
Optional InterfacesCompatible SNMP/Web, USB, RS-485 and dry-contact cards; options are not assumed included or simultaneously usable
Protection and AlarmsOverload, short circuit, excessive temperature, battery-low and system-fault indications
Operating ModesNormal online, ECO and supported frequency-converter operation
Rack and Physical
UPS Module W × H × D6000VA: 440 × 88 × 680mm, 2U; 10000VA: 440 × 132 × 680mm, 3U
Separate Battery Module440 × 132 × 680mm, 3U, additional to the UPS power module
Combined Rack AllocationWith one listed 3U bank: 5U for6000VA; 6U for10000VA, before additional clearance and accessories
Installation SupportAllow for separate heavy power and battery modules, suitable shelf/rail support, ventilation and cable access
Environment
Operating Temperature0–40°C
Operating HumidityUp to 95% RH, non-condensing
AltitudeUp to 2000m at 40°C; up to 3000m at 35°C, per manufacturer conditions
Acoustic NoiseBelow 50dB at 1m, per manufacturer conditions
追加商品
Ablerex BBC20J0000 外部バッテリーモジュール、背面接続を示していない 3U 外観イラスト
-31%予約注文新着
お気に入りに追加 比較に追加
ブランド: Ablerex

Ablerex BBC20J0000 外部バッテリーモジュール

通常価格 $2,181.82 SGD セール価格$1,500.00 SGD
Ablerex CY504B SNMP UPS Network Management Card - ACE Peripherals
-31%新着
お気に入りに追加 比較に追加
ブランド: Ablerex

Ablerex CY504B SNMP UPS Network Management Card

通常価格 $436.36 SGD セール価格$300.00 SGD
Ablerex MPDU-250 Maintenance Bypass PDU - ACE Peripherals Ablerex MPDU-250 Maintenance Bypass PDU - ACE Peripherals
-31%新着
お気に入りに追加 比較に追加
ブランド: Ablerex

Ablerex MPDU-250 Maintenance Bypass PDU

通常価格 $1,181.82 SGD セール価格$812.50 SGD

最近見た商品