{"product_id":"d-link-dis-210g-06","title":"D-Link DIS-210G-06 6-Port Gigabit Industrial Managed Switch","description":"\u003cdiv id=\"ace-d-link-dis-210g-06-copy\"\u003e\n\u003cstyle\u003e\n#ace-d-link-dis-210g-06-copy { font-family: inherit; color: inherit; }\n\/* Reuses the current ACE calculator FAQ disclosure treatment. Scope: this product FAQ only. *\/\n#ace-d-link-dis-210g-06-copy .ace-article-faq { --ace-family-ink: #21352b; --ace-family-muted: #5b6961; --ace-family-line: #d3d9d5; --ace-family-soft: #f4f7f4; margin: 24px 0; padding: 0; background: transparent; font-family: inherit; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq details.ace-form-disclosure { margin: 0 0 12px; padding: 0; border: 1px solid var(--ace-family-line); border-radius: 12px; background: #fff; overflow: visible; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq details \u003e summary { display: flex; align-items: center; justify-content: space-between; gap: 16px; min-height: 56px; margin: 0; padding: 16px 20px; border-radius: 12px; background: var(--ace-family-soft); color: var(--ace-family-ink); font: inherit; font-size: 16px; font-weight: 600; line-height: 1.4; list-style: none; cursor: pointer; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq summary::-webkit-details-marker { display: none; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq summary::marker { content: ''; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq summary::before, #ace-d-link-dis-210g-06-copy .ace-article-faq summary::after { content: none; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq details[open] \u003e summary { border-radius: 12px 12px 0 0; border-bottom: 0; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq h3.ace-form-title { display: flex; align-items: center; justify-content: space-between; gap: 16px; width: 100%; min-width: 0; margin: 0 !important; padding: 0; color: var(--ace-family-ink); font-family: inherit; font-size: 16px; font-weight: 600; line-height: 1.35; letter-spacing: normal; text-transform: none; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq .ace-form-title-text { display: flex; flex: 1 1 auto; min-width: 0; margin: 0; overflow-wrap: anywhere; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq .ace-form-toggle { display: inline-flex; align-items: center; gap: 10px; flex: 0 0 auto; margin: 0 0 0 auto; padding: 0; color: #55605a; font-size: 12px; line-height: 1.4; font-weight: 500; white-space: nowrap; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq details \u003e summary .ace-form-collapse { display: none; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq details[open] \u003e summary .ace-form-expand { display: none; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq details[open] \u003e summary .ace-form-collapse { display: inline; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq .ace-form-chevron { display: inline-block; width: 8px; height: 8px; margin: 0 2px 4px; border-bottom: 2px solid currentColor; border-right: 2px solid currentColor; transform: rotate(45deg); transition: transform .15s ease; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq details[open] \u003e summary .ace-form-chevron { transform: rotate(225deg); margin-bottom: 0; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq .ace-form-body { margin: 0; padding: 20px; min-width: 0; color: var(--ace-family-ink); font-size: 15px; line-height: 1.65; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq .ace-form-body \u003e p { margin: 0; line-height: 1.65; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq summary:focus-visible { outline: 3px solid #24731a; outline-offset: 3px; }\n@media (max-width: 640px) {\n  #ace-d-link-dis-210g-06-copy .ace-article-faq details \u003e summary { padding: 14px 16px; gap: 12px; }\n  #ace-d-link-dis-210g-06-copy .ace-article-faq h3.ace-form-title { gap: 12px; }\n  #ace-d-link-dis-210g-06-copy .ace-article-faq .ace-form-body { padding: 16px; }\n  #ace-d-link-dis-210g-06-copy .ace-article-faq .ace-form-toggle { font-size: 11px; gap: 8px; }\n}\n@media (prefers-reduced-motion: reduce) { #ace-d-link-dis-210g-06-copy .ace-article-faq .ace-form-chevron { transition: none; } }\n\n\n#ace-d-link-dis-210g-06-copy .ace-article-faq { width:100%; max-width:100%; box-sizing:border-box; }\n#ace-d-link-dis-210g-06-copy .ace-article-faq .ace-form-body { border:0; box-shadow:none; }\n\u003c\/style\u003e\n\u003ch2\u003eManaged Control Where the Network Meets the Worksite\u003c\/h2\u003e\n\u003cp\u003eThe DIS-210G-06 connects equipment in industrial cabinets, production areas and protected surveillance installations. 4 Gigabit Ethernet ports and two Gigabit SFP slots provide a practical mix of local copper connections and separately specified fibre links. Its fanless metal enclosure mounts on a DIN rail and supports operation from −40°C to 75°C.\u003c\/p\u003e\n\u003cp\u003eThis data-only model suits devices with their own power supply. VLANs, ERPS, access controls and static routing add configuration and diagnostic tools for a planned industrial network.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003ch3\u003eIndustrial Connectivity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4 × 10\/100\/1000BASE-T and 2 × Gigabit SFP slots.\u003c\/li\u003e\n\u003cli\u003e12 Gbps switching capacity and up to 8.92 Mpps forwarding.\u003c\/li\u003e\n\u003cli\u003eFanless DIN-rail design for industrial cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower and Installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual 12–55 V DC terminal-block inputs; suitable DC power supply required separately.\u003c\/li\u003e\n\u003cli\u003eData-only ports do not supply PoE power.\u003c\/li\u003e\n\u003cli\u003eIP40 metal housing and −40°C to 75°C operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNetwork Operation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManaged VLAN, ERPS, security and static-routing functions.\u003c\/li\u003e\n\u003cli\u003e6kV surge protection on copper Ethernet ports.\u003c\/li\u003e\n\u003cli\u003e5-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003eBuilt for Equipment Cabinets\u003c\/h3\u003e\n\u003cp\u003eA fanless enclosure avoids a cooling fan as an additional maintenance point. The specified −40°C to 75°C operating range supports installations beyond a temperature-controlled office. The IP40 rating is not a weatherproof outdoor rating: install the switch inside a suitable enclosure with the required grounding, ventilation and protection from water.\u003c\/p\u003e\n\u003ch3\u003eCopper Access With Fibre Reach\u003c\/h3\u003e\n\u003cp\u003e4 Gigabit copper ports connect local equipment while two SFP slots provide fibre connection choices. Select compatible transceivers, fibre type, wavelength and distance for both ends of the link. The slots operate at Gigabit speed; they are not 10GbE uplinks, and optical modules are purchased separately.\u003c\/p\u003e\n\u003ch3\u003ePlan the Power System\u003c\/h3\u003e\n\u003cp\u003eDual 12–55 V DC terminal-block inputs allow two suitable external power sources to be connected for redundancy. A power supply is not included. Size the supply for the switch, with appropriate headroom and temperature derating. Installation and protective grounding should follow the manufacturer instructions.\u003c\/p\u003e\n\u003ch3\u003eSimple Data-Only Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe Ethernet ports transmit data and do not supply PoE power. Connect independently powered computers, controllers and network equipment, or provide a suitable separate injector for an endpoint that needs PoE. This keeps the model choice clear when the installation has its own equipment power system.\u003c\/p\u003e\n\u003ch3\u003eControl Traffic at the Edge\u003c\/h3\u003e\n\u003cp\u003e802.1Q VLANs separate services, while link aggregation, spanning-tree protocols and ERPS support a deliberately designed topology. Static routing connects selected networks locally. Configure and test redundancy before relying on it; multiple cables alone do not establish a resilient network or remove the need for an upstream firewall.\u003c\/p\u003e\n\u003ch3\u003eClearer Fault Finding\u003c\/h3\u003e\n\u003cp\u003eA browser interface and CLI provide configuration access. Cable diagnostics, logs and Ethernet OAM help a network administrator investigate connection problems, while supported access controls restrict use according to the site policy. Keep management credentials secure and plan maintenance access before the switch is installed in a cabinet.\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eThe DIS-210G-06 is a compact industrial managed switch for dependable Gigabit access. Specify the DC supply, optics and protective installation alongside the switch so the complete network is ready for its environment.\u003c\/p\u003e\n\u003csection class=\"ace-article-faq\" aria-label=\"Frequently asked questions\"\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails class=\"ace-form-disclosure\" open\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eIs a Power Supply Included?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. This offer requires a separate suitable 12–55 V DC DC power supply. Dual terminal inputs support a redundant-power arrangement when two suitable sources are provided.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eDoes This Switch Power Cameras or Access Points?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. This is the non-PoE model. Equipment needs its own power supply or a separately chosen compatible PoE injector.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan It Be Installed Outdoors?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eUse it inside a suitable protective cabinet. The IP40 enclosure is not weatherproof. The installation must meet the specified temperature and humidity conditions and include appropriate grounding.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eAre the Fibre Modules Included?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. The two Gigabit SFP slots accept separately selected compatible transceivers. Match fibre type, wavelength, distance and environmental rating at both ends.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan I Configure VLANs and Redundant Links?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eYes. This managed model supports VLANs, spanning tree, ERPS and static routing. Plan and test the network configuration before deployment.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-form-disclosure\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eWhat Does Dual Power Input Mean?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eTwo suitable 12–55 V DC supplies can be wired to the terminal inputs so one source can sustain operation if the other fails. The supplies are purchased separately and must be correctly rated for the complete load.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"D-Link","offers":[{"title":"Default Title","offer_id":44849029742651,"sku":"DIS-210G-06","price":226.28,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0557\/4541\/3179\/files\/d-link-dis-210g-06-6-port-gigabit-industrial-managed-switch-5687982.png?v=1793693948","url":"https:\/\/aceperipherals.com\/id\/products\/d-link-dis-210g-06","provider":"ACE Peripherals","version":"1.0","type":"link"}