{"product_id":"d-link-dis-s310lx","title":"D-Link DIS-S310LX Industrial 1GbE Single-Mode SFP Transceiver","description":"\u003cdiv id=\"ace-d-link-dis-s310lx-copy\"\u003e\n\u003cstyle\u003e\n#ace-d-link-dis-s310lx-copy { font-family: inherit; color: inherit; }\n\/* Reuses the current ACE calculator FAQ disclosure treatment. Scope: this product FAQ only. *\/\n#ace-d-link-dis-s310lx-copy .ace-article-faq { --ace-family-ink: #21352b; --ace-family-muted: #5b6961; --ace-family-line: #d3d9d5; --ace-family-soft: #f4f7f4; margin: 24px 0; padding: 0; background: transparent; font-family: inherit; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq details.ace-form-disclosure { margin: 0 0 12px; padding: 0; border: 1px solid var(--ace-family-line); border-radius: 12px; background: #fff; overflow: visible; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq details \u003e summary { display: flex; align-items: center; justify-content: space-between; gap: 16px; min-height: 56px; margin: 0; padding: 16px 20px; border-radius: 12px; background: var(--ace-family-soft); color: var(--ace-family-ink); font: inherit; font-size: 16px; font-weight: 600; line-height: 1.4; list-style: none; cursor: pointer; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq summary::-webkit-details-marker { display: none; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq summary::marker { content: ''; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq summary::before, #ace-d-link-dis-s310lx-copy .ace-article-faq summary::after { content: none; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq details[open] \u003e summary { border-radius: 12px 12px 0 0; border-bottom: 0; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq h3.ace-form-title { display: flex; align-items: center; justify-content: space-between; gap: 16px; width: 100%; min-width: 0; margin: 0 !important; padding: 0; color: var(--ace-family-ink); font-family: inherit; font-size: 16px; font-weight: 600; line-height: 1.35; letter-spacing: normal; text-transform: none; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq .ace-form-title-text { display: flex; flex: 1 1 auto; min-width: 0; margin: 0; overflow-wrap: anywhere; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq .ace-form-toggle { display: inline-flex; align-items: center; gap: 10px; flex: 0 0 auto; margin: 0 0 0 auto; padding: 0; color: #55605a; font-size: 12px; line-height: 1.4; font-weight: 500; white-space: nowrap; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq details \u003e summary .ace-form-collapse { display: none; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq details[open] \u003e summary .ace-form-expand { display: none; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq details[open] \u003e summary .ace-form-collapse { display: inline; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq .ace-form-chevron { display: inline-block; width: 8px; height: 8px; margin: 0 2px 4px; border-bottom: 2px solid currentColor; border-right: 2px solid currentColor; transform: rotate(45deg); transition: transform .15s ease; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq details[open] \u003e summary .ace-form-chevron { transform: rotate(225deg); margin-bottom: 0; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq .ace-form-body { margin: 0; padding: 20px; min-width: 0; color: var(--ace-family-ink); font-size: 15px; line-height: 1.65; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq .ace-form-body \u003e p { margin: 0; line-height: 1.65; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq summary:focus-visible { outline: 3px solid #24731a; outline-offset: 3px; }\n@media (max-width: 640px) {\n  #ace-d-link-dis-s310lx-copy .ace-article-faq details \u003e summary { padding: 14px 16px; gap: 12px; }\n  #ace-d-link-dis-s310lx-copy .ace-article-faq h3.ace-form-title { gap: 12px; }\n  #ace-d-link-dis-s310lx-copy .ace-article-faq .ace-form-body { padding: 16px; }\n  #ace-d-link-dis-s310lx-copy .ace-article-faq .ace-form-toggle { font-size: 11px; gap: 8px; }\n}\n@media (prefers-reduced-motion: reduce) { #ace-d-link-dis-s310lx-copy .ace-article-faq .ace-form-chevron { transition: none; } }\n\n\n#ace-d-link-dis-s310lx-copy .ace-article-faq { width:100%; max-width:100%; box-sizing:border-box; }\n#ace-d-link-dis-s310lx-copy .ace-article-faq .ace-form-body { border:0; box-shadow:none; }\n\u003c\/style\u003e\n\u003ch2\u003eFibre Connectivity Specified for the Link\u003c\/h2\u003e\n\u003cp\u003eThe DIS-S310LX is a 1GbE SFP optical transceiver for compatible network equipment. It uses a duplex LC connection and 9\/125 µm single-mode fibre to support a specified reach of up to 10 km. Its industrial temperature rating supports protected factory, infrastructure and surveillance cabinets.\u003c\/p\u003e\n\u003cp\u003eMatch the module to the host’s supported SFP port, fibre type and optical standard at both ends. The −40°C to 85°C operating range applies to the module; the whole installation must also stay within the ratings of the switch, cables and enclosure. A pluggable form factor does not by itself guarantee interoperability with every vendor or every port.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003ch3\u003eOptical Connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1GbE networking using an SFP module.\u003c\/li\u003e\n\u003cli\u003eDuplex LC fibre connection.\u003c\/li\u003e\n\u003cli\u003eSingle-Mode fibre; up to 10 km specified reach.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLink Specification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1310 nm optical wavelength.\u003c\/li\u003e\n\u003cli\u003eIEEE 802.3z; MSA and RoHS compliant.\u003c\/li\u003e\n\u003cli\u003eHot-pluggable module for supported equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Design\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature −40°C to 85°C.\u003c\/li\u003e\n\u003cli\u003e20 g module weight.\u003c\/li\u003e\n\u003cli\u003e5-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003eChoose the Right Optical Medium\u003c\/h3\u003e\n\u003cp\u003eThis module is designed for 9\/125 µm single-mode fibre. The link needs the correct cable, connectors and a matching optical specification at the other end. Assess the installed fibre and connector loss as well as route length before selecting the link.\u003c\/p\u003e\n\u003ch3\u003eMatch the Host Port\u003c\/h3\u003e\n\u003cp\u003eThe SFP form factor is intended for supported 1GbE equipment. Check the exact switch or adapter model, supported firmware, port mode and compatibility list. An SFP socket alone does not establish that every optical standard or module is supported.\u003c\/p\u003e\n\u003ch3\u003eA Defined Fibre Link\u003c\/h3\u003e\n\u003cp\u003eThe optical interface uses 1310 nm light with duplex LC connectors. Two fibre paths carry transmit and receive traffic. Match the optical standard and link budget at both ends; this is not a single-fibre bidirectional module, a copper adapter or a cable that converts incompatible Ethernet standards.\u003c\/p\u003e\n\u003ch3\u003eTemperature Rating Where It Matters\u003c\/h3\u003e\n\u003cp\u003eThe module operates from −40°C to 85°C. That wider industrial range is useful in protected equipment cabinets with variable temperatures. The switch, power system and fibre installation still need to be rated for the same site.\u003c\/p\u003e\n\u003ch3\u003eService a Supported Port\u003c\/h3\u003e\n\u003cp\u003eHot-pluggable construction allows insertion or replacement in equipment that supports the feature. Work on the affected link still interrupts that connection, so plan a maintenance window or a tested redundant path where necessary. Keep fibre end faces clean and use the protective caps when the module is not connected.\u003c\/p\u003e\n\u003ch3\u003ePlan the Complete Optical Connection\u003c\/h3\u003e\n\u003cp\u003eThe offer is an optical module. Fibre patch leads, a second compatible endpoint and any required switch or adapter are separate. Before deployment, confirm connector type, optical loss, fibre grade and the host compatibility matrix so the complete connection is specified rather than relying on the module’s headline distance alone.\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eThe DIS-S310LX gives supported 1GbE equipment a defined single-mode fibre connection with an industrial operating-temperature range. Select the correct host port, matching optical endpoint and fibre cable for a reliable installation.\u003c\/p\u003e\n\u003csection class=\"ace-article-faq\" aria-label=\"Frequently asked questions\"\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails class=\"ace-form-disclosure\" open\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eWhich Fibre Type Does It Use?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eUse 9\/125 µm single-mode fibre with duplex LC connectors. The manufacturer specifies a maximum reach of 10 km under the required link conditions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eWill It Work in Any Pluggable Port?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. Confirm the host explicitly supports this 1GbE SFP module and the required port mode. A physically similar socket does not guarantee compatibility.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eDoes It Use One Fibre Strand?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. It uses a duplex LC connection with separate transmit and receive fibre paths. It is not a single-fibre bidirectional module.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eIs It an Industrial-Temperature Module?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eYes. The specified operating range is −40°C to 85°C. The host and the rest of the installation must also suit the site.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan It Be Replaced While the Switch Is Powered?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eIt is hot pluggable when used in supported equipment. The affected link disconnects during replacement; plan maintenance or a redundant path if interruption matters.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eAre Fibre Cables Included?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. Fibre patch leads and the matching equipment or module at the other end are selected separately.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"D-Link","offers":[{"title":"Default Title","offer_id":41568055820347,"sku":"DIS-S310LX","price":158.19,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0557\/4541\/3179\/files\/dis-s310lx-official-01.png?v=1793682116","url":"https:\/\/aceperipherals.com\/ja\/products\/d-link-dis-s310lx","provider":"ACE Peripherals","version":"1.0","type":"link"}