{"product_id":"d-link-dem-410t","title":"D-Link DEM-410T 10GBASE-T SFP+ Copper Transceiver","description":"\u003cdiv id=\"ace-d-link-dem-410t-copy\"\u003e\n\u003cstyle\u003e\n#ace-d-link-dem-410t-copy { font-family: inherit; color: inherit; }\n\/* Reuses the current ACE calculator FAQ disclosure treatment. Scope: this product FAQ only. *\/\n#ace-d-link-dem-410t-copy .ace-article-faq { --ace-family-ink: #21352b; --ace-family-muted: #5b6961; --ace-family-line: #d3d9d5; --ace-family-soft: #f4f7f4; margin: 24px 0; padding: 0; background: transparent; font-family: inherit; }\n#ace-d-link-dem-410t-copy .ace-article-faq details.ace-form-disclosure { margin: 0 0 12px; padding: 0; border: 1px solid var(--ace-family-line); border-radius: 12px; background: #fff; overflow: visible; }\n#ace-d-link-dem-410t-copy .ace-article-faq details \u003e summary { display: flex; align-items: center; justify-content: space-between; gap: 16px; min-height: 56px; margin: 0; padding: 16px 20px; border-radius: 12px; background: var(--ace-family-soft); color: var(--ace-family-ink); font: inherit; font-size: 16px; font-weight: 600; line-height: 1.4; list-style: none; cursor: pointer; }\n#ace-d-link-dem-410t-copy .ace-article-faq summary::-webkit-details-marker { display: none; }\n#ace-d-link-dem-410t-copy .ace-article-faq summary::marker { content: ''; }\n#ace-d-link-dem-410t-copy .ace-article-faq summary::before, #ace-d-link-dem-410t-copy .ace-article-faq summary::after { content: none; }\n#ace-d-link-dem-410t-copy .ace-article-faq details[open] \u003e summary { border-radius: 12px 12px 0 0; border-bottom: 0; }\n#ace-d-link-dem-410t-copy .ace-article-faq h3.ace-form-title { display: flex; align-items: center; justify-content: space-between; gap: 16px; width: 100%; min-width: 0; margin: 0 !important; padding: 0; color: var(--ace-family-ink); font-family: inherit; font-size: 16px; font-weight: 600; line-height: 1.35; letter-spacing: normal; text-transform: none; }\n#ace-d-link-dem-410t-copy .ace-article-faq .ace-form-title-text { display: flex; flex: 1 1 auto; min-width: 0; margin: 0; overflow-wrap: anywhere; }\n#ace-d-link-dem-410t-copy .ace-article-faq .ace-form-toggle { display: inline-flex; align-items: center; gap: 10px; flex: 0 0 auto; margin: 0 0 0 auto; padding: 0; color: #55605a; font-size: 12px; line-height: 1.4; font-weight: 500; white-space: nowrap; }\n#ace-d-link-dem-410t-copy .ace-article-faq details \u003e summary .ace-form-collapse { display: none; }\n#ace-d-link-dem-410t-copy .ace-article-faq details[open] \u003e summary .ace-form-expand { display: none; }\n#ace-d-link-dem-410t-copy .ace-article-faq details[open] \u003e summary .ace-form-collapse { display: inline; }\n#ace-d-link-dem-410t-copy .ace-article-faq .ace-form-chevron { display: inline-block; width: 8px; height: 8px; margin: 0 2px 4px; border-bottom: 2px solid currentColor; border-right: 2px solid currentColor; transform: rotate(45deg); transition: transform .15s ease; }\n#ace-d-link-dem-410t-copy .ace-article-faq details[open] \u003e summary .ace-form-chevron { transform: rotate(225deg); margin-bottom: 0; }\n#ace-d-link-dem-410t-copy .ace-article-faq .ace-form-body { margin: 0; padding: 20px; min-width: 0; color: var(--ace-family-ink); font-size: 15px; line-height: 1.65; }\n#ace-d-link-dem-410t-copy .ace-article-faq .ace-form-body \u003e p { margin: 0; line-height: 1.65; }\n#ace-d-link-dem-410t-copy .ace-article-faq summary:focus-visible { outline: 3px solid #24731a; outline-offset: 3px; }\n@media (max-width: 640px) {\n  #ace-d-link-dem-410t-copy .ace-article-faq details \u003e summary { padding: 14px 16px; gap: 12px; }\n  #ace-d-link-dem-410t-copy .ace-article-faq h3.ace-form-title { gap: 12px; }\n  #ace-d-link-dem-410t-copy .ace-article-faq .ace-form-body { padding: 16px; }\n  #ace-d-link-dem-410t-copy .ace-article-faq .ace-form-toggle { font-size: 11px; gap: 8px; }\n}\n@media (prefers-reduced-motion: reduce) { #ace-d-link-dem-410t-copy .ace-article-faq .ace-form-chevron { transition: none; } }\n\n\n#ace-d-link-dem-410t-copy .ace-article-faq { width:100%; max-width:100%; box-sizing:border-box; }\n#ace-d-link-dem-410t-copy .ace-article-faq .ace-form-body { border:0; box-shadow:none; }\n\u003c\/style\u003e\n\u003ch2\u003eA Copper Connection for a Compatible 10GbE Slot\u003c\/h2\u003e\n\u003cp\u003eThe DEM-410T adds a 10GBASE-T connection to a compatible SFP+ host port. It is designed for short copper connections between supported network equipment. An RJ45 connection and 10 Gbps interface keep the required host and cable choice clear.\u003c\/p\u003e\n\u003cp\u003eThe specified link reach is up to 30 m over Cat6A at 10Gbps. Match the switch’s supported module revision, port power and cooling requirements before installation.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003ch3\u003eConnection Standard\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10GBASE-T at 10 Gbps.\u003c\/li\u003e\n\u003cli\u003eSFP+ module with RJ45 connector.\u003c\/li\u003e\n\u003cli\u003eUp to 30 m over Cat6A at 10Gbps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLink Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable Cat6A copper cable for 10Gbps operation.\u003c\/li\u003e\n\u003cli\u003eElectrical copper connection.\u003c\/li\u003e\n\u003cli\u003eCompatible host port and supported module revision required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHot-pluggable design in a supported host.\u003c\/li\u003e\n\u003cli\u003eMatch both ends and test the completed link.\u003c\/li\u003e\n\u003cli\u003e5-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003eChoose the Correct Host Interface\u003c\/h3\u003e\n\u003cp\u003eThis module uses the SFP+ form factor and the 10GBASE-T connection standard. Check the host’s exact compatibility list, supported speed and hardware revision. Similar-looking SFP, SFP+, QSFP+ and QSFP28 modules are not automatically interchangeable.\u003c\/p\u003e\n\u003ch3\u003eMatch the Cable to the Link\u003c\/h3\u003e\n\u003cp\u003eUse a suitable Cat6A connection for the specified 10Gbps reach. A copper module does not extend a 10GbE link to the ordinary 100 m channel length of a native 10GBASE-T switch port. Cable quality and the host requirements remain important.\u003c\/p\u003e\n\u003ch3\u003ePlan the Required Distance\u003c\/h3\u003e\n\u003cp\u003eThe published reach is up to 30 m over Cat6A at 10Gbps. This specification depends on suitable cable and supported host operation. Keep bend radius, termination quality and the actual link path within the cable and equipment requirements.\u003c\/p\u003e\n\u003ch3\u003eMake Maintenance More Practical\u003c\/h3\u003e\n\u003cp\u003eHot-pluggable construction allows a supported host to accept or release the module without powering down the chassis. Removing the module still interrupts the link that uses it. Schedule the work and provide a tested alternate path where that connection is carrying production traffic.\u003c\/p\u003e\n\u003ch3\u003eCheck the Complete Pair\u003c\/h3\u003e\n\u003cp\u003eThe remote connection must support 10GBASE-T at the intended speed. Check auto-negotiation and host behaviour before using a different speed; do not assume every SFP+ port supports every copper module.\u003c\/p\u003e\n\u003ch3\u003eInstall Within the Host Limits\u003c\/h3\u003e\n\u003cp\u003eThe module operating range is 0°C to 65°C; host may impose a lower limit. Copper SFP+ modules add heat inside the host. Verify permitted port population and the host’s ambient-temperature limits, which may be more restrictive than the module’s own rating. For DGS-3630-28TC and DGS-3630-52PC, D-Link specifies hardware A2 only, at most two modules per switch and ambient temperature no higher than 40°C. Other hosts require their own compatibility check.\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eThe DEM-410T provides a focused 10GBASE-T connection for a compatible SFP+ host. Specify the correct copper cable and host thermal limits with the module to build a link that suits the installation.\u003c\/p\u003e\n\u003csection class=\"ace-article-faq\" aria-label=\"Frequently asked questions\"\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails class=\"ace-form-disclosure\" open\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eWill It Work in Any Similar-Looking Slot?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. The host must explicitly support this SFP+ module, connection standard, speed and hardware revision. Check the switch or adapter compatibility list before ordering. For DGS-3630-28TC and DGS-3630-52PC, D-Link specifies hardware A2 only, at most two modules per switch and ambient temperature no higher than 40°C. Other hosts require their own compatibility check.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eWhich Cable Does It Need?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eUse suitable Cat6A copper cabling. The cable and remote interface must match the connection standard.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eWhat Is the Maximum Link Distance?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eUp to 30 m over suitable Cat6A cabling at 10Gbps, within the supported host and installation limits. The host may impose additional temperature or port-population restrictions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan It Be Fitted Without Turning Off the Switch?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eThe module is hot-pluggable in a supported host. Fitting or removing it can still interrupt that link, so plan maintenance around the traffic it carries.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan It Replace a Different Optical Standard?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eDo not assume so. This is an electrical copper module, not a fibre optic module. Host compatibility, power and heat limits must be checked.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eAre Connection Cables Included?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo connection cable is included. Select suitable Cat6A cabling separately and confirm the host-specific temperature and port-population restrictions for this copper SFP+ module.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"D-Link","offers":[{"title":"Default Title","offer_id":41567732531259,"sku":"DEM-410T","price":158.19,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0557\/4541\/3179\/products\/d-link-dem-410t-10gbase-t-copper-sfp-transceiver-910784.png?v=1702134715","url":"https:\/\/aceperipherals.com\/ja\/products\/d-link-dem-410t","provider":"ACE Peripherals","version":"1.0","type":"link"}