TP-Link TL-MC1400 14-Slot Rackmount Chassis
Bring compatible media converters into one organised rack The TP-Link TL-MC1400 consolidates up to 14 compatible MC-series media converters in a standard 19-inch, 2U chassis. Central power distribution and two cooling fans make it a practical foundation for a network cabinet with several fibre links. One power supply is installed, with an optional second supply supporting redundancy. Select the converter family carefully: this chassis provides 9V DC outputs for supported MC-series units, rather than the 5V supply used by the FC-series chassis. Highlights Space for a planned fibre installation 14 converter slots in a standard 19-inch, 2U chassis. Compatible converters are selected separately. Centralised power 14 × 9V DC/0.6A converter outputs. One installed supply; optional redundant supply available separately. Rack integration Two cooling fans support chassis ventilation. Compatible converter servicing without shutting down the complete chassis. Key Features Consolidate the conversion layer Several individual converters and their power adapters can become difficult to manage in a network cabinet. A compatible chassis puts the conversion layer into defined slots and centralises power distribution. The MC1400 holds up to 14 supported converters; each optical link still needs its own correctly matched endpoint and cable. Choose the correct converter family MC1400 is intended for supported MC-series converters with the appropriate 9V input. It is not the FC-series chassis. The FC1420 serves a different power arrangement, and similar converter dimensions do not prove electrical compatibility. Check the exact converter model and hardware version before fitting it. Plan power redundancy as an option The chassis is supplied with one power supply and can support an additional redundant supply. A second supply must be selected separately; the standard package does not include a complete two-supply configuration. If power continuity is required, plan the compatible redundant supply, upstream power and operational testing together. Keep cooling and maintenance accessible Two fans move air through the enclosure. Leave the ventilation path and service access clear, and plan the rack around the converter cables and fibre bend radii. Supported hot-swappable converter operation helps service individual links, but removing a converter still interrupts the link that it carries. Confirm the rack fit The chassis uses a standard 19-inch rack width and 2U height. Published enclosure depth differs between hardware documents, so confirm the supplied revision and usable rack depth when space is tight. The chassis is for a suitable indoor rack environment within its specified operating conditions. Summary TL-MC1400 gives a compatible MC-series fibre installation a defined rack layout with shared power and active cooling. Choose the converters around the optical design, confirm the exact chassis and converter compatibility, and add a second power supply separately where redundancy is required. Frequently Asked Questions Are the media converters included?ExpandCollapse No. The chassis provides slots and power for up to 14 compatible converters. Choose each converter separately around the Ethernet speed, fibre type, optical connector and far-end equipment. Can it power TL-FC111 or TL-FC311 converters?ExpandCollapse Do not use MC1400 for FC-series converters. Its outputs are 9V DC for supported MC-series units. FC-series chassis compatibility uses a different power arrangement and must be checked against the exact converter. Does the standard package include redundant power?ExpandCollapse No. One power supply is installed. Redundant operation requires a separately selected compatible second supply and an appropriate upstream power arrangement. Can a converter be removed while other links remain running?ExpandCollapse Supported converters are hot-swappable in the chassis, so the complete chassis need not be shut down for an individual change. The removed converter’s own network link will still be interrupted. How much rack space does it need?ExpandCollapse Allow standard 19-inch mounting width and 2U height, plus cable and ventilation clearance. Confirm the enclosure depth for the supplied hardware version if the rack has limited usable depth.
Maaaring kunin sa 3005, Ubi Avenue 3, #01-88
Karaniwang handa sa loob ng 2-4 na araw ng negosyo (hindi kasama ang mga pampublikong pista opisyal)
TP-Link TL-MC1400 14-Slot Rackmount Chassis
Paglalarawan
Bring compatible media converters into one organised rack
The TP-Link TL-MC1400 consolidates up to 14 compatible MC-series media converters in a standard 19-inch, 2U chassis. Central power distribution and two cooling fans make it a practical foundation for a network cabinet with several fibre links. One power supply is installed, with an optional second supply supporting redundancy. Select the converter family carefully: this chassis provides 9V DC outputs for supported MC-series units, rather than the 5V supply used by the FC-series chassis.
Highlights
Space for a planned fibre installation
- 14 converter slots in a standard 19-inch, 2U chassis.
- Compatible converters are selected separately.
Centralised power
- 14 × 9V DC/0.6A converter outputs.
- One installed supply; optional redundant supply available separately.
Rack integration
- Two cooling fans support chassis ventilation.
- Compatible converter servicing without shutting down the complete chassis.
Key Features
Consolidate the conversion layer
Several individual converters and their power adapters can become difficult to manage in a network cabinet. A compatible chassis puts the conversion layer into defined slots and centralises power distribution. The MC1400 holds up to 14 supported converters; each optical link still needs its own correctly matched endpoint and cable.
Choose the correct converter family
MC1400 is intended for supported MC-series converters with the appropriate 9V input. It is not the FC-series chassis. The FC1420 serves a different power arrangement, and similar converter dimensions do not prove electrical compatibility. Check the exact converter model and hardware version before fitting it.
Plan power redundancy as an option
The chassis is supplied with one power supply and can support an additional redundant supply. A second supply must be selected separately; the standard package does not include a complete two-supply configuration. If power continuity is required, plan the compatible redundant supply, upstream power and operational testing together.
Keep cooling and maintenance accessible
Two fans move air through the enclosure. Leave the ventilation path and service access clear, and plan the rack around the converter cables and fibre bend radii. Supported hot-swappable converter operation helps service individual links, but removing a converter still interrupts the link that it carries.
Confirm the rack fit
The chassis uses a standard 19-inch rack width and 2U height. Published enclosure depth differs between hardware documents, so confirm the supplied revision and usable rack depth when space is tight. The chassis is for a suitable indoor rack environment within its specified operating conditions.
Summary
TL-MC1400 gives a compatible MC-series fibre installation a defined rack layout with shared power and active cooling. Choose the converters around the optical design, confirm the exact chassis and converter compatibility, and add a second power supply separately where redundancy is required.
Frequently Asked Questions
Are the media converters included?
No. The chassis provides slots and power for up to 14 compatible converters. Choose each converter separately around the Ethernet speed, fibre type, optical connector and far-end equipment.
Can it power TL-FC111 or TL-FC311 converters?
Do not use MC1400 for FC-series converters. Its outputs are 9V DC for supported MC-series units. FC-series chassis compatibility uses a different power arrangement and must be checked against the exact converter.
Does the standard package include redundant power?
No. One power supply is installed. Redundant operation requires a separately selected compatible second supply and an appropriate upstream power arrangement.
Can a converter be removed while other links remain running?
Supported converters are hot-swappable in the chassis, so the complete chassis need not be shut down for an individual change. The removed converter’s own network link will still be interrupted.
How much rack space does it need?
Allow standard 19-inch mounting width and 2U height, plus cable and ventilation clearance. Confirm the enclosure depth for the supplied hardware version if the rack has limited usable depth.
Mga detalye
TP-Link TL-MC1400 14-Slot Rackmount Chassis
The TP-Link TL-MC1400 is a rack chassis for up to 14 supported MC-series media converters. It combines 9V DC power distribution with active cooling in a standard 19-inch, 2U format. Converter compatibility is electrical as well as mechanical, and the converters are purchased separately. The grouped specifications separate the installed power supply from optional redundancy. Confirm the supplied chassis revision and rack clearance before installation where enclosure depth is critical.
| Specification | Details |
|---|---|
| Chassis and Compatibility | |
| Converter capacity | 14 slots; compatible media converters purchased separately. |
| Supported family | Supported MC-series converters requiring the appropriate 9V input; verify exact model and hardware version. |
| Rack format | Standard 19-inch rackmount; 2U height. |
| Chassis width and height | 482mm wide × 86mm high; confirm depth for the supplied hardware revision. |
| Cooling | 2 fans. |
| Power and Service | |
| AC input | 100–240V AC, 50/60Hz. |
| Converter outputs | 14 × 9V DC/0.6A. |
| Installed power supply | 1 power supply included. |
| Redundant power | Compatible second supply optional and purchased separately. |
| Converter servicing | Supported hot-swappable converter installation; removing a converter interrupts its own link. |
| Environment | |
| Operating temperature | 0°C to 40°C |
| Storage temperature | −40°C to 70°C |
| Operating humidity | 10–90% RH non-condensing. |
| Package and Warranty | |
| Included equipment | Rack chassis, AC power cord, 14 retainer plates and installation guide. Media converters and optional second power supply separate. |
| Warranty | 5 years. |