WD Ultrastar DC SN Series Enterprise Data Center PCIe NVMe SSD
Enterprise NVMe Storage for Data That Needs to Stay Available WD Ultrastar DC SN Series enterprise SSDs give compatible servers and storage platforms fast access to the datasets behind cloud services, virtual machines and data-intensive applications. The SN655 platform combines PCIe Gen4 NVMe performance with TLC NAND, dual-port support and enterprise data protection. It is designed for read-intensive capacity storage, where responsive access, predictable service and efficient use of drive bays matter alongside capacity. Match the SSD to the host and write workload to build a storage layer that can grow with the application. Highlights Responsive Access to Enterprise Data PCIe Gen4 NVMe architecture with BiCS5 3D TLC NAND. Family performance reaches up to 6800MB/s sequential reads and 1.1 million random-read IOPS, depending on configuration. Protection and Redundant Access Dual-port support for qualified redundant storage paths and failover designs. Power-loss protection and end-to-end data-path protection. Designed for Managed Infrastructure U.3 enclosure with supported NVMe U.2 backplane compatibility. NVMe-MI management, Instant Secure Erase and defined endurance limits. Key Features Read-Intensive Performance for Active DatasetsCloud services and shared applications depend on timely access to stored information. The PCIe Gen4 interface and NVMe controller give the SN655 architecture the bandwidth and low-latency access needed for compatible enterprise storage. Sequential transfers suit large data movements, while random-read performance matters when applications request many smaller pieces of information. Select the ratings that match the workload; sustained performance and latency vary by drive configuration and host. A Storage Foundation for Cloud and Scale-Out PlatformsThe platform is designed for environments such as object and file storage, virtualisation, software-defined storage and distributed databases. Its capacity-oriented TLC design helps place substantial working datasets in an established enterprise drive format. For analytics, AI and machine-learning infrastructure, the SSD provides storage for the growing datasets that applications need to read and process. The complete server, storage software and network determine the performance delivered to those applications. Dual-Port Connectivity for Resilient Storage DesignsDual-port support gives a qualified storage platform more than one access path to the drive. Used with suitable controllers, backplanes and host software, this supports redundancy and failover when a path is unavailable. It is particularly useful where access continuity forms part of the storage design. Confirm platform support for the intended port mode so that the drive, enclosure and software work together as a complete availability solution. Drive-Level Protection for Important DataPower-loss protection helps the SSD handle unexpected interruptions, while end-to-end data-path protection supports integrity as data moves through the drive. These enterprise features are valuable in systems serving business applications and shared storage. Use them alongside appropriate system power protection, monitoring and tested backups. The drive protects its own data path; application recovery and wider service availability also depend on the rest of the infrastructure. Endurance That Supports Workload PlanningThe published endurance rating is one drive write per day over five years under the manufacturer’s stated random-write and JESD workloads. Use that rating to compare the application’s expected write traffic with the drive’s intended use, including maintenance and background activity. Monitor remaining flash life during service. The limited warranty ends at five years or when one percent of flash life remains, whichever occurs first, so both service time and wear matter. Management and Controlled Drive RetirementNVMe-MI support provides a management interface for compatible enterprise platforms. The listed ISE configurations also support Instant Secure Erase for an appropriate drive-retirement or reuse process. Check how the server or storage tools expose health information, firmware maintenance and erasure functions. Build these capabilities into normal operating procedures so that installation, monitoring and eventual decommissioning are planned together. U.3 Installation with Supported U.2 CompatibilityA 15mm-high, 2.5-inch U.3 enclosure fits qualified enterprise NVMe bays and supports compatible NVMe U.2 backplanes. Check the server’s drive support list, carrier, firmware and available clearance before installation. A bay with the same physical shape must also provide the correct NVMe connection and power. The dual-port and management features require the corresponding platform support. Power and Thermal Planning for Continuous ServiceDefined operating power modes help system designers plan the drive’s place in the server power budget. Suitable airflow through the enclosure is equally important during sustained activity. Monitor the drive’s composite temperature reading against its operating limit, and follow the manufacturer’s storage-temperature conditions when drives are held as spares. Published MTBF and failure-rate figures describe statistical populations and should complement monitoring and replacement planning. Summary WD Ultrastar DC SN Series combines enterprise NVMe performance with dual-port support, data protection and management features for compatible server and scale-out storage platforms. Its read-intensive design, established U.3 form factor and defined endurance help administrators match the drive to the workload and build a storage service suited to growing datasets.
Pickup available at 3005, Ubi Avenue 3, #01-88
일반적으로 2~4일 후 준비 완료
WD Ultrastar DC SN Series Enterprise Data Center PCIe NVMe SSD
제품 설명
Enterprise NVMe Storage for Data That Needs to Stay Available
WD Ultrastar DC SN Series enterprise SSDs give compatible servers and storage platforms fast access to the datasets behind cloud services, virtual machines and data-intensive applications. The SN655 platform combines PCIe Gen4 NVMe performance with TLC NAND, dual-port support and enterprise data protection. It is designed for read-intensive capacity storage, where responsive access, predictable service and efficient use of drive bays matter alongside capacity. Match the SSD to the host and write workload to build a storage layer that can grow with the application.
Highlights
Responsive Access to Enterprise Data
- PCIe Gen4 NVMe architecture with BiCS5 3D TLC NAND.
- Family performance reaches up to 6800MB/s sequential reads and 1.1 million random-read IOPS, depending on configuration.
Protection and Redundant Access
- Dual-port support for qualified redundant storage paths and failover designs.
- Power-loss protection and end-to-end data-path protection.
Designed for Managed Infrastructure
- U.3 enclosure with supported NVMe U.2 backplane compatibility.
- NVMe-MI management, Instant Secure Erase and defined endurance limits.
Key Features
Read-Intensive Performance for Active Datasets
Cloud services and shared applications depend on timely access to stored information. The PCIe Gen4 interface and NVMe controller give the SN655 architecture the bandwidth and low-latency access needed for compatible enterprise storage. Sequential transfers suit large data movements, while random-read performance matters when applications request many smaller pieces of information. Select the ratings that match the workload; sustained performance and latency vary by drive configuration and host.
A Storage Foundation for Cloud and Scale-Out Platforms
The platform is designed for environments such as object and file storage, virtualisation, software-defined storage and distributed databases. Its capacity-oriented TLC design helps place substantial working datasets in an established enterprise drive format. For analytics, AI and machine-learning infrastructure, the SSD provides storage for the growing datasets that applications need to read and process. The complete server, storage software and network determine the performance delivered to those applications.
Dual-Port Connectivity for Resilient Storage Designs
Dual-port support gives a qualified storage platform more than one access path to the drive. Used with suitable controllers, backplanes and host software, this supports redundancy and failover when a path is unavailable. It is particularly useful where access continuity forms part of the storage design. Confirm platform support for the intended port mode so that the drive, enclosure and software work together as a complete availability solution.
Drive-Level Protection for Important Data
Power-loss protection helps the SSD handle unexpected interruptions, while end-to-end data-path protection supports integrity as data moves through the drive. These enterprise features are valuable in systems serving business applications and shared storage. Use them alongside appropriate system power protection, monitoring and tested backups. The drive protects its own data path; application recovery and wider service availability also depend on the rest of the infrastructure.
Endurance That Supports Workload Planning
The published endurance rating is one drive write per day over five years under the manufacturer’s stated random-write and JESD workloads. Use that rating to compare the application’s expected write traffic with the drive’s intended use, including maintenance and background activity. Monitor remaining flash life during service. The limited warranty ends at five years or when one percent of flash life remains, whichever occurs first, so both service time and wear matter.
Management and Controlled Drive Retirement
NVMe-MI support provides a management interface for compatible enterprise platforms. The listed ISE configurations also support Instant Secure Erase for an appropriate drive-retirement or reuse process. Check how the server or storage tools expose health information, firmware maintenance and erasure functions. Build these capabilities into normal operating procedures so that installation, monitoring and eventual decommissioning are planned together.
U.3 Installation with Supported U.2 Compatibility
A 15mm-high, 2.5-inch U.3 enclosure fits qualified enterprise NVMe bays and supports compatible NVMe U.2 backplanes. Check the server’s drive support list, carrier, firmware and available clearance before installation. A bay with the same physical shape must also provide the correct NVMe connection and power. The dual-port and management features require the corresponding platform support.
Power and Thermal Planning for Continuous Service
Defined operating power modes help system designers plan the drive’s place in the server power budget. Suitable airflow through the enclosure is equally important during sustained activity. Monitor the drive’s composite temperature reading against its operating limit, and follow the manufacturer’s storage-temperature conditions when drives are held as spares. Published MTBF and failure-rate figures describe statistical populations and should complement monitoring and replacement planning.
Summary
WD Ultrastar DC SN Series combines enterprise NVMe performance with dual-port support, data protection and management features for compatible server and scale-out storage platforms. Its read-intensive design, established U.3 form factor and defined endurance help administrators match the drive to the workload and build a storage service suited to growing datasets.
사양
WD Ultrastar DC SN Series Enterprise Data Center PCIe NVMe SSD
WD Ultrastar DC SN Series brings enterprise NVMe storage to compatible servers, cloud infrastructure and scale-out platforms. The SN655 design combines PCIe Gen4 performance, dual-port support and drive-level data protection in a U.3 enclosure. The specifications below cover the listed ISE configurations. Performance varies by drive configuration and workload; confirm host, firmware and backplane support for the intended installation.
| Specification | Details |
|---|---|
| Storage and Performance | |
| Drive type | Enterprise NVMe SSD for cloud and server storage |
| NAND | BiCS5 3D TLC NAND |
| Interface | PCIe Gen4 x4; NVMe 1.4b |
| Port capability | Single-port or dual-port operation |
| Sequential read / write | Read: up to 6800MB/s; write: up to 3700MB/s; 128KiB |
| Random read / write | Read: up to 1.1M IOPS; write: up to 135K IOPS; 4KiB |
| Read / write latency | Read: 78–125µs; write: 10–40µs |
| Physical Specifications | |
| Form factor | 2.5-inch U.3; 15mm height |
| Dimensions (L × W × H) | 100.45 × 69.85 × 15mm |
| Bare-drive weight | 147.3g; excludes packaging |
| Power and Operating Conditions | |
| Power supply | 12V DC, ±10% |
| Operating power modes | 16W; 20W default (typical) |
| Idle power | Less than 8W average |
| Operating temperature | 0–70°C; composite drive reading |
| Non-operating temperature | −40–85°C ambient |
| Data Protection and Reliability | |
| Endurance | 1 DWPD over 5 years; 4KiB 100% random-write / JESD 219 workloads |
| Power-loss protection | Supported |
| Data-path protection | End-to-end data-path protection |
| Security | Instant Secure Erase (ISE) |
| MTBF | 2.5 million hours (projected) |
| Annualised failure rate | 0.35% (projected) |
| Uncorrectable bit error rate | 1 in 10¹⁷ bits |
| Compatibility and Warranty | |
| Backplane support | NVMe U.3; backward compatible with supported NVMe U.2 backplanes |
| Management interface | NVMe-MI 1.1b |
| Sector formats | Variable sector sizes |
| Installation | Qualified enterprise NVMe host, backplane, firmware and cooling |
| Limited warranty | 5 years or 1% remaining flash life, whichever occurs first |
Performance figures are sustained manufacturer peaks and vary by capacity, host and workload. Read latency is an average at 4KiB, QD1. MTBF and AFR describe statistical populations, not individual drive life. For storage beyond three months, avoid temperatures above 40°C. Formatted usable capacity is lower than decimal marketed capacity.



