{"product_id":"d-link-dis-100g-06p","title":"D-Link DIS-100G-06P 6-Port Gigabit Industrial Unmanaged PoE+ Switch","description":"\u003cdiv id=\"ace-d-link-dis-100g-06p-copy\"\u003e\n\u003cstyle\u003e\n#ace-d-link-dis-100g-06p-copy { font-family: inherit; color: inherit; }\n\/* Reuses the current ACE calculator FAQ disclosure treatment. Scope: this product FAQ only. *\/\n#ace-d-link-dis-100g-06p-copy .ace-article-faq { --ace-family-ink: #21352b; --ace-family-muted: #5b6961; --ace-family-line: #d3d9d5; --ace-family-soft: #f4f7f4; margin: 24px 0; padding: 0; background: transparent; font-family: inherit; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq details.ace-form-disclosure { margin: 0 0 12px; padding: 0; border: 1px solid var(--ace-family-line); border-radius: 12px; background: #fff; overflow: visible; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq details \u003e summary { display: flex; align-items: center; justify-content: space-between; gap: 16px; min-height: 56px; margin: 0; padding: 16px 20px; border-radius: 12px; background: var(--ace-family-soft); color: var(--ace-family-ink); font: inherit; font-size: 16px; font-weight: 600; line-height: 1.4; list-style: none; cursor: pointer; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq summary::-webkit-details-marker { display: none; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq summary::marker { content: ''; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq summary::before, #ace-d-link-dis-100g-06p-copy .ace-article-faq summary::after { content: none; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq details[open] \u003e summary { border-radius: 12px 12px 0 0; border-bottom: 0; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq h3.ace-form-title { display: flex; align-items: center; justify-content: space-between; gap: 16px; width: 100%; min-width: 0; margin: 0 !important; padding: 0; color: var(--ace-family-ink); font-family: inherit; font-size: 16px; font-weight: 600; line-height: 1.35; letter-spacing: normal; text-transform: none; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq .ace-form-title-text { display: flex; flex: 1 1 auto; min-width: 0; margin: 0; overflow-wrap: anywhere; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq .ace-form-toggle { display: inline-flex; align-items: center; gap: 10px; flex: 0 0 auto; margin: 0 0 0 auto; padding: 0; color: #55605a; font-size: 12px; line-height: 1.4; font-weight: 500; white-space: nowrap; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq details \u003e summary .ace-form-collapse { display: none; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq details[open] \u003e summary .ace-form-expand { display: none; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq details[open] \u003e summary .ace-form-collapse { display: inline; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq .ace-form-chevron { display: inline-block; width: 8px; height: 8px; margin: 0 2px 4px; border-bottom: 2px solid currentColor; border-right: 2px solid currentColor; transform: rotate(45deg); transition: transform .15s ease; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq details[open] \u003e summary .ace-form-chevron { transform: rotate(225deg); margin-bottom: 0; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq .ace-form-body { margin: 0; padding: 20px; min-width: 0; color: var(--ace-family-ink); font-size: 15px; line-height: 1.65; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq .ace-form-body \u003e p { margin: 0; line-height: 1.65; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq summary:focus-visible { outline: 3px solid #24731a; outline-offset: 3px; }\n@media (max-width: 640px) {\n  #ace-d-link-dis-100g-06p-copy .ace-article-faq details \u003e summary { padding: 14px 16px; gap: 12px; }\n  #ace-d-link-dis-100g-06p-copy .ace-article-faq h3.ace-form-title { gap: 12px; }\n  #ace-d-link-dis-100g-06p-copy .ace-article-faq .ace-form-body { padding: 16px; }\n  #ace-d-link-dis-100g-06p-copy .ace-article-faq .ace-form-toggle { font-size: 11px; gap: 8px; }\n}\n@media (prefers-reduced-motion: reduce) { #ace-d-link-dis-100g-06p-copy .ace-article-faq .ace-form-chevron { transition: none; } }\n\n\n#ace-d-link-dis-100g-06p-copy .ace-article-faq { width:100%; max-width:100%; box-sizing:border-box; }\n#ace-d-link-dis-100g-06p-copy .ace-article-faq .ace-form-body { border:0; box-shadow:none; }\n\u003c\/style\u003e\n\u003ch2\u003eReliable Connectivity Beyond the Office\u003c\/h2\u003e\n\u003cp\u003eThe DIS-100G-06P connects equipment in industrial cabinets, production areas and protected surveillance installations. 4 Gigabit Ethernet ports and two Gigabit SFP slots provide a practical mix of local copper connections and separately specified fibre links. Its fanless metal enclosure mounts on a DIN rail and supports operation from −40°C to 75°C.\u003c\/p\u003e\n\u003cp\u003eFour PoE+ ports supply up to 30W each within a 120W shared budget. Plug-and-play unmanaged operation keeps straightforward network extensions simple without introducing a switch-management interface.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003ch3\u003eIndustrial Connectivity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4 × 10\/100\/1000BASE-T PoE+ and 2 × Gigabit SFP slots.\u003c\/li\u003e\n\u003cli\u003e12 Gbps switching capacity and up to 8.92 Mpps forwarding.\u003c\/li\u003e\n\u003cli\u003eFanless DIN-rail design for industrial cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower and Installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual 48–55 V DC terminal-block inputs; suitable DC power supply required separately.\u003c\/li\u003e\n\u003cli\u003eUp to 120W shared PoE+ power and 30W per powered port.\u003c\/li\u003e\n\u003cli\u003eIP40 metal housing and −40°C to 75°C operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNetwork Operation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnmanaged operation without software configuration.\u003c\/li\u003e\n\u003cli\u003e6kV surge protection on copper Ethernet ports.\u003c\/li\u003e\n\u003cli\u003e5-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003eBuilt for Equipment Cabinets\u003c\/h3\u003e\n\u003cp\u003eA fanless enclosure avoids a cooling fan as an additional maintenance point. The specified −40°C to 75°C operating range supports installations beyond a temperature-controlled office. The IP40 rating is not a weatherproof outdoor rating: install the switch inside a suitable enclosure with the required grounding, ventilation and protection from water.\u003c\/p\u003e\n\u003ch3\u003eCopper Access With Fibre Reach\u003c\/h3\u003e\n\u003cp\u003e4 Gigabit copper ports connect local equipment while two SFP slots provide fibre connection choices. Select compatible transceivers, fibre type, wavelength and distance for both ends of the link. The slots operate at Gigabit speed; they are not 10GbE uplinks, and optical modules are purchased separately.\u003c\/p\u003e\n\u003ch3\u003ePlan the Power System\u003c\/h3\u003e\n\u003cp\u003eDual 48–55 V DC terminal-block inputs allow two suitable external power sources to be connected for redundancy. A power supply is not included. Size the supply for the switch and the intended PoE load, allowing appropriate headroom and temperature derating. Installation and protective grounding should follow the manufacturer instructions.\u003c\/p\u003e\n\u003ch3\u003ePower Devices Over the Network\u003c\/h3\u003e\n\u003cp\u003eIEEE 802.3af\/at support provides up to 30W per powered port within the shared 120W budget. Add the actual endpoint requirements rather than multiplying the maximum port rating by every port. Sufficient DC input power and suitable cabling are required; available power at the device also depends on the Ethernet standard and cable losses.\u003c\/p\u003e\n\u003ch3\u003eConnect Without Configuration\u003c\/h3\u003e\n\u003cp\u003eUnmanaged operation lets a straightforward network extension start without switch configuration. Auto MDI\/MDIX and auto-negotiation simplify compatible copper connections. Keep the topology free of accidental loops and provide network segmentation upstream when needed; this model does not replace the policy controls of a managed switch.\u003c\/p\u003e\n\u003ch3\u003eA Practical Industrial Installation\u003c\/h3\u003e\n\u003cp\u003eA compact DIN-rail installation suits organised equipment cabinets. Visible power and port indicators help with on-site checks, while Energy-Efficient Ethernet reduces consumption when compatible links are lightly used. Keep access to the terminals and fibre connections clear, and select cables and transceivers rated for the actual site conditions.\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eThe DIS-100G-06P is a compact industrial unmanaged switch for dependable Gigabit access with PoE+ power. Specify the DC supply, optics and protective installation alongside the switch so the complete network is ready for its environment.\u003c\/p\u003e\n\u003csection class=\"ace-article-faq\" aria-label=\"Frequently asked questions\"\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails class=\"ace-form-disclosure\" open\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eIs a Power Supply Included?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. This offer requires a separate suitable 48–55 V DC DC power supply. The source must cover the intended PoE load as well as the switch, with appropriate installation headroom.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eDoes This Switch Power Cameras or Access Points?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eYes, compatible IEEE 802.3af\/at devices can use the 4 powered copper ports, with up to 30W per port and a 120W shared budget.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan It Be Installed Outdoors?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eUse it inside a suitable protective cabinet. The IP40 enclosure is not weatherproof. The installation must meet the specified temperature and humidity conditions and include appropriate grounding.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eAre the Fibre Modules Included?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. The two Gigabit SFP slots accept separately selected compatible transceivers. Match fibre type, wavelength, distance and environmental rating at both ends.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan I Configure VLANs and Redundant Links?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eThis is an unmanaged switch without a configuration interface. Use suitable managed equipment upstream for VLAN policy and avoid accidental cable loops.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eWhat Does Dual Power Input Mean?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eTwo suitable 48–55 V DC supplies can be wired to the terminal inputs so one source can sustain operation if the other fails. The supplies are purchased separately and must be correctly rated for the complete load.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"D-Link","offers":[{"title":"Default Title","offer_id":44849026302011,"sku":"DIS-100G-06P","price":226.28,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0557\/4541\/3179\/files\/d-link-dis-100g-06p-6-port-gigabit-industrial-unmanaged-poe-switch-2136590.png?v=1793693948","url":"https:\/\/aceperipherals.com\/zh\/products\/d-link-dis-100g-06p","provider":"ACE Peripherals","version":"1.0","type":"link"}