{"product_id":"ablerex-atsp-216","title":"Ablerex ATS Plus-216 Automatic Transfer Switch","description":"\u003cdiv id=\"ace-ablerex-atsp-216-copy\"\u003e\n\u003cstyle\u003e\n\n#ace-ablerex-atsp-216-copy { font-family: Inter, Arial, sans-serif; color: inherit; }\n\n\/* Reuses the current ACE calculator FAQ disclosure treatment. Scope: this product FAQ only. *\/\n\n#ace-ablerex-atsp-216-copy .ace-article-faq { --ace-family-ink: #21352b; --ace-family-muted: #5b6961; --ace-family-line: #d3d9d5; --ace-family-soft: #f4f7f4; margin: 24px 0; padding: 0; background: transparent; font-family: Inter, Arial, sans-serif; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq details.ace-form-disclosure { margin: 0 0 12px; padding: 0; border: 1px solid var(--ace-family-line); border-radius: 12px; background: #fff; overflow: visible; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq details \u003e summary { display: flex; align-items: center; justify-content: space-between; gap: 16px; min-height: 56px; margin: 0; padding: 16px 20px; border-radius: 12px; background: var(--ace-family-soft); color: var(--ace-family-ink); font: inherit; font-size: 16px; font-weight: 600; line-height: 1.4; list-style: none; cursor: pointer; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq summary::-webkit-details-marker { display: none; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq summary::marker { content: ''; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq summary::before, #ace-ablerex-atsp-216-copy .ace-article-faq summary::after { content: none; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq details[open] \u003e summary { border-radius: 12px 12px 0 0; border-bottom: 0; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq h3.ace-form-title { display: flex; align-items: center; justify-content: space-between; gap: 16px; width: 100%; min-width: 0; margin: 0 !important; padding: 0; color: var(--ace-family-ink); font-family: Inter, Arial, sans-serif; font-size: 16px; font-weight: 600; line-height: 1.35; letter-spacing: normal; text-transform: none; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq .ace-form-title-text { display: flex; flex: 1 1 auto; min-width: 0; margin: 0; overflow-wrap: anywhere; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq .ace-form-toggle { display: inline-flex; align-items: center; gap: 10px; flex: 0 0 auto; margin: 0 0 0 auto; padding: 0; color: #55605a; font-size: 12px; line-height: 1.4; font-weight: 500; white-space: nowrap; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq details \u003e summary .ace-form-collapse { display: none; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq details[open] \u003e summary .ace-form-expand { display: none; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq details[open] \u003e summary .ace-form-collapse { display: inline; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq .ace-form-chevron { display: inline-block; width: 8px; height: 8px; margin: 0 2px 4px; border-bottom: 2px solid currentColor; border-right: 2px solid currentColor; transform: rotate(45deg); transition: transform .15s ease; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq details[open] \u003e summary .ace-form-chevron { transform: rotate(225deg); margin-bottom: 0; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq .ace-form-body { margin: 0; padding: 20px; min-width: 0; color: var(--ace-family-ink); font-size: 15px; line-height: 1.65; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq .ace-form-body \u003e p { margin: 0; line-height: 1.65; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq summary:focus-visible { outline: 3px solid #24731a; outline-offset: 3px; }\n\n@media (max-width: 640px) {\n\n  #ace-ablerex-atsp-216-copy .ace-article-faq details \u003e summary { padding: 14px 16px; gap: 12px; }\n\n  #ace-ablerex-atsp-216-copy .ace-article-faq h3.ace-form-title { gap: 12px; }\n\n  #ace-ablerex-atsp-216-copy .ace-article-faq .ace-form-body { padding: 16px; }\n\n  #ace-ablerex-atsp-216-copy .ace-article-faq .ace-form-toggle { font-size: 11px; gap: 8px; }\n\n}\n\n@media (prefers-reduced-motion: reduce) { #ace-ablerex-atsp-216-copy .ace-article-faq .ace-form-chevron { transition: none; } }\n\n\n\n\n\n#ace-ablerex-atsp-216-copy .ace-article-faq { width:100%; max-width:100%; box-sizing:border-box; }\n\n#ace-ablerex-atsp-216-copy .ace-article-faq .ace-form-body { border:0; box-shadow:none; }\n\n\n#ace-ablerex-atsp-216-copy .ace-article-faq {width:100%;max-width:none;box-sizing:border-box;}\n\u003c\/style\u003e\n\u003ch2\u003eTwo power sources for single-cord equipment\u003c\/h2\u003e\n\u003cp\u003eThe Ablerex ATS Plus-216, also identified as ATSP-216, connects suitable single-cord equipment to two independent power sources. If the primary source becomes unavailable, the automatic transfer function switches the supported load to the alternate source without overlapping the two supplies.\u003c\/p\u003e\n\u003cp\u003eThe 16A unit fits a 1U rack position and provides two IEC C20 inputs with eight C13 and one C19 output. Its typical transfer time is 8–12ms. Plan the load and its power-supply ride-through capability around that switching interval; an ATS does not add a battery.\u003c\/p\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003ch3\u003eSource flexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo independent input sources\u003c\/li\u003e\n\u003cli\u003eAutomatic transfer without source overlap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eA defined 16A arrangement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 × IEC C20 inputs\u003c\/li\u003e\n\u003cli\u003e8 × IEC C13 and 1 × IEC C19 output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRack-based control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1U 19-inch rack design\u003c\/li\u003e\n\u003cli\u003eLCD\/LED status display and communication interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003eGive a single-cord load an alternate source\u003c\/h3\u003e\n\u003cp\u003eA server or other supported device with one power lead can be supplied through the ATS from two suitable independent sources. This adds an alternate power path without changing the equipment into a dual-cord device. Two outlets on the same failing source do not provide independent source resilience.\u003c\/p\u003e\n\u003ch3\u003eUnderstand the transfer interval\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer specifies a typical switching interval of 8–12ms. This is a transfer function, not a zero-time battery inverter. Confirm that the connected equipment can tolerate the interval and that both sources are suitable for the configured voltage and frequency.\u003c\/p\u003e\n\u003ch3\u003eUse the outlets within the total rating\u003c\/h3\u003e\n\u003cp\u003eThe output bank contains eight IEC C13 sockets and one C19 socket. The total maximum input and output current is 16A, and individual connectors retain their own limits. Select the leads, upstream protection and connected loads as one electrical system.\u003c\/p\u003e\n\u003ch3\u003eCheck the power path at the rack\u003c\/h3\u003e\n\u003cp\u003eThe LCD and LED indications show source availability, status and alarm information. Standard communication interfaces include RS232, USB and dry contacts, with an option slot for supported additional communications. Optional SNMP or RS485 hardware is separate and must be matched to the unit.\u003c\/p\u003e\n\u003ch3\u003eA compact, defined installation\u003c\/h3\u003e\n\u003cp\u003eThe enclosure measures 440 × 44 × 275mm and occupies 1U. Allow room for the two source leads and the outgoing equipment cables. Commission the source settings, alarm behaviour and transfer function before relying on the installation.\u003c\/p\u003e\n\u003ch3\u003eCompatible Models\u003c\/h3\u003e\n\u003cp\u003eSuitable single-cord equipment in a correctly specified 16A, 200–240V-class installation. ATSP-216 is intended for the specified 1–3kVA power arrangements. Match equipment ride-through capability, two independent sources, connectors and protective devices before deployment.\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eATS Plus-216 provides a compact automatic transfer path for supported single-cord equipment. Use it where the two source supplies and the connected load have been properly specified, with its typical switching interval and 16A total limit accounted for.\u003c\/p\u003e\n\u003csection class=\"ace-article-faq\" aria-label=\"Frequently asked questions\"\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cdetails class=\"ace-form-disclosure\" name=\"ace-ablerex-atsp-216-copy-faq\" open\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eIs ATS Plus-216 a UPS?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. It switches a supported load between two suitable power sources. It does not contain a battery or create backup power when both sources are unavailable.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"ace-form-disclosure\" name=\"ace-ablerex-atsp-216-copy-faq\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eWhat are the input and output connections?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eThere are two IEC C20 inputs, eight IEC C13 outputs and one IEC C19 output. Match the leads and upstream protection to the installation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"ace-form-disclosure\" name=\"ace-ablerex-atsp-216-copy-faq\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eIs the transfer time zero?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eNo. The manufacturer specifies a typical transfer time of 8–12ms. Confirm that the connected equipment can ride through that switching interval.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"ace-form-disclosure\" name=\"ace-ablerex-atsp-216-copy-faq\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eCan I use two outlets from the same UPS as independent sources?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eTwo outlets from the same failing supply do not create independent source resilience. The design should provide two suitable independent sources for the intended use.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"ace-form-disclosure\" name=\"ace-ablerex-atsp-216-copy-faq\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eIs a network card included?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eSNMP and RS485 are optional communications. The standard interfaces are RS232, USB, five output dry contacts and a communication slot; a compatible network option is separate.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"ace-form-disclosure\" name=\"ace-ablerex-atsp-216-copy-faq\"\u003e\u003csummary\u003e\u003ch3 class=\"ace-form-title\"\u003e\n\u003cspan class=\"ace-form-title-text\"\u003eHow much rack space and current does it need?\u003c\/span\u003e\u003cspan class=\"ace-form-toggle\" aria-hidden=\"true\"\u003e\u003cspan class=\"ace-form-expand\"\u003eExpand\u003c\/span\u003e\u003cspan class=\"ace-form-collapse\"\u003eCollapse\u003c\/span\u003e\u003cspan class=\"ace-form-chevron\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\u003c\/summary\u003e\u003cdiv class=\"ace-form-body\"\u003e\u003cp\u003eThe unit occupies 1U and measures 440 × 44 × 275mm. The maximum input and output current is 16A, subject to connector, cable and protection limits.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Ablerex","offers":[{"title":"Default Title","offer_id":44874636755003,"sku":"6AT0000E01E32","price":928.57,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0557\/4541\/3179\/files\/ablerex-ats-plus-216-automatic-transfer-switch-6935695.png?v=1793867467","url":"https:\/\/aceperipherals.com\/id\/products\/ablerex-atsp-216","provider":"ACE Peripherals","version":"1.0","type":"link"}