{"product_id":"ubiquiti-ua-retrofit-hub-2","title":"Ubiquiti UA-Retrofit-Hub-2 Two-Door Access Controller","description":"\u003cdiv id=\"ace-ubiquiti-ua-retrofit-hub-2-copy\"\u003e \u003cstyle\u003e\n#ace-ubiquiti-ua-retrofit-hub-2-copy { font-family: Inter, Arial, sans-serif; color: inherit; }\n\/* Reuses the current ACE calculator FAQ disclosure treatment. Scope: this product FAQ only. *\/\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq { --ace-family-ink: #21352b; --ace-family-muted: #5b6961; --ace-family-line: #d3d9d5; --ace-family-soft: #f4f7f4; margin: 24px 0; padding: 0; background: transparent; font-family: Inter, Arial, sans-serif; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq details.ace-form-disclosure { margin: 0 0 12px; padding: 0; border: 1px solid var(--ace-family-line); border-radius: 12px; background: #fff; overflow: visible; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq details \u003e summary { display: flex; align-items: center; justify-content: space-between; gap: 16px; min-height: 56px; margin: 0; padding: 16px 20px; border-radius: 12px; background: var(--ace-family-soft); color: var(--ace-family-ink); font: inherit; font-size: 16px; font-weight: 600; line-height: 1.4; list-style: none; cursor: pointer; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq summary::-webkit-details-marker { display: none; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq summary::marker { content: ''; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq summary::before, #ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq summary::after { content: none; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq details[open] \u003e summary { border-radius: 12px 12px 0 0; border-bottom: 0; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq h3.ace-form-title { display: flex; align-items: center; justify-content: space-between; gap: 16px; width: 100%; min-width: 0; margin: 0 !important; padding: 0; color: var(--ace-family-ink); font-family: Inter, Arial, sans-serif; font-size: 16px; font-weight: 600; line-height: 1.35; letter-spacing: normal; text-transform: none; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq .ace-form-title-text { display: flex; flex: 1 1 auto; min-width: 0; margin: 0; overflow-wrap: anywhere; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq .ace-form-toggle { display: inline-flex; align-items: center; gap: 10px; flex: 0 0 auto; margin: 0 0 0 auto; padding: 0; color: #55605a; font-size: 12px; line-height: 1.4; font-weight: 500; white-space: nowrap; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq details \u003e summary .ace-form-collapse { display: none; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq details[open] \u003e summary .ace-form-expand { display: none; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq details[open] \u003e summary .ace-form-collapse { display: inline; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq .ace-form-chevron { display: inline-block; width: 8px; height: 8px; margin: 0 2px 4px; border-bottom: 2px solid currentColor; border-right: 2px solid currentColor; transform: rotate(45deg); transition: transform .15s ease; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq details[open] \u003e summary .ace-form-chevron { transform: rotate(225deg); margin-bottom: 0; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq .ace-form-body { margin: 0; padding: 20px; min-width: 0; color: var(--ace-family-ink); font-size: 15px; line-height: 1.65; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq .ace-form-body \u003e p { margin: 0; line-height: 1.65; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq summary:focus-visible { outline: 3px solid #24731a; outline-offset: 3px; }\n@media (max-width: 640px) {\n  #ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq details \u003e summary { padding: 14px 16px; gap: 12px; }\n  #ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq h3.ace-form-title { gap: 12px; }\n  #ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq .ace-form-body { padding: 16px; }\n  #ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq .ace-form-toggle { font-size: 11px; gap: 8px; }\n}\n@media (prefers-reduced-motion: reduce) { #ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq .ace-form-chevron { transition: none; } }\n\n\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq { width:100%; max-width:100%; box-sizing:border-box; }\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq .ace-form-body { border:0; box-shadow:none; }\n\n#ace-ubiquiti-ua-retrofit-hub-2-copy .ace-article-faq {width:100%;max-width:none;box-sizing:border-box;}\n\u003c\/style\u003e\n \n\u003ch2\u003eA Clear Upgrade Path for Existing Doors\u003c\/h2\u003e\n\u003cp\u003eBring existing door hardware into a more organised access system with the UniFi Retrofit Hub 2. This compact DC-powered controller supports two doors, compatible OSDP or Wiegand readers, and the inputs needed to understand exit requests and door position. It is designed for installations where the existing cabling and lock arrangement deserve a careful upgrade rather than a complete restart.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003ch3\u003eTwo Doors Under One Controller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports entry and exit control for up to two doors.\u003c\/li\u003e\n\u003cli\u003eManaged through UniFi Access with a published 10,000-user capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKeep Useful Existing Hardware\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports compatible Wiegand readers and UniFi Retrofit Readers.\u003c\/li\u003e\n\u003cli\u003eDedicated request-to-exit, door-position and emergency inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFlexible Lock Circuits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePowered 12 V\/24 V lock outputs or suitable dry-relay control.\u003c\/li\u003e\n\u003cli\u003eIncluded DIN-rail mounting for an organised indoor installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003eReuse With a Proper Assessment\u003c\/h3\u003e\n\u003cp\u003eWiegand and OSDP support gives the installation team a route for retaining compatible readers and suitable existing wiring. Reader type, cable distance and the lock circuit should be reviewed together. Reusing a cable does not automatically establish that every connected component is compatible.\u003c\/p\u003e\n\u003ch3\u003eManage Door Events Together\u003c\/h3\u003e\n\u003cp\u003eThe controller supports two doors with reader connections, exit-request inputs and door-position inputs, plus an emergency input. These connections let the access configuration reflect the doorway rather than only recording a credential presentation. UniFi Access provides the management layer for the configured system.\u003c\/p\u003e\n\u003ch3\u003eMatch the Lock Supply\u003c\/h3\u003e\n\u003cp\u003eThe controller accepts 12 V or 24 V DC. Powered lock outputs support 12 V at up to 1 A or 24 V at up to 0.5 A, while dry relays support compatible externally powered circuits within their rating. The lock type and its required fail-safe or fail-secure behaviour must be matched during installation.\u003c\/p\u003e\n\u003ch3\u003eUse the Correct Reader Family\u003c\/h3\u003e\n\u003cp\u003eCompatible Models: UniFi Retrofit Reader UA-Retrofit-Reader. The hub also supports compatible third-party Wiegand readers. The standard Retrofit Reader is available separately; check each intended reader protocol and wiring diagram before specifying additional devices.\u003c\/p\u003e\n\u003ch3\u003eKeep the Control Cabinet Tidy\u003c\/h3\u003e\n\u003cp\u003eThe 140 × 120 × 45 mm housing and included DIN-rail mount suit an indoor control cabinet. Two 10\/100 MbE RJ45 ports provide network connectivity. These are network interfaces, not a substitute for the controller’s required DC power supply.\u003c\/p\u003e\n\u003ch3\u003eAllow for the Complete System\u003c\/h3\u003e\n\u003cp\u003eA suitable DC supply, readers, locks, door contacts and exit devices are selected separately. Size the supply and cables for the connected loads, and follow the approved emergency-release and door-control design. The hub’s 50 W maximum consumption figure must not be confused with the rating of an individual lock output.\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eThe Retrofit Hub 2 provides a considered route to UniFi Access for existing doors. Its reader support, separate door inputs and flexible relay arrangements help the installation match the hardware already in place while keeping control and management together.\u003c\/p\u003e\n\u003csection class=\"ace-article-faq\" aria-label=\"Frequently asked questions\"\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails class=\"ace-form-disclosure\" open\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan It Control Two Doors?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eYes. It supports up to two doors, with reader, exit-request and door-position connections. The complete wiring and access configuration depend on the installation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eWill My Existing Wiegand Reader Work?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eIt supports compatible third-party Wiegand readers. Confirm the reader’s protocol, supply and connections before retaining it.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eIs the Power Supply Included?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eThe hub requires a suitable 12 V or 24 V DC supply selected for the system. Do not assume the optional power supply or door locks are included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan It Power a Door Lock?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eIts powered outputs support 12 V DC up to 1 A or 24 V DC up to 0.5 A. Suitable dry-relay control is also available within the stated rating; the lock and emergency-release design must be checked.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan I Install It Outdoors?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eThe controller is specified for indoor use. Install it in an appropriate protected indoor location and follow the published temperature and humidity limits.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Ubiquiti","offers":[{"title":"Default Title","offer_id":45004768804923,"sku":"UA-Retrofit-Hub-2","price":344.3,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0557\/4541\/3179\/files\/ubiquiti-ua-retrofit-hub-2-two-door-access-controller-7692021.png?v=1794995056","url":"https:\/\/aceperipherals.com\/products\/ubiquiti-ua-retrofit-hub-2","provider":"ACE Peripherals","version":"1.0","type":"link"}